Certificate holders

Subtype

NIBE AMS 10-16

Certificate Holder
Nibe AB
Box 14
S-28521 Markaryd
Sweden
Registration number
012-SC0606-18 / Issue 4
Certification Body
RISE CERT
Subtype title
NIBE AMS 10-16
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

4,000 kg

Certification Date
20.09.2018
Testing basis
EN 14511:2013, EN 14825:2016, EN 12102:2017.
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

NIBE AMS 10-16 + HBS05-16
Configure model
Model name
NIBE AMS 10-16 + HBS05-16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.03 kW

6.38 kW

El input

1.45 kW

2.04 kW

COP

4.85

3.13

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

134 %

Prated

14.50 kW

14.00 kW

SCOP

4.47

3.42

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.90 kW

12.50 kW

COP Tj = -7°C

2.96

2.01

Pdh Tj = +2°C

7.90 kW

7.60 kW

COP Tj = +2°C

4.37

3.29

Pdh Tj = +7°C

5.10 kW

4.90 kW

COP Tj = +7°C

5.58

4.68

Pdh Tj = 12°C

6.40 kW

6.80 kW

COP Tj = 12°C

6.99

6.51

Pdh Tj = Tbiv

13.40 kW

12.70 kW

COP Tj = Tbiv

2.86

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.50 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.97

0.98

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

25 W

16 W

PSB

15 W

15 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

3.00 kW

Annual energy consumption Qhe

6702 kWh

8431 kWh

NIBE AMS 10-16 + SHB10-16
Configure model
Model name
NIBE AMS 10-16 + SHB10-16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.03 kW

6.38 kW

El input

1.45 kW

2.04 kW

COP

4.85

3.13

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

62 dB(A)

62 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

134 %

Prated

14.50 kW

14.00 kW

SCOP

4.47

3.42

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.90 kW

12.50 kW

COP Tj = -7°C

2.96

2.01

Cdh Tj = -7 °C

0.98

0.98

Pdh Tj = +2°C

7.90 kW

7.60 kW

COP Tj = +2°C

4.37

3.29

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

5.10 kW

4.90 kW

COP Tj = +7°C

5.58

4.68

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

6.40 kW

6.80 kW

COP Tj = 12°C

6.99

6.51

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

13.40 kW

12.70 kW

COP Tj = Tbiv

2.86

1.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.50 kW

11.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.95

WTOL

65 °C

65 °C

Poff

2 W

2 W

PTO

25 W

25 W

PSB

15 W

15 W

PCK

35 W

35 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

3.00 kW

Annual energy consumption Qhe

6702 kWh

8431 kWh