DE DIETRICH ALEZIO S R 32 HYBRID GAZ 6/8 MR

Certificate Holder
BDR Thermea FR (DE DIETRICH)
57 rue de la Gare
67580 Mertzwiller
France
Registration number
007-DP0182
Certification Body
Kiwa Nederland B.V.
Subtype title
DE DIETRICH ALEZIO S R 32 HYBRID GAZ 6/8 MR
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,200 kg

Certification Date
08.03.2024
Testing basis
European KEYMARK Scheme for Heat Pumps (v9)
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

AWHPR 6 MR + MIV-S 4-8/H R32 + MCR 2 30 MI
Configure model
Model name
AWHPR 6 MR + MIV-S 4-8/H R32 + MCR 2 30 MI
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.40 kW

5.70 kW

El input

1.28 kW

1.97 kW

COP

5.00

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.10 kW

1.36 kW

Cooling capacity

6.50

7.00

EER

3.09

5.14

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.50 kW

7.00 kW

SEER

4.01

6.49

Pdc Tj = 35°C

6.50 kW

7.00 kW

EER Tj = 35°C

3.09

5.14

Pdc Tj = 30°C

4.90 kW

5.39 kW

EER Tj = 30°C

3.99

6.65

Pdc Tj = 25°C

3.10 kW

3.32 kW

EER Tj = 25°C

4.55

4.93

Pdc Tj = 20°C

1.37 kW

1.78 kW

EER Tj = 20°C

3.96

12.82

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Annual energy consumption Qce

973 kWh

647 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

132 %

Prated

6.50 kW

6.00 kW

SCOP

4.52

3.38

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.90 kW

5.50 kW

COP Tj = -7°C

3.16

2.22

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.50 kW

3.40 kW

COP Tj = +2°C

4.48

3.37

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.25 kW

2.10 kW

COP Tj = +7°C

5.61

4.07

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.50 kW

2.50 kW

COP Tj = 12°C

6.92

6.58

Cdh Tj = +12 °C

0.960

0.970

Pdh Tj = Tbiv

6.60 kW

5.50 kW

COP Tj = Tbiv

2.68

2.22

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.60 kW

5.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

1.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

2974 kWh

3667 kWh

AWHPR 8 MR + MIV-S 4-8/H R32 + MCR 2 30 MI
Configure model
Model name
AWHPR 8 MR + MIV-S 4-8/H R32 + MCR 2 30 MI
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.60 kW

8.00 kW

El input

1.59 kW

2.91 kW

COP

4.77

2.75

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.15 kW

1.45 kW

Cooling capacity

6.50

7.10

EER

3.02

4.88

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

6.50 kW

7.10 kW

SEER

4.43

5.89

Pdc Tj = 35°C

6.50 kW

7.10 kW

EER Tj = 35°C

3.02

4.88

Pdc Tj = 30°C

4.97 kW

5.65 kW

EER Tj = 30°C

4.12

6.81

Pdc Tj = 25°C

3.35 kW

3.18 kW

EER Tj = 25°C

4.74

5.26

Pdc Tj = 20°C

1.55 kW

1.67 kW

EER Tj = 20°C

5.50

7.40

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Annual energy consumption Qce

881 kWh

723 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

131 %

Prated

7.00 kW

7.00 kW

SCOP

4.50

3.34

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.19 kW

6.19 kW

COP Tj = -7°C

2.97

2.09

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.12 kW

3.79 kW

COP Tj = +2°C

4.46

3.24

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.78 kW

2.49 kW

COP Tj = +7°C

5.70

4.57

Cdh Tj = +7 °C

0.970

0.970

Pdh Tj = 12°C

2.67 kW

2.55 kW

COP Tj = 12°C

7.80

6.10

Cdh Tj = +12 °C

0.960

0.960

Pdh Tj = Tbiv

6.19 kW

6.19 kW

COP Tj = Tbiv

2.97

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.64 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.58

1.66

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.36 kW

2.10 kW

Annual energy consumption Qhe

3213 kWh

4334 kWh