Certificate holders

Subtype

DE DIETRICH MHTC R290 030

Certificate Holder
BDR Thermea FR (DE DIETRICH)
57 rue de la Gare
67580 Mertzwiller
France
Registration number
007-DO0176
Certification Body
Kiwa Nederland B.V.
Subtype title
DE DIETRICH MHTC R290 030
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

4,750 kg

Certification Date
21.02.2024
Testing basis
European KEYMARK Scheme for Heat Pumps (v12)
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

MHTC R290 030
Configure model
Model name
MHTC R290 030
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

30.00 kW

30.00 kW

El input

6.52 kW

10.07 kW

COP

4.60

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

7.56 kW

6.98 kW

Cooling capacity

23.30

30.00

EER

3.08

4.30

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

23.30 kW

30.00 kW

SEER

4.55

5.31

Pdc Tj = 35°C

23.30 kW

30.00 kW

EER Tj = 35°C

3.08

4.30

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

17.68 kW

22.11 kW

EER Tj = 30°C

4.15

5.17

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

11.37 kW

14.21 kW

EER Tj = 25°C

5.62

6.63

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

5.78 kW

7.90 kW

EER Tj = 20°C

5.80

7.20

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

300 W

PTO

166 W

166 W

PSB

0 W

0 W

PCK

0 W

0 W

Annual energy consumption Qce

3075 kWh

3390 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

155 %

Prated

30.00 kW

30.00 kW

SCOP

5.17

3.96

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

26.41 kW

26.54 kW

COP Tj = -7°C

2.97

2.17

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

16.15 kW

16.25 kW

COP Tj = +2°C

5.21

3.93

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.38 kW

10.39 kW

COP Tj = +7°C

7.15

5.45

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

8.17 kW

8.30 kW

COP Tj = 12°C

8.01

7.65

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

26.41 kW

26.54 kW

COP Tj = Tbiv

2.97

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25.31 kW

25.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

135 W

135 W

PTO

200 W

175 W

PSB

135 W

135 W

PCK

90 W

90 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.69 kW

4.93 kW

Annual energy consumption Qhe

3390 kWh

3149 kWh

MHTC R290 030 HR
Configure model
Model name
MHTC R290 030 HR
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

30.00 kW

30.00 kW

El input

6.52 kW

10.07 kW

COP

4.60

2.98

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

7.56 kW

6.98 kW

Cooling capacity

23.30

30.00

EER

3.08

4.30

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

23.30 kW

30.00 kW

SEER

4.55

5.31

Pdc Tj = 35°C

23.30 kW

30.00 kW

EER Tj = 35°C

3.08

4.30

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

17.68 kW

22.11 kW

EER Tj = 30°C

4.15

5.17

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

11.37 kW

14.21 kW

EER Tj = 25°C

5.62

6.63

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

5.78 kW

7.90 kW

EER Tj = 20°C

5.80

7.20

Cdc Tj = 20 °C

0.900

0.900

Poff

20 W

300 W

PTO

166 W

166 W

PSB

0 W

0 W

PCK

0 W

0 W

Annual energy consumption Qce

3075 kWh

3390 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

155 %

Prated

30.00 kW

30.00 kW

SCOP

5.17

3.96

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

26.41 kW

26.54 kW

COP Tj = -7°C

2.97

2.17

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

16.15 kW

16.25 kW

COP Tj = +2°C

5.21

3.93

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.38 kW

10.39 kW

COP Tj = +7°C

7.15

5.45

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

8.17 kW

8.30 kW

COP Tj = 12°C

8.01

7.65

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

26.41 kW

26.54 kW

COP Tj = Tbiv

2.97

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

25.31 kW

25.07 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

35 °C

55 °C

Poff

135 W

135 W

PTO

200 W

175 W

PSB

135 W

135 W

PCK

90 W

90 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.69 kW

4.93 kW

Annual energy consumption Qhe

3390 kWh

3149 kWh