2,700 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
11.38 kW
9.35 kW
El input
2.25 kW
2.84 kW
COP
5.06
3.29
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
136 %
Prated
12.50 kW
11.50 kW
SCOP
4.30
3.48
Tbiv
-17 °C
-18 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.60 kW
7.29 kW
COP Tj = -7°C
3.67
2.91
Cdh Tj = -7 °C
Pdh Tj = +2°C
4.70 kW
4.63 kW
COP Tj = +2°C
5.49
4.53
Cdh Tj = +2 °C
Pdh Tj = +7°C
4.87 kW
4.76 kW
COP Tj = +7°C
6.70
5.28
Cdh Tj = +7 °C
Pdh Tj = 12°C
5.58 kW
5.55 kW
COP Tj = 12°C
7.77
6.44
Cdh Tj = +12 °C
Pdh Tj = Tbiv
11.35 kW
10.87 kW
COP Tj = Tbiv
1.99
1.46
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.92 kW
4.57 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.99
1.51
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.990
WTOL
65 °C
65 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
7.58 kW
6.93 kW
Annual energy consumption Qhe
7158 kWh
8150 kWh
Pdh Tj = -15°C (if TOL<-20°C)
10.31
9.55
COP Tj = -15°C (if TOL<-20°C)
2.36
1.81
Cdh Tj = -15 °C
1.000
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
147 %
Prated
8.50 kW
8.50 kW
SCOP
4.92
3.77
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.76 kW
7.52 kW
COP Tj = -7°C
3.53
2.41
Pdh Tj = +2°C
4.49 kW
4.61 kW
COP Tj = +2°C
4.97
3.81
Pdh Tj = +7°C
4.81 kW
4.72 kW
COP Tj = +7°C
5.94
4.76
Pdh Tj = 12°C
5.56 kW
5.55 kW
COP Tj = 12°C
7.35
6.15
Pdh Tj = Tbiv
8.75 kW
8.66 kW
COP Tj = Tbiv
3.04
1.99
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.75 kW
8.66 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
65 °C
65 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
3567 kWh
4656 kWh