Certificate holders

Subtype

Vitocal 25x-A z5

Certificate Holder
Viessmann Climate Solutions SE
Viessmannstr. 1
35107 Allendorf/Eder
Germany
Registration number
011-1W0776
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Vitocal 25x-A z5
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

2,000 kg

Certification Date
11.03.2024
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 20

Models

Vitocal 250-A AWO-E-AC 251.A16
Configure model
Model name
Vitocal 250-A AWO-E-AC 251.A16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Vitocal 250-A AWO-E-AC 251.A19
Configure model
Model name
Vitocal 250-A AWO-E-AC 251.A19
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh

Vitocal 250-A AWO-E-AC 251.A16 2C
Configure model
Model name
Vitocal 250-A AWO-E-AC 251.A16 2C
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Vitocal 250-A AWO-E-AC 251.A19 2C
Configure model
Model name
Vitocal 250-A AWO-E-AC 251.A19 2C
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh

Vitocal 250-A AWO-E-AC-AF 251.A16
Configure model
Model name
Vitocal 250-A AWO-E-AC-AF 251.A16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Vitocal 250-A AWO-E-AC-AF 251.A19
Configure model
Model name
Vitocal 250-A AWO-E-AC-AF 251.A19
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh

Vitocal 250-A AWO-E-AC-AF 251.A16 2C
Configure model
Model name
Vitocal 250-A AWO-E-AC-AF 251.A16 2C
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Vitocal 250-A AWO-E-AC-AF 251.A19 2C
Configure model
Model name
Vitocal 250-A AWO-E-AC-AF 251.A19 2C
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh

Vitocal 252-A AWOT-E-AC 251.A16
Configure model
Model name
Vitocal 252-A AWOT-E-AC 251.A16
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.2

Heating up time

01:12 h:min

Standby power input

52 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

260 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.44

Heating up time

01:16 h:min

Standby power input

83 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

116 %

COP

2.89

Heating up time

01:14 h:min

Standby power input

55.5 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

260 l

Vitocal 252-A AWOT-E-AC 251.A19
Configure model
Model name
Vitocal 252-A AWOT-E-AC 251.A19
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.2

Heating up time

01:12 h:min

Standby power input

52 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

260 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.44

Heating up time

01:16 h:min

Standby power input

83 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

116 %

COP

2.89

Heating up time

01:14 h:min

Standby power input

55.5 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

260 l

Vitocal 252-A AWOT-E-AC 251.A16 2C
Configure model
Model name
Vitocal 252-A AWOT-E-AC 251.A16 2C
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.2

Heating up time

01:12 h:min

Standby power input

52 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

260 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.44

Heating up time

01:16 h:min

Standby power input

83 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

116 %

COP

2.89

Heating up time

01:14 h:min

Standby power input

55.5 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

260 l

Vitocal 252-A AWOT-E-AC 251.A19 2C
Configure model
Model name
Vitocal 252-A AWOT-E-AC 251.A19 2C
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.2

Heating up time

01:12 h:min

Standby power input

52 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

260 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.44

Heating up time

01:16 h:min

Standby power input

83 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

116 %

COP

2.89

Heating up time

01:14 h:min

Standby power input

55.5 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

260 l

Vitocal 252-A AWOT-E-AC-AF 251.A16
Configure model
Model name
Vitocal 252-A AWOT-E-AC-AF 251.A16
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.2

Heating up time

01:12 h:min

Standby power input

52 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

260 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.44

Heating up time

01:16 h:min

Standby power input

83 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

116 %

COP

2.89

Heating up time

01:14 h:min

Standby power input

55.5 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

260 l

Vitocal 252-A AWOT-E-AC-AF 251.A19
Configure model
Model name
Vitocal 252-A AWOT-E-AC-AF 251.A19
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.2

Heating up time

01:12 h:min

Standby power input

52 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

260 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.44

Heating up time

01:16 h:min

Standby power input

83 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

116 %

COP

2.89

Heating up time

01:14 h:min

Standby power input

55.5 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

260 l

Vitocal 252-A AWOT-E-AC-AF 251.A16 2C
Configure model
Model name
Vitocal 252-A AWOT-E-AC-AF 251.A16 2C
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.2

Heating up time

01:12 h:min

Standby power input

52 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

260 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.44

Heating up time

01:16 h:min

Standby power input

83 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

116 %

COP

2.89

Heating up time

01:14 h:min

Standby power input

55.5 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

260 l

Vitocal 252-A AWOT-E-AC-AF 251.A19 2C
Configure model
Model name
Vitocal 252-A AWOT-E-AC-AF 251.A19 2C
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.2

