Certificate holders

Subtype

Mega XL

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-SC0833-18 / Issue 3
Certification Body
RISE CERT
Subtype title
Mega XL
Driving energy
n/a
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

9,000 kg

Certification Date
10.04.2019
Testing basis
n/a
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Thermia Mega XL 2020
Configure model
Model name
Thermia Mega XL 2020
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

52.18 kW

48.32 kW

El input

11.09 kW

17.02 kW

COP

4.71

2.84

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

160 %

Prated

84.67 kW

79.00 kW

SCOP

5.25

4.21

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

84.67 kW

79.00 kW

COP Tj = +2°C

3.97

2.72

Pdh Tj = +7°C

54.43 kW

50.79 kW

COP Tj = +7°C

4.85

3.60

Pdh Tj = 12°C

24.19 kW

24.07 kW

COP Tj = 12°C

5.85

5.16

Pdh Tj = Tbiv

84.67 kW

79.00 kW

COP Tj = Tbiv

3.97

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

84.67 kW

79.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.97

2.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

21524 kWh

23056 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

165 %

Prated

84.67 kW

79.00 kW

SCOP

5.30

4.32

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

51.25 kW

48.52 kW

COP Tj = -7°C

5.06

3.85

Pdh Tj = +2°C

31.20 kW

29.11 kW

COP Tj = +2°C

5.81

4.83

Pdh Tj = +7°C

24.49 kW

24.11 kW

COP Tj = +7°C

5.85

5.20

Pdh Tj = 12°C

24.39 kW

24.22 kW

COP Tj = 12°C

5.66

5.27

Pdh Tj = Tbiv

84.67 kW

79.00 kW

COP Tj = Tbiv

3.97

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

84.67 kW

79.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.97

2.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

39378 kWh

45048 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

157 %

Prated

84.67 kW

79.00 kW

SCOP

5.17

4.13

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

74.90 kW

69.88 kW

COP Tj = -7°C

4.26

3.00

Pdh Tj = +2°C

45.59 kW

42.54 kW

COP Tj = +2°C

5.14

4.08

Pdh Tj = +7°C

29.31 kW

27.35 kW

COP Tj = +7°C

5.81

4.94

Pdh Tj = 12°C

24.37 kW

24.08 kW

COP Tj = 12°C

5.65

5.16

Pdh Tj = Tbiv

84.67 kW

79.00 kW

COP Tj = Tbiv

3.97

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

84.67 kW

79.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.97

2.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

33804 kWh

39457 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

69.37 kW

62.91 kW

El input

12.10 kW

16.47 kW

COP

5.73

3.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

278 %

204 %

Prated

66.39 kW

80.95 kW

SCOP

7.16

5.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

66.39 kW

80.95 kW

COP Tj = +2°C

5.65

3.71

Pdh Tj = +7°C

42.68 kW

52.04 kW

COP Tj = +7°C

7.02

4.65

Pdh Tj = 12°C

31.13 kW

31.03 kW

COP Tj = 12°C

7.58

6.27

Pdh Tj = Tbiv

66.39 kW

80.95 kW

COP Tj = Tbiv

5.65

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

66.39 kW

80.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.65

3.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

12392 kWh

20426 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

285 %

215 %

Prated

66.39 kW

80.95 kW

SCOP

7.32

5.57

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

40.18 kW

49.00 kW

COP Tj = -7°C

7.28

5.06

Pdh Tj = +2°C

31.09 kW

29.83 kW

COP Tj = +2°C

7.55

6.11

Pdh Tj = +7°C

31.30 kW

31.18 kW

COP Tj = +7°C

7.70

6.43

Pdh Tj = 12°C

31.16 kW

31.37 kW

COP Tj = 12°C

7.60

6.66

Pdh Tj = Tbiv

66.39 kW

80.95 kW

COP Tj = Tbiv

5.65

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

66.39 kW

80.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.65

3.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

22343 kWh

35849 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

277 %

210 %

Prated

66.39 kW

80.95 kW

SCOP

7.12

5.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

58.73 kW

71.61 kW

COP Tj = -7°C

6.01

4.08

Pdh Tj = +2°C

35.75 kW

43.59 kW

COP Tj = +2°C

7.29

5.37

Pdh Tj = +7°C

31.01 kW

28.02 kW

COP Tj = +7°C

7.49

6.28

Pdh Tj = 12°C

31.34 kW

31.22 kW

COP Tj = 12°C

7.74

6.48

Pdh Tj = Tbiv

66.39 kW

80.95 kW

COP Tj = Tbiv

5.65

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

66.39 kW

80.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.65

3.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

19268 kWh

30975 kWh

Thermia Mega XL
Configure model
Model name
Thermia Mega XL
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

