Certificate holders

Subtype

Thermia Calibra Eco Cool 8 BW

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-C700282 / Issue 1
Certification Body
RISE CERT
Subtype title
Thermia Calibra Eco Cool 8 BW
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R452B
Mass of Refrigerant

0,900 kg

Certification Date
15.04.2024
Testing basis
EN 14511:2022, EN 14825:2022, EN 16147:2017+A1:2022, EN 12102:2022
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Thermia Calibra Eco Cool 8 400V BW
Configure model
Model name
Thermia Calibra Eco Cool 8 400V BW
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.90 kW

6.21 kW

El input

1.06 kW

2.20 kW

COP

4.60

2.83

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

153 %

Prated

6.70 kW

6.24 kW

SCOP

5.65

4.01

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.70 kW

6.24 kW

COP Tj = +2°C

4.44

2.82

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

4.30 kW

4.01 kW

COP Tj = +7°C

5.47

3.61

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

2.54 kW

2.40 kW

COP Tj = 12°C

6.24

4.77

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1583 kWh

2076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.87

4.10

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.05 kW

3.77 kW

COP Tj = -7°C

5.68

3.81

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.47 kW

2.30 kW

COP Tj = +2°C

6.28

4.38

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.54 kW

2.41 kW

COP Tj = +7°C

6.30

4.93

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.53 kW

2.44 kW

COP Tj = 12°C

6.17

5.17

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2810 kWh

3748 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.57

4.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

5.52 kW

COP Tj = -7°C

4.73

3.12

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.61 kW

3.36 kW

COP Tj = +2°C

5.70

4.10

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.32 kW

2.16 kW

COP Tj = +7°C

5.96

4.80

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.54 kW

2.16 kW

COP Tj = 12°C

6.28

5.05

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2485 kWh

3139 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

 

Efficiency ηDHW

%

COP

 

Heating up time

h:min

Standby power input

W

Reference hot water temperature

°C

Mixed water at 40°C

l

Colder Climate

EN 16147

Declared load profile

 

Efficiency ηDHW

%

COP

 

Heating up time

h:min

Standby power input

W

Reference hot water temperature

°C

Mixed water at 40°C

l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

127 %

COP

3.14

Heating up time

02:13 h:min

Standby power input

25.0 W

Reference hot water temperature

52.2 °C

Mixed water at 40°C

234 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.88 kW

8.39 kW

El input

1.53 kW

2.36 kW

COP

5.82

3.56

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

308 %

207 %

Prated

8.86 kW

8.28 kW

SCOP

7.90

5.38

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.86 kW

8.28 kW

COP Tj = +2°C

5.91

3.62

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.70 kW

5.33 kW

COP Tj = +7°C

7.54

4.79

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

3.38 kW

3.24 kW

COP Tj = 12°C

8.97

6.53

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.86 kW

8.28 kW

COP Tj = Tbiv

5.91

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.86 kW

8.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.91

3.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1499 kWh

2058 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

327 %

218 %

Prated

8.86 kW

8.28 kW

SCOP

8.38

5.65

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.36 kW

5.01 kW

COP Tj = -7°C

8.01

5.10

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.27 kW

3.05 kW

COP Tj = +2°C

9.12

6.26

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.38 kW

3.26 kW

COP Tj = +7°C

9.10

6.80

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.37 kW

3.30 kW

COP Tj = 12°C

8.84

7.19

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.86 kW

8.28 kW

COP Tj = Tbiv

5.91

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.86 kW

8.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.91

3.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2606 kWh

3613 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

309 %

208 %

Prated

8.86 kW

8.28 kW

SCOP

7.93

5.41

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.84 kW

7.33 kW

COP Tj = -7°C

6.21

3.96

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.77 kW

4.46 kW

COP Tj = +2°C

8.15

5.46

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

3.07 kW

3.22 kW

COP Tj = +7°C

8.96

6.33

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.38 kW

3.27 kW

COP Tj = 12°C

9.07

6.89

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.86 kW

8.28 kW

COP Tj = Tbiv

5.91

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.86 kW

8.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.91

3.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2310 kWh

3165 kWh

Thermia Calibra Eco Cool 8 400V BW (with M-cycle)
Configure model
Model name
Thermia Calibra Eco Cool 8 400V BW (with M-cycle)
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
n/a
Off-peak product
n/a

