Certificate holders

Subtype

RASM-2VTW2E

Certificate Holder
Johnson Controls-Hitachi AirConditioning Spain
Ronda Shimizu, 1. Pol. Ind. Can Torrella
08233 Vacarisses, Barcelona
Spain
Registration number
041-K002-76
Certification Body
BRE
Subtype title
RASM-2VTW2E
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,900 kg

Certification Date
05.09.2025
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Testing laboratory
Centro de Ensayos, Innovación y Servicios (CEIS), ES
Generate PDF Export model CSV Download certificate
  • Number of models 8

Models

RASM-2VTW2E & ATW-CBX-01 - Heating Only
Configure model
Model name
RASM-2VTW2E & ATW-CBX-01 - Heating Only
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

4.00 kW

El input

0.85 kW

1.33 kW

COP

4.70

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

127 %

Prated

4.00 kW

4.00 kW

SCOP

4.50

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.54 kW

COP Tj = -7°C

2.64

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.15 kW

2.15 kW

COP Tj = +2°C

4.66

3.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.89 kW

2.86 kW

COP Tj = +7°C

6.89

4.94

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.96 kW

2.80 kW

COP Tj = 12°C

9.27

7.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.54 kW

COP Tj = Tbiv

2.64

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.54 kW

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.46 kW

0.46 kW

Annual energy consumption Qhe

1836 kWh

2539 kWh

RASM-2VTW2E & HWM-W2E - Heating Only
Configure model
Model name
RASM-2VTW2E & HWM-W2E - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

4.00 kW

El input

0.85 kW

1.33 kW

COP

4.70

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

127 %

Prated

4.00 kW

4.00 kW

SCOP

4.50

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.54 kW

COP Tj = -7°C

2.64

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.15 kW

2.15 kW

COP Tj = +2°C

4.66

3.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.89 kW

2.86 kW

COP Tj = +7°C

6.89

4.94

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.96 kW

2.80 kW

COP Tj = 12°C

9.27

7.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.54 kW

COP Tj = Tbiv

2.64

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.54 kW

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.46 kW

0.46 kW

Annual energy consumption Qhe

1836 kWh

2539 kWh

RASM-2VTW2E & HWM-W2E-B - Heating Only
Configure model
Model name
RASM-2VTW2E & HWM-W2E-B - Heating Only
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

4.00 kW

El input

0.85 kW

1.33 kW

COP

4.70

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

127 %

Prated

4.00 kW

4.00 kW

SCOP

4.50

3.25

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.54 kW

COP Tj = -7°C

2.64

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.15 kW

2.15 kW

COP Tj = +2°C

4.66

3.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.89 kW

2.86 kW

COP Tj = +7°C

6.89

4.94

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.96 kW

2.80 kW

COP Tj = 12°C

9.27

7.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.54 kW

COP Tj = Tbiv

2.64

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.54 kW

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.46 kW

0.46 kW

Annual energy consumption Qhe

1836 kWh

2539 kWh

RASM-2VTW2E & HWD-W2E-220S(-K) - Heating Only
Configure model
Model name
RASM-2VTW2E & HWD-W2E-220S(-K) - Heating Only
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

El input

1.33 kW

COP

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

Sound power level outdoor

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

127 %

Prated

4.00 kW

SCOP

3.25

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

3.54 kW

COP Tj = -7°C

2.18

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

2.15 kW

COP Tj = +2°C

3.12

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

2.86 kW

COP Tj = +7°C

4.94

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

2.80 kW

COP Tj = 12°C

7.28

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

3.54 kW

COP Tj = Tbiv

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

75 °C

Poff

13 W

PTO

13 W

PSB

13 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.46 kW

Annual energy consumption Qhe

2539 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.19

Heating up time

1:36 h:min

Standby power input

35.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

288 l

RASM-2VTW2E & ATW-CBX-01 - With Cooling Kit
Configure model
Model name
RASM-2VTW2E & ATW-CBX-01 - With Cooling Kit
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

4.00 kW

El input

0.85 kW

1.33 kW

COP

4.70

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.44 kW

0.92 kW

Cooling capacity

4.00

4.00

EER

2.78

4.34

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

4.00 kW

SEER

3.45

4.76

Pdc Tj = 35°C

4.00 kW

4.00 kW

EER Tj = 35°C

2.78

4.34

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

3.00 kW

3.00 kW

EER Tj = 30°C

3.42

4.80

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

2.80 kW

2.80 kW

EER Tj = 25°C

3.91

5.55

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.76 kW

3.26 kW

EER Tj = 20°C

4.74

6.57

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

696 kWh

504 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

130 %

Prated

4.00 kW

4.00 kW

SCOP

4.62

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.54 kW

COP Tj = -7°C

2.64

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.15 kW

2.15 kW

COP Tj = +2°C

4.66

3.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.89 kW

2.86 kW

COP Tj = +7°C

6.89

4.94

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.96 kW

2.80 kW

COP Tj = 12°C

9.27

7.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.54 kW

COP Tj = Tbiv

2.64

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.54 kW

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.46 kW

0.46 kW

Annual energy consumption Qhe

1788 kWh

2492 kWh

RASM-2VTW2E & HWM-W2E - With Cooling Kit
Configure model
Model name
RASM-2VTW2E & HWM-W2E - With Cooling Kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

