Certificate holders

Subtype

RASM-6(V)TW2E

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-81
Certification Body
BRE
Subtype title
RASM-6(V)TW2E
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,200 kg

Certification Date
05.09.2025
Testing basis
041-K002-81
Testing laboratory
Centro de Ensayos, Innovación y Servicios (CEIS), ES
Generate PDF Export model CSV Download certificate
  • Number of models 16

Models

RASM-6VTW2E & ATW-CBX-01 - Heating Only
Configure model
Model name
RASM-6VTW2E & ATW-CBX-01 - Heating Only
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

131 %

Prated

13.00 kW

14.00 kW

SCOP

4.54

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5918 kWh

8646 kWh

RASM-6TW2E & ATW-CBX-01 - Heating Only
Configure model
Model name
RASM-6TW2E & ATW-CBX-01 - Heating Only
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

131 %

Prated

13.00 kW

14.00 kW

SCOP

4.54

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5918 kWh

8646 kWh

RASM-6VTW2E & HWM-W2E - Heating Only
Configure model
Model name
RASM-6VTW2E & HWM-W2E - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

131 %

Prated

13.00 kW

14.00 kW

SCOP

4.54

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5918 kWh

8646 kWh

RASM-6TW2E & HWM-W2E - Heating Only
Configure model
Model name
RASM-6TW2E & HWM-W2E - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

131 %

Prated

13.00 kW

14.00 kW

SCOP

4.54

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5918 kWh

8646 kWh

RASM-6VTW2E & HWM-W2E-B - Heating Only
Configure model
Model name
RASM-6VTW2E & HWM-W2E-B - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

131 %

Prated

13.00 kW

14.00 kW

SCOP

4.54

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5918 kWh

8646 kWh

RASM-6TW2E & HWM-W2E-B - Heating Only
Configure model
Model name
RASM-6TW2E & HWM-W2E-B - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

131 %

Prated

13.00 kW

14.00 kW

SCOP

4.54

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.60 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.20 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.60 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5918 kWh

8598 kWh

RASM-6VTW2E & HWD-W2E-220S(-K) - Heating Only
Configure model
Model name
RASM-6VTW2E & HWD-W2E-220S(-K) - Heating Only
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

El input

4.81 kW

COP

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

Sound power level outdoor

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

131 %

Prated

14.00 kW

SCOP

3.35

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

11.90 kW

COP Tj = -7°C

2.00

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

7.20 kW

COP Tj = +2°C

2.99

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

5.20 kW

COP Tj = +7°C

5.37

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

5.00 kW

COP Tj = 12°C

7.69

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

11.90 kW

COP Tj = Tbiv

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

75 °C

Poff

13 W

PTO

13 W

PSB

13 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

3.10 kW

Annual energy consumption Qhe

8646 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118 %

COP

2.88

Heating up time

1:30 h:min

Standby power input

41.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

288 l

RASM-6TW2E & HWD-W2E-220S(-K) - Heating Only
Configure model
Model name
RASM-6TW2E & HWD-W2E-220S(-K) - Heating Only
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

El input

4.81 kW

COP

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

Sound power level outdoor

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

131 %

Prated

14.00 kW

SCOP

3.35

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

11.90 kW

COP Tj = -7°C

2.00

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

7.20 kW

COP Tj = +2°C

2.99

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

5.20 kW

COP Tj = +7°C

5.37

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

5.00 kW

COP Tj = 12°C

7.69

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

11.90 kW

COP Tj = Tbiv

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

75 °C

Poff

13 W

PTO

13 W

PSB

13 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

3.10 kW

Annual energy consumption Qhe

8646 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118 %

COP

2.88

Heating up time

1:30 h:min

Standby power input

41.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

288 l

RASM-6VTW2E & ATW-CBX-01 - With Cooling Kit
Configure model
Model name
RASM-6VTW2E & ATW-CBX-01 - With Cooling Kit
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.51 kW

