0,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
4.00 kW
El input
0.85 kW
1.33 kW
COP
4.70
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
127 %
Prated
4.00 kW
4.00 kW
SCOP
4.50
3.25
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.54 kW
COP Tj = -7°C
2.64
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.15 kW
2.15 kW
COP Tj = +2°C
4.66
3.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.89 kW
2.86 kW
COP Tj = +7°C
6.89
4.94
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.96 kW
2.80 kW
COP Tj = 12°C
9.27
7.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.54 kW
3.54 kW
COP Tj = Tbiv
2.64
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.54 kW
3.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.46 kW
0.46 kW
Annual energy consumption Qhe
1836 kWh
2539 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
4.00 kW
El input
0.85 kW
1.33 kW
COP
4.70
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
127 %
Prated
4.00 kW
4.00 kW
SCOP
4.50
3.25
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.54 kW
COP Tj = -7°C
2.64
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.15 kW
2.15 kW
COP Tj = +2°C
4.66
3.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.89 kW
2.86 kW
COP Tj = +7°C
6.89
4.94
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.96 kW
2.80 kW
COP Tj = 12°C
9.27
7.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.54 kW
3.54 kW
COP Tj = Tbiv
2.64
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.54 kW
3.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.46 kW
0.46 kW
Annual energy consumption Qhe
1836 kWh
2539 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
4.00 kW
El input
0.85 kW
1.33 kW
COP
4.70
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
127 %
Prated
4.00 kW
4.00 kW
SCOP
4.50
3.25
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.54 kW
COP Tj = -7°C
2.64
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.15 kW
2.15 kW
COP Tj = +2°C
4.66
3.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.89 kW
2.86 kW
COP Tj = +7°C
6.89
4.94
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.96 kW
2.80 kW
COP Tj = 12°C
9.27
7.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.54 kW
3.54 kW
COP Tj = Tbiv
2.64
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.54 kW
3.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.46 kW
0.46 kW
Annual energy consumption Qhe
1836 kWh
2539 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
El input
1.33 kW
COP
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
Sound power level outdoor
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
127 %
Prated
4.00 kW
SCOP
3.25
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
3.54 kW
COP Tj = -7°C
2.18
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
2.15 kW
COP Tj = +2°C
3.12
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
2.86 kW
COP Tj = +7°C
4.94
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
2.80 kW
COP Tj = 12°C
7.28
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
3.54 kW
COP Tj = Tbiv
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
75 °C
Poff
13 W
PTO
13 W
PSB
13 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.46 kW
Annual energy consumption Qhe
2539 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.19
Heating up time
1:36 h:min
Standby power input
35.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
288 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
4.00 kW
El input
0.85 kW
1.33 kW
COP
4.70
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.44 kW
0.92 kW
Cooling capacity
4.00
4.00
EER
2.78
4.34
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
4.00 kW
4.00 kW
SEER
3.45
4.76
Pdc Tj = 35°C
4.00 kW
4.00 kW
EER Tj = 35°C
2.78
4.34
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
3.00 kW
3.00 kW
EER Tj = 30°C
3.42
4.80
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.80 kW
2.80 kW
EER Tj = 25°C
3.91
5.55
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.76 kW
3.26 kW
EER Tj = 20°C
4.74
6.57
Cdc Tj = 20 °C
0.900
0.900
Poff
13 W
13 W
PTO
0 W
0 W
PSB
13 W
13 W
PCK
0 W
0 W
Annual energy consumption Qce
696 kWh
504 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
130 %
Prated
4.00 kW
4.00 kW
SCOP
4.62
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.54 kW
COP Tj = -7°C
2.64
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.15 kW
2.15 kW
COP Tj = +2°C
4.66
3.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.89 kW
2.86 kW
COP Tj = +7°C
6.89
4.94
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.96 kW
2.80 kW
COP Tj = 12°C
9.27
7.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.54 kW
3.54 kW
COP Tj = Tbiv
2.64
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.54 kW
3.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.46 kW
