Certificate holders

Subtype

AUREA 5

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-SC1489-17 / Issue 2
Certification Body
RISE CERT
Subtype title
AUREA 5
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,050 kg

Certification Date
n/a
Testing basis
n/a
Phase-out Date
09.04.2026
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AUREA 5 Phasing out on 09.04.2026
Configure model
Model name
AUREA 5
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Phase-out Date
09.04.2026

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.84 kW

4.10 kW

El input

1.20 kW

1.58 kW

COP

4.03

2.60

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

167 %

119 %

Prated

4.40 kW

4.40 kW

SCOP

4.25

3.06

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.89 kW

3.89 kW

COP Tj = -7°C

2.64

1.82

Pdh Tj = +2°C

2.37 kW

2.37 kW

COP Tj = +2°C

4.35

3.11

Pdh Tj = +7°C

2.16 kW

1.92 kW

COP Tj = +7°C

5.93

4.15

Pdh Tj = 12°C

1.15 kW

0.96 kW

COP Tj = 12°C

7.55

5.03

Pdh Tj = Tbiv

3.89 kW

3.89 kW

COP Tj = Tbiv

2.64

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.72 kW

3.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.57

1.52

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.84

0.89

WTOL

55 °C

55 °C

Poff

5 W

5 W

PTO

60 W

50 W

PSB

5 W

5 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.70 kW

1.00 kW

Annual energy consumption Qhe

2137 kWh

2973 kWh