0,980 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.98 kW
9.25 kW
El input
2.13 kW
3.00 kW
COP
4.67
3.09
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
143 %
Prated
9.84 kW
9.80 kW
SCOP
4.85
3.65
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
8.70 kW
8.67 kW
COP Tj = -7°C
3.17
2.39
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.31 kW
5.28 kW
COP Tj = +2°C
4.82
3.61
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
3.68 kW
3.66 kW
COP Tj = +7°C
5.98
4.60
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.18 kW
3.91 kW
COP Tj = 12°C
8.38
5.89
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.70 kW
8.67 kW
COP Tj = Tbiv
3.17
2.39
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.75 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.11
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
11 W
11 W
PTO
12 W
12 W
PSB
11 W
11 W
PCK
44 W
44 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.09 kW
0.49 kW
Annual energy consumption Qhe
4187 kWh
5554 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.92 kW
9.25 kW
El input
2.21 kW
3.02 kW
COP
4.50
3.06
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
61 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
138 %
Prated
9.83 kW
9.83 kW
SCOP
4.80
3.53
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
8.70 kW
8.69 kW
COP Tj = -7°C
3.18
2.35
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.30 kW
5.31 kW
COP Tj = +2°C
4.70
3.45
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.53 kW
4.29 kW
COP Tj = +7°C
6.22
4.61
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.16 kW
4.99 kW
COP Tj = 12°C
8.34
6.19
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.70 kW
8.69 kW
COP Tj = Tbiv
3.18
2.35
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.70 kW
9.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
11 W
11 W
PSB
10 W
10 W
PCK
48 W
48 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.13 kW
0.64 kW
Annual energy consumption Qhe
4232 kWh
5748 kWh