0.46 kW
Annual energy consumption Qhe
1788 kWh
2492 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
4.00 kW
El input
0.85 kW
1.33 kW
COP
4.70
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.44 kW
0.92 kW
Cooling capacity
4.00
4.00
EER
2.78
4.34
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
4.00 kW
4.00 kW
SEER
3.45
4.76
Pdc Tj = 35°C
4.00 kW
4.00 kW
EER Tj = 35°C
2.78
4.34
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
3.00 kW
3.00 kW
EER Tj = 30°C
3.42
4.80
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.80 kW
2.80 kW
EER Tj = 25°C
3.91
5.55
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.76 kW
3.26 kW
EER Tj = 20°C
4.74
6.57
Cdc Tj = 20 °C
0.900
0.900
Poff
13 W
13 W
PTO
0 W
0 W
PSB
13 W
13 W
PCK
0 W
0 W
Annual energy consumption Qce
696 kWh
504 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
130 %
Prated
4.00 kW
4.00 kW
SCOP
4.62
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.54 kW
COP Tj = -7°C
2.64
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.15 kW
2.15 kW
COP Tj = +2°C
4.66
3.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.89 kW
2.86 kW
COP Tj = +7°C
6.89
4.94
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.96 kW
2.80 kW
COP Tj = 12°C
9.27
7.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.54 kW
3.54 kW
COP Tj = Tbiv
2.64
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.54 kW
3.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.46 kW
0.46 kW
Annual energy consumption Qhe
1788 kWh
2492 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
4.00 kW
El input
0.85 kW
1.33 kW
COP
4.70
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.44 kW
0.92 kW
Cooling capacity
4.00
4.00
EER
2.78
4.34
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
4.00 kW
4.00 kW
SEER
3.45
4.76
Pdc Tj = 35°C
4.00 kW
4.00 kW
EER Tj = 35°C
2.78
4.34
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
3.00 kW
3.00 kW
EER Tj = 30°C
3.42
4.80
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.80 kW
2.80 kW
EER Tj = 25°C
3.91
5.55
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.76 kW
3.26 kW
EER Tj = 20°C
4.74
6.57
Cdc Tj = 20 °C
0.900
0.900
Poff
13 W
13 W
PTO
0 W
0 W
PSB
13 W
13 W
PCK
0 W
0 W
Annual energy consumption Qce
696 kWh
504 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
130 %
Prated
4.00 kW
4.00 kW
SCOP
4.62
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
3.54 kW
COP Tj = -7°C
2.64
2.18
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.15 kW
2.15 kW
COP Tj = +2°C
4.66
3.12
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
2.89 kW
2.86 kW
COP Tj = +7°C
6.89
4.94
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
2.96 kW
2.80 kW
COP Tj = 12°C
9.27
7.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
3.54 kW
3.54 kW
COP Tj = Tbiv
2.64
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.54 kW
3.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.52
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
13 W
13 W
PSB
13 W
13 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.46 kW
0.46 kW
Annual energy consumption Qhe
1788 kWh
2492 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.00 kW
El input
1.33 kW
COP
3.00
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.44 kW
0.92 kW
Cooling capacity
4.00
4.00
EER
2.78
4.34
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
4.00 kW
4.00 kW
SEER
3.45
4.76
Pdc Tj = 35°C
4.00 kW
4.00 kW
EER Tj = 35°C
2.78
4.34
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
3.00 kW
3.00 kW
EER Tj = 30°C
3.42
4.80
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
2.80 kW
2.80 kW
EER Tj = 25°C
3.91
5.55
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
2.76 kW
3.26 kW
EER Tj = 20°C
4.74
6.57
Cdc Tj = 20 °C
0.900
0.900
Poff
13 W
13 W
PTO
0 W
0 W
PSB
13 W
13 W
PCK
0 W
0 W
Annual energy consumption Qce
696 kWh
504 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
Sound power level outdoor
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
130 %
Prated
4.00 kW
SCOP
3.32
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
3.54 kW
COP Tj = -7°C
2.18
Cdh Tj = -7 °C
0.900
Pdh Tj = +2°C
2.15 kW
COP Tj = +2°C
3.12
Cdh Tj = +2 °C
0.900
Pdh Tj = +7°C
2.86 kW
COP Tj = +7°C
4.94
Cdh Tj = +7 °C
0.900
Pdh Tj = 12°C
2.80 kW
COP Tj = 12°C
7.28
Cdh Tj = +12 °C
0.900
Pdh Tj = Tbiv
3.54 kW
COP Tj = Tbiv
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.54 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
WTOL
75 °C
Poff
13 W
PTO
13 W
PSB
13 W
PCK
0 W
Supplementary Heater: Type of energy input
Electricity
Supplementary Heater: PSUP
0.46 kW
Annual energy consumption Qhe
2492 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.19
Heating up time
1:36 h:min
Standby power input
35.0 W
Reference hot water temperature
52.0 °C
Mixed water at 40°C
288 l