4.00 kW

El input

0.85 kW

1.33 kW

COP

4.70

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.44 kW

0.92 kW

Cooling capacity

4.00

4.00

EER

2.78

4.34

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

4.00 kW

SEER

3.45

4.76

Pdc Tj = 35°C

4.00 kW

4.00 kW

EER Tj = 35°C

2.78

4.34

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

3.00 kW

3.00 kW

EER Tj = 30°C

3.42

4.80

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

2.80 kW

2.80 kW

EER Tj = 25°C

3.91

5.55

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.76 kW

3.26 kW

EER Tj = 20°C

4.74

6.57

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

696 kWh

504 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

130 %

Prated

4.00 kW

4.00 kW

SCOP

4.62

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.54 kW

COP Tj = -7°C

2.64

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.15 kW

2.15 kW

COP Tj = +2°C

4.66

3.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.89 kW

2.86 kW

COP Tj = +7°C

6.89

4.94

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.96 kW

2.80 kW

COP Tj = 12°C

9.27

7.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.54 kW

COP Tj = Tbiv

2.64

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.54 kW

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.46 kW

0.46 kW

Annual energy consumption Qhe

1788 kWh

2492 kWh

RASM-2VTW2E & HWM-W2E-B - With Cooling Kit
Configure model
Model name
RASM-2VTW2E & HWM-W2E-B - With Cooling Kit
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

4.00 kW

El input

0.85 kW

1.33 kW

COP

4.70

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.44 kW

0.92 kW

Cooling capacity

4.00

4.00

EER

2.78

4.34

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

4.00 kW

SEER

3.45

4.76

Pdc Tj = 35°C

4.00 kW

4.00 kW

EER Tj = 35°C

2.78

4.34

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

3.00 kW

3.00 kW

EER Tj = 30°C

3.42

4.80

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

2.80 kW

2.80 kW

EER Tj = 25°C

3.91

5.55

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.76 kW

3.26 kW

EER Tj = 20°C

4.74

6.57

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

696 kWh

504 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

130 %

Prated

4.00 kW

4.00 kW

SCOP

4.62

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.54 kW

COP Tj = -7°C

2.64

2.18

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.15 kW

2.15 kW

COP Tj = +2°C

4.66

3.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.89 kW

2.86 kW

COP Tj = +7°C

6.89

4.94

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.96 kW

2.80 kW

COP Tj = 12°C

9.27

7.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.54 kW

3.54 kW

COP Tj = Tbiv

2.64

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.54 kW

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

13 W

13 W

PSB

13 W

13 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.46 kW

0.46 kW

Annual energy consumption Qhe

1788 kWh

2492 kWh

RASM-2VTW2E & HWD-W2E-220S(-K) - With Cooling Kit
Configure model
Model name
RASM-2VTW2E & HWD-W2E-220S(-K) - With Cooling Kit
Application
Heating + DHW
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.00 kW

El input

1.33 kW

COP

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.44 kW

0.92 kW

Cooling capacity

4.00

4.00

EER

2.78

4.34

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.00 kW

4.00 kW

SEER

3.45

4.76

Pdc Tj = 35°C

4.00 kW

4.00 kW

EER Tj = 35°C

2.78

4.34

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

3.00 kW

3.00 kW

EER Tj = 30°C

3.42

4.80

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

2.80 kW

2.80 kW

EER Tj = 25°C

3.91

5.55

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

2.76 kW

3.26 kW

EER Tj = 20°C

4.74

6.57

Cdc Tj = 20 °C

0.900

0.900

Poff

13 W

13 W

PTO

0 W

0 W

PSB

13 W

13 W

PCK

0 W

0 W

Annual energy consumption Qce

696 kWh

504 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

Sound power level outdoor

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

130 %

Prated

4.00 kW

SCOP

3.32

Tbiv

-7 °C

TOL

-10 °C

Pdh Tj = -7°C

3.54 kW

COP Tj = -7°C

2.18

Cdh Tj = -7 °C

0.900

Pdh Tj = +2°C

2.15 kW

COP Tj = +2°C

3.12

Cdh Tj = +2 °C

0.900

Pdh Tj = +7°C

2.86 kW

COP Tj = +7°C

4.94

Cdh Tj = +7 °C

0.900

Pdh Tj = 12°C

2.80 kW

COP Tj = 12°C

7.28

Cdh Tj = +12 °C

0.900

Pdh Tj = Tbiv

3.54 kW

COP Tj = Tbiv

2.18

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

1.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

WTOL

75 °C

Poff

13 W

PTO

13 W

PSB

13 W

PCK

0 W

Supplementary Heater: Type of energy input

Electricity

Supplementary Heater: PSUP

0.46 kW

Annual energy consumption Qhe

2492 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.19

Heating up time

1:36 h:min

Standby power input

35.0 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

288 l