1,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.98 kW
17.09 kW
El input
4.02 kW
5.90 kW
COP
4.22
2.90
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
62 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
141 %
Prated
16.66 kW
17.07 kW
SCOP
4.65
3.61
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
14.74 kW
15.10 kW
COP Tj = -7°C
2.76
2.15
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.98 kW
9.37 kW
COP Tj = +2°C
4.52
3.49
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.82 kW
6.02 kW
COP Tj = +7°C
6.43
4.98
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.06 kW
5.80 kW
COP Tj = 12°C
8.11
6.41
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
14.74 kW
15.10 kW
COP Tj = Tbiv
2.76
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.05 kW
15.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.48
1.93
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
12 W
12 W
PSB
11 W
11 W
PCK
86 W
86 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
2.03 kW
Annual energy consumption Qhe
7404 kWh
9777 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
17.02 kW
16.92 kW
El input
4.03 kW
5.57 kW
COP
4.23
3.04
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
142 %
Prated
16.71 kW
16.62 kW
SCOP
4.64
3.62
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
14.78 kW
14.70 kW
COP Tj = -7°C
2.85
2.15
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
9.16 kW
9.09 kW
COP Tj = +2°C
4.49
3.54
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.80 kW
5.76 kW
COP Tj = +7°C
6.27
4.87
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.04 kW
5.86 kW
COP Tj = 12°C
8.36
6.91
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
14.78 kW
14.70 kW
COP Tj = Tbiv
2.85
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.57 kW
14.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
88 W
88 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.14 kW
2.57 kW
Annual energy consumption Qhe
7440 kWh
9486 kWh