4.18 kW

Cooling capacity

12.00

14.00

EER

2.66

3.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.00 kW

14.00 kW

SEER

3.80

5.86

Pdc Tj = 35°C

12.00 kW

14.00 kW

EER Tj = 35°C

2.66

3.35

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.90 kW

10.30 kW

EER Tj = 30°C

3.74

5.54

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.60 kW

6.60 kW

EER Tj = 25°C

4.14

6.98

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

4.20 kW

4.70 kW

EER Tj = 20°C

4.34

6.78

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

1892 kWh

1432 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

13.00 kW

14.00 kW

SCOP

4.58

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5870 kWh

8598 kWh

RASM-6TW2E & ATW-CBX-01 - With Cooling Kit
Configure model
Model name
RASM-6TW2E & ATW-CBX-01 - With Cooling Kit
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.51 kW

4.18 kW

Cooling capacity

12.00

14.00

EER

2.66

3.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.00 kW

14.00 kW

SEER

3.80

5.86

Pdc Tj = 35°C

12.00 kW

14.00 kW

EER Tj = 35°C

2.66

3.35

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.90 kW

10.30 kW

EER Tj = 30°C

3.74

5.54

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.60 kW

6.60 kW

EER Tj = 25°C

4.14

6.98

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

4.20 kW

4.70 kW

EER Tj = 20°C

4.34

6.78

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

1892 kWh

1432 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

13.00 kW

14.00 kW

SCOP

4.58

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5870 kWh

8598 kWh

RASM-6VTW2E & HWM-W2E - With Cooling Kit
Configure model
Model name
RASM-6VTW2E & HWM-W2E - With Cooling Kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.51 kW

4.18 kW

Cooling capacity

12.00

14.00

EER

2.66

3.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.00 kW

14.00 kW

SEER

3.80

5.86

Pdc Tj = 35°C

12.00 kW

14.00 kW

EER Tj = 35°C

2.66

3.35

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.90 kW

10.30 kW

EER Tj = 30°C

3.74

5.54

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.60 kW

6.60 kW

EER Tj = 25°C

4.14

6.98

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

4.20 kW

4.70 kW

EER Tj = 20°C

4.34

6.78

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

1892 kWh

1432 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

13.00 kW

14.00 kW

SCOP

4.58

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5870 kWh

8598 kWh

RASM-6TW2E & HWM-W2E - With Cooling Kit
Configure model
Model name
RASM-6TW2E & HWM-W2E - With Cooling Kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.51 kW

4.18 kW

Cooling capacity

12.00

14.00

EER

2.66

3.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.00 kW

14.00 kW

SEER

3.80

5.86

Pdc Tj = 35°C

12.00 kW

14.00 kW

EER Tj = 35°C

2.66

3.35

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.90 kW

10.30 kW

EER Tj = 30°C

3.74

5.54

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.60 kW

6.60 kW

EER Tj = 25°C

4.14

6.98

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

4.20 kW

4.70 kW

EER Tj = 20°C

4.34

6.78

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

1892 kWh

1432 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

13.00 kW

14.00 kW

SCOP

4.58

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5870 kWh

8598 kWh

RASM-6VTW2E & HWM-W2E-B - With Cooling Kit
Configure model
Model name
RASM-6VTW2E & HWM-W2E-B - With Cooling Kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.51 kW

4.18 kW

Cooling capacity

12.00

14.00

EER

2.66

3.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.00 kW

14.00 kW

SEER

3.80

5.86

Pdc Tj = 35°C

12.00 kW

14.00 kW

EER Tj = 35°C

2.66

3.35

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.90 kW

10.30 kW

EER Tj = 30°C

3.74

5.54

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.60 kW

6.60 kW

EER Tj = 25°C

4.14

6.98

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

4.20 kW

4.70 kW

EER Tj = 20°C

4.34

6.78

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

1892 kWh

1432 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

13.00 kW

14.00 kW

SCOP

4.58

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5870 kWh

8598 kWh

RASM-6TW2E & HWM-W2E-B - With Cooling Kit
Configure model
Model name
RASM-6TW2E & HWM-W2E-B - With Cooling Kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