Heating up time

01:12 h:min

Standby power input

52 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

260 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

98 %

COP

2.44

Heating up time

01:16 h:min

Standby power input

83 W

Reference hot water temperature

53.6 °C

Mixed water at 40°C

260 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

116 %

COP

2.89

Heating up time

01:14 h:min

Standby power input

55.5 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

260 l

Vitocal 250-AH HAWO-AC 252.A16
Configure model
Model name
Vitocal 250-AH HAWO-AC 252.A16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Vitocal 250-AH HAWO-AC 252.A19
Configure model
Model name
Vitocal 250-AH HAWO-AC 252.A19
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh

Vitocal 250-AH HAWO-AC-AF 252.A16
Configure model
Model name
Vitocal 250-AH HAWO-AC-AF 252.A16
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.14 kW

El input

1.60 kW

2.46 kW

COP

5.31

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.24 kW

6.77 kW

ηs

215 %

159 %

Prated

7.24 kW

6.77 kW

SCOP

5.46

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

4.50

2.90

Cdh Tj = +2 °C

0.950

0.970

Pdh Tj = +7°C

7.40 kW

7.00 kW

COP Tj = +7°C

5.70

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.10

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.80 kW

COP Tj = Tbiv

4.50

2.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.50

2.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1772 kWh

2236 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

17.13 kW

16.89 kW

ηs

153 %

127 %

Prated

17.13 kW

16.89 kW

SCOP

3.90

3.26

Tbiv

-9 °C

-9 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

10.30 kW

10.20 kW

COP Tj = -7°C

3.30

2.70

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

6.50 kW

6.30 kW

COP Tj = +2°C

5.50

4.40

Cdh Tj = +2 °C

0.930

0.940

Pdh Tj = +7°C

7.50 kW

7.40 kW

COP Tj = +7°C

6.50

5.40

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.60 kW

8.60 kW

COP Tj = 12°C

7.50

6.40

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.30 kW

11.10 kW

COP Tj = Tbiv

2.90

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

17.13 kW

16.89 kW

Annual energy consumption Qhe

10819 kWh

12788 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.29 kW

12.09 kW

ηs

190 %

153 %

Prated

13.29 kW

12.09 kW

SCOP

4.85

3.92

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.50 kW

10.90 kW

COP Tj = -7°C

2.80

2.30

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.10 kW

6.40 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.40 kW

7.20 kW

COP Tj = +7°C

6.20

5.00

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.60 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

11.50 kW

11.40 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.60 kW

10.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.74 kW

1.25 kW

Annual energy consumption Qhe

5673 kWh

6594 kWh

Vitocal 250-AH HAWO-AC-AF 252.A19
Configure model
Model name
Vitocal 250-AH HAWO-AC-AF 252.A19
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

8.55 kW

El input

1.71 kW

2.59 kW

COP

5.27

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

7.22 kW

6.73 kW

ηs

215 %

159 %

Prated

7.22 kW

6.73 kW

SCOP

5.44

4.05

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.20 kW

6.70 kW

COP Tj = +2°C

4.40

2.80

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

7.30 kW

6.90 kW

COP Tj = +7°C

5.60

3.80

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

8.60 kW

8.40 kW

COP Tj = 12°C

7.20

5.60

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

7.20 kW

6.70 kW

COP Tj = Tbiv

4.40

2.80

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.20 kW

6.70 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.950

0.950

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1773 kWh

2224 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

18.67 kW

18.53 kW

ηs

147 %

121 %

Prated

18.67 kW

18.53 kW

SCOP

3.75

3.10

Tbiv

-8 °C

-8 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

11.20 kW

11.10 kW

COP Tj = -7°C

3.20

2.60

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

6.90 kW

6.60 kW

COP Tj = +2°C

5.40

4.40

Cdh Tj = +2 °C

0.940

0.950

Pdh Tj = +7°C

7.50 kW

7.30 kW

COP Tj = +7°C

6.50

5.50

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

8.50 kW

8.60 kW

COP Tj = 12°C

7.40

6.50

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

11.80 kW

11.70 kW

COP Tj = Tbiv

3.00

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.60 kW

7.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.970

0.980

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

18.67 kW

18.53 kW

Annual energy consumption Qhe

12265 kWh

14724 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

48 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

13.61 kW

13.18 kW

ηs

191 %

152 %

Prated

13.61 kW

13.18 kW

SCOP

4.86

3.89

Tbiv

-7 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.00 kW

11.90 kW

COP Tj = -7°C

2.80

2.20

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.20 kW

6.80 kW

COP Tj = +2°C

5.00

3.90

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

7.50 kW

7.20 kW

COP Tj = +7°C

6.30

5.10

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

8.70 kW

8.50 kW

COP Tj = 12°C

7.70

6.40

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

12.00 kW

12.10 kW

COP Tj = Tbiv

2.80

2.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.00 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

2.00

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

70 °C

70 °C

Poff

11 W

11 W

PTO

16 W

16 W

PSB

16 W

16 W

PCK

33 W

33 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

2.57 kW

1.72 kW

Annual energy consumption Qhe

5897 kWh

7019 kWh