52.18 kW

48.32 kW

El input

11.09 kW

17.02 kW

COP

4.71

2.84

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

202 %

160 %

Prated

84.67 kW

79.00 kW

SCOP

5.25

4.21

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

84.67 kW

79.00 kW

COP Tj = +2°C

3.97

2.72

Pdh Tj = +7°C

54.43 kW

50.79 kW

COP Tj = +7°C

4.85

3.60

Pdh Tj = 12°C

24.19 kW

24.07 kW

COP Tj = 12°C

5.85

5.16

Pdh Tj = Tbiv

84.67 kW

79.00 kW

COP Tj = Tbiv

3.97

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

84.67 kW

79.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.97

2.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

21524 kWh

23056 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

165 %

Prated

84.67 kW

79.00 kW

SCOP

5.30

4.32

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

51.25 kW

48.52 kW

COP Tj = -7°C

5.06

3.85

Pdh Tj = +2°C

31.20 kW

29.11 kW

COP Tj = +2°C

5.81

4.83

Pdh Tj = +7°C

24.49 kW

24.11 kW

COP Tj = +7°C

5.85

5.20

Pdh Tj = 12°C

24.39 kW

24.22 kW

COP Tj = 12°C

5.66

5.27

Pdh Tj = Tbiv

84.67 kW

79.00 kW

COP Tj = Tbiv

3.97

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

84.67 kW

79.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.97

2.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

39378 kWh

45048 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

157 %

Prated

84.67 kW

79.00 kW

SCOP

5.17

4.13

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

74.90 kW

69.88 kW

COP Tj = -7°C

4.26

3.00

Pdh Tj = +2°C

45.59 kW

42.54 kW

COP Tj = +2°C

5.14

4.08

Pdh Tj = +7°C

29.31 kW

27.35 kW

COP Tj = +7°C

5.81

4.94

Pdh Tj = 12°C

24.37 kW

24.08 kW

COP Tj = 12°C

5.65

5.16

Pdh Tj = Tbiv

84.67 kW

79.00 kW

COP Tj = Tbiv

3.97

2.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

84.67 kW

79.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.97

2.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

33804 kWh

39457 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

69.37 kW

62.91 kW

El input

12.10 kW

16.47 kW

COP

5.73

3.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

278 %

204 %

Prated

66.39 kW

80.95 kW

SCOP

7.16

5.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

66.39 kW

80.95 kW

COP Tj = +2°C

5.65

3.71

Pdh Tj = +7°C

42.68 kW

52.04 kW

COP Tj = +7°C

7.02

4.65

Pdh Tj = 12°C

31.13 kW

31.03 kW

COP Tj = 12°C

7.58

6.27

Pdh Tj = Tbiv

66.39 kW

80.95 kW

COP Tj = Tbiv

5.65

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

66.39 kW

80.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.65

3.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

12392 kWh

20426 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

285 %

215 %

Prated

66.39 kW

80.95 kW

SCOP

7.32

5.57

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

40.18 kW

49.00 kW

COP Tj = -7°C

7.28

5.06

Pdh Tj = +2°C

31.09 kW

29.83 kW

COP Tj = +2°C

7.55

6.11

Pdh Tj = +7°C

31.30 kW

31.18 kW

COP Tj = +7°C

7.70

6.43

Pdh Tj = 12°C

31.16 kW

31.37 kW

COP Tj = 12°C

7.60

6.66

Pdh Tj = Tbiv

66.39 kW

80.95 kW

COP Tj = Tbiv

5.65

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

66.39 kW

80.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.65

3.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

22343 kWh

35849 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

50 dB(A)

50 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

277 %

210 %

Prated

66.39 kW

80.95 kW

SCOP

7.12

5.40

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

58.73 kW

71.61 kW

COP Tj = -7°C

6.01

4.08

Pdh Tj = +2°C

35.75 kW

43.59 kW

COP Tj = +2°C

7.29

5.37

Pdh Tj = +7°C

31.01 kW

28.02 kW

COP Tj = +7°C

7.49

6.28

Pdh Tj = 12°C

31.34 kW

31.22 kW

COP Tj = 12°C

7.74

6.48

Pdh Tj = Tbiv

66.39 kW

80.95 kW

COP Tj = Tbiv

5.65

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

66.39 kW

80.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.65

3.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

65 °C

65 °C

Poff

9 W

9 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

19268 kWh

30975 kWh