Certificate holders

Subtype

RAS-6WH(V)RP2E

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-75
Certification Body
BRE
Subtype title
RAS-6WH(V)RP2E
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,100 kg

Certification Date
05.09.2025
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Testing laboratory
Centro de Ensayos, Innovación y Servicios (CEIS), ES
Generate PDF Export model CSV Download certificate
  • Number of models 8

Models

01. RAS-6WHVRP2E + RWM-6R3E - Heating Only
Configure model
Model name
01. RAS-6WHVRP2E + RWM-6R3E - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.22 kW

3.43 kW

COP

4.35

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

127 %

Prated

13.00 kW

14.00 kW

SCOP

4.48

3.26

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

12.40 kW

COP Tj = -7°C

2.91

2.09

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.00 kW

7.55 kW

COP Tj = +2°C

4.35

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.50 kW

4.85 kW

COP Tj = +7°C

5.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.23 kW

COP Tj = 12°C

8.04

6.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.50 kW

12.40 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.60 kW

Annual energy consumption Qhe

5991 kWh

8886 kWh

02. RAS-6WHVRP2E + RWM-6R3E - With Cooling Kit
Configure model
Model name
02. RAS-6WHVRP2E + RWM-6R3E - With Cooling Kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.22 kW

3.43 kW

COP

4.35

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.98 kW

3.54 kW

Cooling capacity

11.50

14.00

EER

2.89

3.95

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

11.50 kW

14.00 kW

SEER

4.49

7.46

Pdc Tj = 35°C

11.50 kW

14.00 kW

EER Tj = 35°C

2.89

3.95

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.50 kW

10.30 kW

EER Tj = 30°C

4.03

5.85

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.40 kW

6.29 kW

EER Tj = 25°C

4.94

8.45

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.68 kW

4.59 kW

EER Tj = 20°C

5.74

12.40

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1537 kWh

1126 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

128 %

Prated

13.00 kW

14.00 kW

SCOP

4.52

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

12.40 kW

COP Tj = -7°C

2.91

2.09

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.00 kW

7.55 kW

COP Tj = +2°C

4.35

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.50 kW

4.85 kW

COP Tj = +7°C

5.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.23 kW

COP Tj = 12°C

8.04

6.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.50 kW

12.40 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.60 kW

Annual energy consumption Qhe

5939 kWh

8834 kWh

05. RAS-6WHRP2E + RWM-6R3E - Heating Only
Configure model
Model name
05. RAS-6WHRP2E + RWM-6R3E - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.22 kW

3.43 kW

COP

4.35

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

127 %

Prated

13.00 kW

14.00 kW

SCOP

4.48

3.26

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

12.40 kW

COP Tj = -7°C

2.91

2.09

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.00 kW

7.55 kW

COP Tj = +2°C

4.35

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.50 kW

4.85 kW

COP Tj = +7°C

5.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.23 kW

COP Tj = 12°C

8.04

6.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.50 kW

12.40 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.60 kW

Annual energy consumption Qhe

5991 kWh

8886 kWh

06. RAS-6WHRP2E + RWM-6R3E - With Cooling Kit
Configure model
Model name
06. RAS-6WHRP2E + RWM-6R3E - With Cooling Kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.22 kW

3.43 kW

COP

4.35

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.98 kW

3.54 kW

Cooling capacity

11.50

14.00

EER

2.89

3.95

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

11.50 kW

14.00 kW

SEER

4.49

7.46

Pdc Tj = 35°C

11.50 kW

14.00 kW

EER Tj = 35°C

2.89

3.95

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.50 kW

10.30 kW

EER Tj = 30°C

4.03

5.85

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.40 kW

6.29 kW

EER Tj = 25°C

4.94

8.45

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.68 kW

4.59 kW

EER Tj = 20°C

5.74

12.40

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1537 kWh

1126 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

128 %

Prated

13.00 kW

14.00 kW

SCOP

4.52

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

12.40 kW

COP Tj = -7°C

2.91

2.09

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.00 kW

7.55 kW

COP Tj = +2°C

4.35

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.50 kW

4.85 kW

COP Tj = +7°C

5.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.23 kW

COP Tj = 12°C

8.04

6.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.50 kW

12.40 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.60 kW

Annual energy consumption Qhe

5939 kWh

8834 kWh

03. RAS-6WHVRP2E + RWD-6RW3E-220S(-K) - Heating Only
Configure model
Model name
03. RAS-6WHVRP2E + RWD-6RW3E-220S(-K) - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.22 kW

