2,990 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
12.80 kW
El input
4.08 kW
5.10 kW
COP
3.92
2.51
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
0 dB(A)
0 dB(A)
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
151 %
121 %
Prated
12.20 kW
10.30 kW
SCOP
3.86
3.10
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.79 kW
9.11 kW
COP Tj = -7°C
2.47
1.74
Pdh Tj = +2°C
6.57 kW
5.55 kW
COP Tj = +2°C
3.77
3.02
Pdh Tj = +7°C
8.24 kW
7.76 kW
COP Tj = +7°C
5.39
4.48
Pdh Tj = 12°C
5.14 kW
4.76 kW
COP Tj = 12°C
6.30
6.67
Pdh Tj = Tbiv
10.79 kW
9.11 kW
COP Tj = Tbiv
2.47
1.74
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.34 kW
8.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.07
1.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.96
0.97
WTOL
55 °C
55 °C
Poff
5 W
5 W
PTO
60 W
50 W
PSB
5 W
5 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.90 kW
2.20 kW
Annual energy consumption Qhe
6527 kWh
6857 kWh