Certificate holders

Subtype

Alféa Excellia HP A.I. Tri 17

Certificate Holder
Groupe Atlantic
44 boulevard des Etats-Unis
85000 La Roche Sur Yon
France
Registration number
012-SC0307-18 / issue 2
Certification Body
RISE CERT
Subtype title
Alféa Excellia HP A.I. Tri 17
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,800 kg

Certification Date
09.12.2022
Testing basis
EN 14511:2013, EN 16147:2017, EN 14825:2016, EN 12102:2013
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Alféa Excellia HP A.I. Tri 17
Configure model
Model name
Alféa Excellia HP A.I. Tri 17
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

17.11 kW

15.53 kW

El input

4.08 kW

5.52 kW

COP

4.19

2.81

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

130 %

Prated

18.00 kW

16.50 kW

SCOP

4.11

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

15.00 kW

COP Tj = -7°C

2.82

2.10

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

9.70 kW

9.00 kW

COP Tj = +2°C

4.13

3.32

Cdh Tj = +2 °C

0.960

0.980

Pdh Tj = +7°C

6.80 kW

6.30 kW

COP Tj = +7°C

5.01

4.23

Cdh Tj = +7 °C

0.930

0.970

Pdh Tj = 12°C

8.00 kW

7.70 kW

COP Tj = 12°C

6.64

5.95

Cdh Tj = +12 °C

0.920

0.960

Pdh Tj = Tbiv

16.00 kW

15.00 kW

COP Tj = Tbiv

2.82

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.90 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.76

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

97 W

49 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.10 kW

4.10 kW

Annual energy consumption Qhe

9059 kWh

10232 kWh

Alféa Excellia HP Duo A.I. Tri 17
Configure model
Model name
Alféa Excellia HP Duo A.I. Tri 17
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

17.11 kW

15.53 kW

El input

4.08 kW

5.52 kW

COP

4.19

2.81

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

67 dB(A)

67 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

161 %

130 %

Prated

18.00 kW

16.50 kW

SCOP

4.11

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

16.00 kW

15.00 kW

COP Tj = -7°C

2.82

2.10

Cdh Tj = -7 °C

0.980

0.990

Pdh Tj = +2°C

9.70 kW

9.00 kW

COP Tj = +2°C

4.13

3.32

Cdh Tj = +2 °C

0.960

0.980

Pdh Tj = +7°C

6.80 kW

6.30 kW

COP Tj = +7°C

5.01

4.23

Cdh Tj = +7 °C

0.930

0.970

Pdh Tj = 12°C

8.00 kW

7.70 kW

COP Tj = 12°C

6.64

5.95

Cdh Tj = +12 °C

0.920

0.960

Pdh Tj = Tbiv

16.00 kW

15.00 kW

COP Tj = Tbiv

2.82

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.90 kW

12.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.76

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.980

0.990

WTOL

60 °C

60 °C

Poff

16 W

16 W

PTO

97 W

49 W

PSB

19 W

19 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.10 kW

4.10 kW

Annual energy consumption Qhe

9059 kWh

10232 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

109 %

COP

2.56

Heating up time

00:54 h:min

Standby power input

48.0 W

Reference hot water temperature

54.2 °C

Mixed water at 40°C