14.00 kW

El input

3.41 kW

4.81 kW

COP

4.20

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.51 kW

4.18 kW

Cooling capacity

12.00

14.00

EER

2.66

3.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.00 kW

14.00 kW

SEER

3.80

5.86

Pdc Tj = 35°C

12.00 kW

14.00 kW

EER Tj = 35°C

2.66

3.35

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.90 kW

10.30 kW

EER Tj = 30°C

3.74

5.54

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.60 kW

6.60 kW

EER Tj = 25°C

4.14

6.98

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

4.20 kW

4.70 kW

EER Tj = 20°C

4.34

6.78

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

1892 kWh

1432 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

132 %

Prated

13.00 kW

14.00 kW

SCOP

4.58

3.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.90 kW

11.90 kW

COP Tj = -7°C

2.85

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.60 kW

7.20 kW

COP Tj = +2°C

4.25

2.99

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.00 kW

5.20 kW

COP Tj = +7°C

6.73

5.37

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.40 kW

5.00 kW

COP Tj = 12°C

9.21

7.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.90 kW

11.90 kW

COP Tj = Tbiv

2.85

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.20 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.90 kW

3.10 kW

Annual energy consumption Qhe

5870 kWh

8598 kWh

RASM-6VTW2E & HWD-W2E-220S(-K) - With Cooling Kit
Configure model
Model name
RASM-6VTW2E & HWD-W2E-220S(-K) - With Cooling Kit
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

El input

4.81 kW

COP

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.51 kW

4.18 kW

Cooling capacity

12.00

14.00

EER

2.66

3.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.00 kW

14.00 kW

SEER

3.80

5.86

Pdc Tj = 35°C

12.00 kW

14.00 kW

EER Tj = 35°C

2.66

3.35

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.90 kW

10.30 kW

EER Tj = 30°C

3.74

5.54

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.60 kW

6.60 kW

EER Tj = 25°C

4.14

6.98

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

4.20 kW

4.70 kW

EER Tj = 20°C

4.34

6.78

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

1892 kWh

1432 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

Sound power level outdoor

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

132 %

Prated

14.00 kW

SCOP

3.36

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

11.90 kW

COP Tj = -7°C

2.00

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

7.20 kW

COP Tj = +2°C

2.99

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

5.20 kW

COP Tj = +7°C

5.37

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

5.00 kW

COP Tj = 12°C

7.69

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

11.90 kW

COP Tj = Tbiv

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

75 °C

Poff

13 W

PTO

13 W

PSB

13 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

3.10 kW

Annual energy consumption Qhe

8598 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118 %

COP

2.88

Heating up time

1:30 h:min

Standby power input

41.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

288 l

RASM-6TW2E & HWD-W2E-220S(-K) - With Cooling Kit
Configure model
Model name
RASM-6TW2E & HWD-W2E-220S(-K) - With Cooling Kit
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.00 kW

El input

4.81 kW

COP

2.76

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

4.51 kW

4.18 kW

Cooling capacity

12.00

14.00

EER

2.66

3.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

12.00 kW

14.00 kW

SEER

3.80

5.86

Pdc Tj = 35°C

12.00 kW

14.00 kW

EER Tj = 35°C

2.66

3.35

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

8.90 kW

10.30 kW

EER Tj = 30°C

3.74

5.54

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

5.60 kW

6.60 kW

EER Tj = 25°C

4.14

6.98

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

4.20 kW

4.70 kW

EER Tj = 20°C

4.34

6.78

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

1892 kWh

1432 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

Sound power level outdoor

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

132 %

Prated

14.00 kW

SCOP

3.36

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

11.90 kW

COP Tj = -7°C

2.00

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

7.20 kW

COP Tj = +2°C

2.99

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

5.20 kW

COP Tj = +7°C

5.37

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

5.00 kW

COP Tj = 12°C

7.69

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

11.90 kW

COP Tj = Tbiv

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.75

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

75 °C

Poff

13 W

PTO

13 W

PSB

13 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

3.10 kW

Annual energy consumption Qhe

8598 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118 %

COP

2.88

Heating up time

1:30 h:min

Standby power input

41.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

288 l