3,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
34.47 kW
25.76 kW
El input
8.64 kW
13.18 kW
COP
4.22
1.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
74 dB(A)
75 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
178 %
128 %
Prated
25.56 kW
25.53 kW
SCOP
4.52
3.26
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
22.61 kW
22.58 kW
COP Tj = -7°C
3.01
2.07
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
14.55 kW
13.83 kW
COP Tj = +2°C
4.47
3.21
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
15.36 kW
12.37 kW
COP Tj = +7°C
6.18
4.32
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
18.33 kW
13.96 kW
COP Tj = 12°C
8.25
6.15
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
22.61 kW
22.58 kW
COP Tj = Tbiv
3.01
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
24.74 kW
25.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
70 °C
70 °C
Poff
20 W
20 W
PTO
20 W
20 W
PSB
20 W
20 W
PCK
120 W
120 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.82 kW
0.00 kW
Annual energy consumption Qhe
11670 kWh
16158 kWh