Certificate holders

Subtype

DE DIETRICH MHTC R290 020

Certificate Holder
BDR Thermea FR (DE DIETRICH)
57 rue de la Gare
67580 Mertzwiller
France
Registration number
007-DO0170
Certification Body
Kiwa Nederland B.V.
Subtype title
DE DIETRICH MHTC R290 020
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

4,450 kg

Certification Date
21.02.2024
Testing basis
European KEYMARK Scheme for Heat Pumps (v12)
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

MHTC R290 020
Configure model
Model name
MHTC R290 020
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.00 kW

20.00 kW

El input

4.36 kW

6.67 kW

COP

4.60

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

6.06 kW

3.89 kW

Cooling capacity

20.00

20.00

EER

3.31

5.14

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

20.00 kW

20.00 kW

SEER

5.29

5.29

Pdc Tj = 35°C

20.00 kW

20.00 kW

EER Tj = 35°C

3.31

5.14

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

14.74 kW

14.74 kW

EER Tj = 30°C

4.73

6.52

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

9.47 kW

9.71 kW

EER Tj = 25°C

6.63

6.80

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

6.76 kW

7.50 kW

EER Tj = 20°C

8.14

7.10

Cdc Tj = 20 °C

0.900

0.900

Poff

0 W

0 W

PTO

166 W

200 W

PSB

166 W

166 W

PCK

0 W

0 W

Annual energy consumption Qce

2270 kWh

2201 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

151 %

Prated

20.00 kW

20.00 kW

SCOP

5.00

3.86

Tbiv

-10 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

17.52 kW

17.69 kW

COP Tj = -7°C

2.90

2.24

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.78 kW

10.77 kW

COP Tj = +2°C

5.04

3.85

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.84 kW

6.92 kW

COP Tj = +7°C

6.59

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.37 kW

7.18 kW

COP Tj = 12°C

8.50

7.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

20.00 kW

17.69 kW

COP Tj = Tbiv

2.49

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.00 kW

16.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.49

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

162 W

19 W

PTO

162 W

122 W

PSB

162 W

19 W

PCK

0 W

158 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

3.62 kW

Annual energy consumption Qhe

8265 kWh

10718 kWh

MHTC R290 020 HR
Configure model
Model name
MHTC R290 020 HR
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.00 kW

20.00 kW

El input

4.36 kW

6.67 kW

COP

4.60

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

6.06 kW

3.89 kW

Cooling capacity

20.00

20.00

EER

3.31

5.14

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

20.00 kW

20.00 kW

SEER

5.29

5.29

Pdc Tj = 35°C

20.00 kW

20.00 kW

EER Tj = 35°C

3.31

5.14

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

14.74 kW

14.74 kW

EER Tj = 30°C

4.73

6.52

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

9.47 kW

9.71 kW

EER Tj = 25°C

6.63

6.80

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

6.76 kW

7.50 kW

EER Tj = 20°C

8.14

7.10

Cdc Tj = 20 °C

0.900

0.900

Poff

0 W

0 W

PTO

166 W

200 W

PSB

166 W

166 W

PCK

0 W

0 W

Annual energy consumption Qce

2270 kWh

2201 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

151 %

Prated

20.00 kW

20.00 kW

SCOP

5.00

3.86

Tbiv

-10 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

17.52 kW

17.69 kW

COP Tj = -7°C

2.90

2.24

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

10.78 kW

10.77 kW

COP Tj = +2°C

5.04

3.85

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.84 kW

6.92 kW

COP Tj = +7°C

6.59

5.26

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.37 kW

7.18 kW

COP Tj = 12°C

8.50

7.10

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

20.00 kW

17.69 kW

COP Tj = Tbiv

2.49

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

20.00 kW

16.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.49

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

162 W

19 W

PTO

162 W

122 W

PSB

162 W

19 W

PCK

0 W

158 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

3.62 kW

Annual energy consumption Qhe

8265 kWh

10718 kWh