3.43 kW

COP

4.35

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

127 %

Prated

13.00 kW

14.00 kW

SCOP

4.48

3.26

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

12.40 kW

COP Tj = -7°C

2.91

2.09

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.00 kW

7.55 kW

COP Tj = +2°C

4.35

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.50 kW

4.85 kW

COP Tj = +7°C

5.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.23 kW

COP Tj = 12°C

8.04

6.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.50 kW

12.40 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.60 kW

Annual energy consumption Qhe

5991 kWh

8886 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.73

Heating up time

1:08 h:min

Standby power input

43.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

273 l

04. RAS-6WHVRP2E + RWD-6RW3E-220S(-K) - With Cooling Kit
Configure model
Model name
04. RAS-6WHVRP2E + RWD-6RW3E-220S(-K) - With Cooling Kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.22 kW

3.43 kW

COP

4.35

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.98 kW

3.54 kW

Cooling capacity

11.50

14.00

EER

2.89

3.95

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

11.50 kW

14.00 kW

SEER

4.49

7.46

Pdc Tj = 35°C

11.50 kW

14.00 kW

EER Tj = 35°C

2.89

3.95

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.50 kW

10.30 kW

EER Tj = 30°C

4.03

5.85

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.40 kW

6.29 kW

EER Tj = 25°C

4.94

8.45

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.68 kW

4.59 kW

EER Tj = 20°C

5.74

12.40

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1537 kWh

1126 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

128 %

Prated

13.00 kW

14.00 kW

SCOP

4.52

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

12.40 kW

COP Tj = -7°C

2.91

2.09

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.00 kW

7.55 kW

COP Tj = +2°C

4.35

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.50 kW

4.85 kW

COP Tj = +7°C

5.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.23 kW

COP Tj = 12°C

8.04

6.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.50 kW

12.40 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.60 kW

Annual energy consumption Qhe

5939 kWh

8834 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.73

Heating up time

1:08 h:min

Standby power input

43.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

273 l

07. RAS-6WHRP2E + RWD-6RW3E-220S(-K) - Heating Only
Configure model
Model name
07. RAS-6WHRP2E + RWD-6RW3E-220S(-K) - Heating Only
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.22 kW

3.43 kW

COP

4.35

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

127 %

Prated

13.00 kW

14.00 kW

SCOP

4.48

3.26

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

12.40 kW

COP Tj = -7°C

2.91

2.09

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.00 kW

7.55 kW

COP Tj = +2°C

4.35

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.50 kW

4.85 kW

COP Tj = +7°C

5.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.23 kW

COP Tj = 12°C

8.04

6.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.50 kW

12.40 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.60 kW

Annual energy consumption Qhe

5991 kWh

8886 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.73

Heating up time

1:08 h:min

Standby power input

43.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

273 l

08. RAS-6WHRP2E + RWD-6RW3E-220S(-K) - With Cooling Kit
Configure model
Model name
08. RAS-6WHRP2E + RWD-6RW3E-220S(-K) - With Cooling Kit
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.22 kW

3.43 kW

COP

4.35

2.68

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

3.98 kW

3.54 kW

Cooling capacity

11.50

14.00

EER

2.89

3.95

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

11.50 kW

14.00 kW

SEER

4.49

7.46

Pdc Tj = 35°C

11.50 kW

14.00 kW

EER Tj = 35°C

2.89

3.95

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.50 kW

10.30 kW

EER Tj = 30°C

4.03

5.85

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.40 kW

6.29 kW

EER Tj = 25°C

4.94

8.45

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.68 kW

4.59 kW

EER Tj = 20°C

5.74

12.40

Cdc Tj = 20 °C

0.900

0.900

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Annual energy consumption Qce

1537 kWh

1126 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

54 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

128 %

Prated

13.00 kW

14.00 kW

SCOP

4.52

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

12.40 kW

COP Tj = -7°C

2.91

2.09

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.00 kW

7.55 kW

COP Tj = +2°C

4.35

3.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.50 kW

4.85 kW

COP Tj = +7°C

5.82

4.34

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.10 kW

4.23 kW

COP Tj = 12°C

8.04

6.36

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.50 kW

12.40 kW

COP Tj = Tbiv

2.91

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.00 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

55 °C

55 °C

Poff

14 W

14 W

PTO

15 W

15 W

PSB

14 W

14 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

1.60 kW

Annual energy consumption Qhe

5939 kWh

8834 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

112 %

COP

2.73

Heating up time

1:08 h:min

Standby power input

43.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

273 l