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.90 kW

6.21 kW

El input

1.06 kW

2.20 kW

COP

4.60

2.83

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

218 %

153 %

Prated

6.70 kW

6.24 kW

SCOP

5.65

4.01

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.70 kW

6.24 kW

COP Tj = +2°C

4.44

2.82

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

4.30 kW

4.01 kW

COP Tj = +7°C

5.47

3.61

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

2.54 kW

2.40 kW

COP Tj = 12°C

6.24

4.77

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1583 kWh

2076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

227 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.87

4.10

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.05 kW

3.77 kW

COP Tj = -7°C

5.68

3.81

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.47 kW

2.30 kW

COP Tj = +2°C

6.28

4.38

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.54 kW

2.41 kW

COP Tj = +7°C

6.30

4.93

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.53 kW

2.44 kW

COP Tj = 12°C

6.17

5.17

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2810 kWh

3748 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

156 %

Prated

6.70 kW

6.24 kW

SCOP

5.57

4.10

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.92 kW

5.52 kW

COP Tj = -7°C

4.73

3.12

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.61 kW

3.36 kW

COP Tj = +2°C

5.70

4.10

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.32 kW

2.16 kW

COP Tj = +7°C

5.96

4.80

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.54 kW

2.16 kW

COP Tj = 12°C

6.28

5.05

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

6.70 kW

6.24 kW

COP Tj = Tbiv

4.44

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

6.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.44

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2485 kWh

3139 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

 

Efficiency ηDHW

%

COP

 

Heating up time

h:min

Standby power input

W

Reference hot water temperature

°C

Mixed water at 40°C

l

Colder Climate

EN 16147

Declared load profile

 

Efficiency ηDHW

%

COP

 

Heating up time

h:min

Standby power input

W

Reference hot water temperature

°C

Mixed water at 40°C

l

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

91 %

COP

2.16

Heating up time

02:02 h:min

Standby power input

25.3 W

Reference hot water temperature

52.0 °C

Mixed water at 40°C

217 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

8.88 kW

8.39 kW

El input

1.53 kW

2.36 kW

COP

5.82

3.56

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

308 %

207 %

Prated

8.86 kW

8.28 kW

SCOP

7.90

5.38

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.86 kW

8.28 kW

COP Tj = +2°C

5.91

3.62

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

5.70 kW

5.33 kW

COP Tj = +7°C

7.54

4.79

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

3.38 kW

3.24 kW

COP Tj = 12°C

8.97

6.53

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.86 kW

8.28 kW

COP Tj = Tbiv

5.91

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.86 kW

8.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.91

3.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1499 kWh

2058 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

327 %

218 %

Prated

8.86 kW

8.28 kW

SCOP

8.38

5.65

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.36 kW

5.01 kW

COP Tj = -7°C

8.01

5.10

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

3.27 kW

3.05 kW

COP Tj = +2°C

9.12

6.26

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.38 kW

3.26 kW

COP Tj = +7°C

9.10

6.80

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.37 kW

3.30 kW

COP Tj = 12°C

8.84

7.19

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.86 kW

8.28 kW

COP Tj = Tbiv

5.91

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.86 kW

8.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.91

3.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2606 kWh

3613 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

309 %

208 %

Prated

8.86 kW

8.28 kW

SCOP

7.93

5.41

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.84 kW

7.33 kW

COP Tj = -7°C

6.21

3.96

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.77 kW

4.46 kW

COP Tj = +2°C

8.15

5.46

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

3.07 kW

3.22 kW

COP Tj = +7°C

8.96

6.33

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

3.38 kW

3.27 kW

COP Tj = 12°C

9.07

6.89

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

8.86 kW

8.28 kW

COP Tj = Tbiv

5.91

3.62

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.86 kW

8.28 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.91

3.62

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

5 W

5 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2310 kWh

3165 kWh