3,100 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.50 kW
4.45 kW
El input
0.82 kW
1.39 kW
COP
5.47
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
249 %
179 %
Prated
5.70 kW
5.89 kW
SCOP
6.30
4.54
Tbiv
2 °C
2 °C
TOL
-22 °C
-22 °C
Pdh Tj = +2°C
5.70 kW
5.89 kW
COP Tj = +2°C
3.85
2.43
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
3.84 kW
4.02 kW
COP Tj = +7°C
6.16
3.98
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
2.32 kW
2.29 kW
COP Tj = 12°C
7.17
5.77
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
5.70 kW
5.89 kW
COP Tj = Tbiv
3.85
2.43
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.70 kW
5.89 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.85
2.43
WTOL
35 °C
55 °C
Poff
13 W
13 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1208 kWh
4215 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
174 %
127 %
Prated
6.16 kW
5.57 kW
SCOP
4.43
3.26
Tbiv
-17 °C
-17 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.71 kW
3.70 kW
COP Tj = -7°C
3.85
2.69
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
2.25 kW
2.25 kW
COP Tj = +2°C
5.28
3.95
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.33 kW
2.29 kW
COP Tj = +7°C
6.52
5.27
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.27 kW
2.41 kW
COP Tj = 12°C
6.83
6.27
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
5.35 kW
4.84 kW
COP Tj = Tbiv
2.45
1.63
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.55 kW
4.09 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.28
WTOL
35 °C
55 °C
Poff
13 W
13 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.61 kW
1.48 kW
Annual energy consumption Qhe
3428 kWh
4215 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.78
4.99
COP Tj = -15°C (if TOL<-20°C)
2.74
1.99
Cdh Tj = -15 °C
0.90
0.90
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
194 %
148 %
Prated
5.59 kW
5.93 kW
SCOP
4.92
3.77
Tbiv
-10 °C
-10 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.29 kW
5.62 kW
COP Tj = -7°C
2.95
2.22
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
3.20 kW
3.46 kW
COP Tj = +2°C
5.08
3.68
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
2.29 kW
2.25 kW
COP Tj = +7°C
6.27
5.11
Cdh Tj = +7 °C
0.96
0.90
Pdh Tj = 12°C
2.33 kW
2.60 kW
COP Tj = 12°C
6.85
6.43
Cdh Tj = +12 °C
0.96
0.96
Pdh Tj = Tbiv
5.59 kW
5.93 kW
COP Tj = Tbiv
2.55
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.59 kW
5.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.55
1.86
WTOL
35 °C
55 °C
Poff
13 W
13 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2346 kWh
3249 kWh