Certificate holders

Subtype

DAIKIN ALTHERMA H HYBRID GAS 4KW

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Registration number
011-1W0293
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
DAIKIN ALTHERMA H HYBRID GAS 4KW
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

0,560 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 4

Models

EJHA04AV3 / EHY2KOMB28A
Configure model
Model name
EJHA04AV3 / EHY2KOMB28A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.83 kW

3.28 kW

El input

0.85 kW

1.29 kW

COP

4.49

2.56

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

128 %

Prated

5.20 kW

5.60 kW

SCOP

4.14

3.26

Tbiv

2 °C

2 °C

TOL

-5 °C

-3 °C

Pdh Tj = -7°C

0.01 kW

0.01 kW

COP Tj = -7°C

1.00

1.00

Pdh Tj = +2°C

2.80 kW

3.00 kW

COP Tj = +2°C

4.31

3.19

Pdh Tj = +7°C

3.40 kW

3.20 kW

COP Tj = +7°C

5.78

4.52

Pdh Tj = 12°C

3.90 kW

3.90 kW

COP Tj = 12°C

8.02

6.42

Pdh Tj = Tbiv

2.80 kW

3.00 kW

COP Tj = Tbiv

4.31

3.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.00 kW

2.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

2.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

33 °C

48 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.20 kW

5.60 kW

Annual energy consumption Qhe

2595 kWh

3524 kWh

EJHA04AV3 / EHY2KOMB32A
Configure model
Model name
EJHA04AV3 / EHY2KOMB32A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.83 kW

3.28 kW

El input

0.85 kW

1.29 kW

COP

4.49

2.56

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

128 %

Prated

5.20 kW

5.60 kW

SCOP

4.15

3.28

Tbiv

2 °C

2 °C

TOL

-5 °C

-3 °C

Pdh Tj = -7°C

0.01 kW

0.01 kW

COP Tj = -7°C

1.00

1.00

Pdh Tj = +2°C

2.80 kW

3.00 kW

COP Tj = +2°C

4.31

3.19

Pdh Tj = +7°C

3.40 kW

3.20 kW

COP Tj = +7°C

5.78

4.52

Pdh Tj = 12°C

3.90 kW

3.90 kW

COP Tj = 12°C

8.02

6.42

Pdh Tj = Tbiv

2.80 kW

3.00 kW

COP Tj = Tbiv

4.31

3.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.00 kW

2.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

2.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

33 °C

48 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.20 kW

5.60 kW

Annual energy consumption Qhe

2588 kWh

3511 kWh

EJHA04AV3 / NHY2KOMB28A
Configure model
Model name
EJHA04AV3 / NHY2KOMB28A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.83 kW

3.28 kW

El input

0.85 kW

1.29 kW

COP

4.49

2.56

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

128 %

Prated

5.20 kW

5.60 kW

SCOP

4.14

3.26

Tbiv

2 °C

2 °C

TOL

-5 °C

-3 °C

Pdh Tj = -7°C

0.01 kW

0.01 kW

COP Tj = -7°C

1.00

1.00

Pdh Tj = +2°C

2.80 kW

3.00 kW

COP Tj = +2°C

4.31

3.19

Pdh Tj = +7°C

3.40 kW

3.20 kW

COP Tj = +7°C

5.78

4.52

Pdh Tj = 12°C

3.90 kW

3.90 kW

COP Tj = 12°C

8.02

6.42

Pdh Tj = Tbiv

2.80 kW

3.00 kW

COP Tj = Tbiv

4.31

3.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.00 kW

2.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

2.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

33 °C

48 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.20 kW

5.60 kW

Annual energy consumption Qhe

2595 kWh

3524 kWh

EJHA04AV3 / NHY2KOMB32A
Configure model
Model name
EJHA04AV3 / NHY2KOMB32A
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.83 kW

3.28 kW

El input

0.85 kW

1.29 kW

COP

4.49

2.56

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

163 %

128 %

Prated

5.20 kW

5.60 kW

SCOP

4.15

3.28

Tbiv

2 °C

2 °C

TOL

-5 °C

-3 °C

Pdh Tj = -7°C

0.01 kW

0.01 kW

COP Tj = -7°C

1.00

1.00

Pdh Tj = +2°C

2.80 kW

3.00 kW

COP Tj = +2°C

4.31

3.19

Pdh Tj = +7°C

3.40 kW

3.20 kW

COP Tj = +7°C

5.78

4.52

Pdh Tj = 12°C

3.90 kW

3.90 kW

COP Tj = 12°C

8.02

6.42

Pdh Tj = Tbiv

2.80 kW

3.00 kW

COP Tj = Tbiv

4.31

3.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.00 kW

2.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.15

2.49

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

33 °C

48 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.20 kW

5.60 kW

Annual energy consumption Qhe

2588 kWh

3511 kWh