1,400 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.50 kW
5.00 kW
El input
1.84 kW
1.94 kW
COP
4.08
2.58
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
48 dB(A)
48 dB(A)
Sound power level outdoor
69 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
118 %
Prated
7.00 kW
6.00 kW
SCOP
3.97
3.02
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.80 kW
5.30 kW
COP Tj = -7°C
2.40
1.80
Pdh Tj = +2°C
3.50 kW
3.10 kW
COP Tj = +2°C
3.80
2.90
Pdh Tj = +7°C
2.30 kW
2.00 kW
COP Tj = +7°C
5.70
4.10
Pdh Tj = 12°C
2.40 kW
2.20 kW
COP Tj = 12°C
8.20
5.80
Pdh Tj = Tbiv
5.80 kW
5.30 kW
COP Tj = Tbiv
2.40
1.80
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.60 kW
4.90 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.00
1.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.90
0.90
WTOL
55 °C
55 °C
Poff
6 W
6 W
PTO
30 W
16 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
1.20 kW
Annual energy consumption Qhe
3375 kWh
3886 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
120 %
COP
3.00
Heating up time
01:45 h:min
Standby power input
32.0 W
Reference hot water temperature
54.0 °C
Mixed water at 40°C
249 l