0,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.00 kW
5.00 kW
El input
0.99 kW
1.54 kW
COP
5.05
3.25
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
149 %
Prated
6.08 kW
6.10 kW
SCOP
4.88
3.81
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.38 kW
5.39 kW
COP Tj = -7°C
3.04
2.19
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
4.08 kW
3.27 kW
COP Tj = +2°C
4.76
3.75
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.49 kW
2.68 kW
COP Tj = +7°C
6.55
5.25
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
2.84 kW
2.64 kW
COP Tj = 12°C
9.89
7.14
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
5.38 kW
5.39 kW
COP Tj = Tbiv
3.04
2.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.07 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.88
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
38 W
38 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.01 kW
1.00 kW
Annual energy consumption Qhe
2574 kWh
3307 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.00 kW
7.00 kW
El input
1.40 kW
2.22 kW
COP
5.00
3.15
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
149 %
Prated
7.22 kW
6.94 kW
SCOP
4.98
3.79
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.39 kW
6.14 kW
COP Tj = -7°C
3.01
2.18
Cdh Tj = -7 °C
0.990
1.000
Pdh Tj = +2°C
4.21 kW
3.84 kW
COP Tj = +2°C
4.75
3.72
Cdh Tj = +2 °C
0.980
0.990
Pdh Tj = +7°C
2.57 kW
2.69 kW
COP Tj = +7°C
6.75
5.12
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
3.02 kW
2.83 kW
COP Tj = 12°C
11.00
7.64
Cdh Tj = +12 °C
0.950
0.960
Pdh Tj = Tbiv
6.39 kW
6.14 kW
COP Tj = Tbiv
3.01
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.99 kW
5.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
75 °C
75 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
38 W
38 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.23 kW
1.87 kW
Annual energy consumption Qhe
2996 kWh
3784 kWh