AEROTOP SPK10

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0773
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AEROTOP SPK10
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

3,400 kg

Certification Date
07.02.2024
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 1

Models

AEROTOP SPK10
Configure model
Model name
AEROTOP SPK10
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.10 kW

3.99 kW

El input

0.75 kW

1.29 kW

COP

5.54

3.09

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

272 %

185 %

Prated

8.57 kW

8.64 kW

SCOP

6.88

4.71

Tbiv

2 °C

2 °C

TOL

-22 °C

-22 °C

Pdh Tj = +2°C

8.57 kW

8.64 kW

COP Tj = +2°C

3.51

2.40

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.99 kW

5.93 kW

COP Tj = +7°C

6.41

4.14

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.14 kW

3.82 kW

COP Tj = 12°C

8.36

5.99

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

8.57 kW

8.64 kW

COP Tj = Tbiv

3.51

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.57 kW

8.64 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.51

2.40

WTOL

35 °C

55 °C

Poff

13 W

13 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1665 kWh

2451 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

177 %

135 %

Prated

8.78 kW

8.17 kW

SCOP

4.50

3.44

Tbiv

-17 °C

-17 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.32 kW

5.44 kW

COP Tj = -7°C

4.00

2.84

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.36 kW

3.30 kW

COP Tj = +2°C

5.10

4.25

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.73 kW

3.61 kW

COP Tj = +7°C

7.24

5.52

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

4.03 kW

3.90 kW

COP Tj = 12°C

7.70

6.57

Cdh Tj = +12 °C

0.97

0.97

Pdh Tj = Tbiv

7.62 kW

7.09 kW

COP Tj = Tbiv

2.47

1.70

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.70 kW

5.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.35

WTOL

35 °C

55 °C

Poff

13 W

13 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.08 kW

2.22 kW

Annual energy consumption Qhe

4812 kWh

5852 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.10

7.28

COP Tj = -15°C (if TOL<-20°C)

2.77

1.99

Cdh Tj = -15 °C

0.90

0.90

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

141 %

Prated

7.58 kW

7.40 kW

SCOP

4.86

3.60

Tbiv

-10 °C

-10 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.25 kW

7.03 kW

COP Tj = -7°C

2.92

2.09

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

4.33 kW

4.28 kW

COP Tj = +2°C

4.69

3.45

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.72 kW

3.54 kW

COP Tj = +7°C

6.89

5.07

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.75 kW

4.09 kW

COP Tj = 12°C

7.43

6.60

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

7.58 kW

7.40 kW

COP Tj = Tbiv

2.52

1.75

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.58 kW

7.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.75

WTOL

35 °C

55 °C

Poff

13 W

13 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3225 kWh

4255 kWh