Certificate holders

Subtype

Vitocal 2xx-G B17

Certificate Holder
Viessmann Climate Solutions SE
Viessmannstr. 1
35107 Allendorf/Eder
Germany
Registration number
011-1W0211
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Vitocal 2xx-G B17
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

2,350 kg

Certification Date
18.08.2020
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

VITOCAL 200-G BWC 201.B17
Configure model
Model name
VITOCAL 200-G BWC 201.B17
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

17.33 kW

16.02 kW

El input

3.94 kW

5.57 kW

COP

4.40

2.88

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

137 %

Prated

17.35 kW

16.12 kW

SCOP

4.81

3.63

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

17.33 kW

16.02 kW

COP Tj = +2°C

4.40

2.88

Cdh Tj = +2 °C

0.998

0.999

Pdh Tj = +7°C

17.49 kW

16.39 kW

COP Tj = +7°C

4.66

3.31

Cdh Tj = +7 °C

0.998

0.999

Pdh Tj = 12°C

17.71 kW

16.97 kW

COP Tj = 12°C

5.04

4.07

Cdh Tj = +12 °C

0.998

0.998

Pdh Tj = Tbiv

17.33 kW

16.02 kW

COP Tj = Tbiv

4.40

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.33 kW

16.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.998

0.999

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4817 kWh

5940 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

17.35 kW

16.15 kW

SCOP

4.85

3.67

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

17.52 kW

16.49 kW

COP Tj = -7°C

4.76

3.43

Cdh Tj = -7 °C

0.998

0.998

Pdh Tj = +2°C

17.59 kW

16.80 kW

COP Tj = +2°C

4.95

3.85

Cdh Tj = +2 °C

0.998

0.998

Pdh Tj = +7°C

17.71 kW

17.05 kW

COP Tj = +7°C

5.11

4.22

Cdh Tj = +7 °C

0.998

0.998

Pdh Tj = 12°C

17.73 kW

17.28 kW

COP Tj = 12°C

5.17

4.54

Cdh Tj = +12 °C

0.998

0.998

Pdh Tj = Tbiv

17.33 kW

16.02 kW

COP Tj = Tbiv

4.40

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.33 kW

16.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.998

0.999

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

8813 kWh

10843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

141 %

Prated

17.31 kW

16.13 kW

SCOP

4.75

3.73

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.41 kW

16.13 kW

COP Tj = -7°C

4.47

3.13

Cdh Tj = -7 °C

0.998

0.999

Pdh Tj = +2°C

17.48 kW

16.61 kW

COP Tj = +2°C

4.70

3.68

Cdh Tj = +2 °C

0.998

0.998

Pdh Tj = +7°C

17.63 kW

16.88 kW

COP Tj = +7°C

4.00

4.07

Cdh Tj = +7 °C

0.998

0.998

Pdh Tj = 12°C

17.75 kW

17.17 kW

COP Tj = 12°C

4.94

4.50

Cdh Tj = +12 °C

0.998

0.998

Pdh Tj = Tbiv

17.33 kW

16.02 kW

COP Tj = Tbiv

4.40

2.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.33 kW

16.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.998

0.999

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

7531 kWh

8944 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

22.67 kW

20.32 kW

El input

4.46 kW

6.05 kW

COP

5.08

3.36

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

210 %

165 %

Prated

22.60 kW

20.30 kW

SCOP

5.45

4.33

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

22.67 kW

20.32 kW

COP Tj = +2°C

5.08

3.36

Cdh Tj = +2 °C

0.996

0.998

Pdh Tj = +7°C

22.76 kW

21.08 kW

COP Tj = +7°C

5.31

3.92

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

23.10 kW

22.15 kW

COP Tj = 12°C

5.71

4.96

Cdh Tj = +12 °C

0.996

0.997

Pdh Tj = Tbiv

22.67 kW

20.32 kW

COP Tj = Tbiv

5.08

3.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.67 kW

20.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.08

3.36

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5538 kWh

6258 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

192 %

161 %

Prated

37.80 kW

35.50 kW

SCOP

5.00

4.23

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

23.10 kW

21.70 kW

COP Tj = -7°C

5.68

4.51

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

23.21 kW

22.10 kW

COP Tj = +2°C

5.81

4.94

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

23.30 kW

22.43 kW

COP Tj = +7°C

5.92

5.34

Cdh Tj = +7 °C

0.996

0.996

Pdh Tj = 12°C

23.33 kW

22.61 kW

COP Tj = 12°C

5.92

5.62

Cdh Tj = +12 °C

0.996

0.996

Pdh Tj = Tbiv

23.10 kW

21.70 kW

COP Tj = Tbiv

5.68

4.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.67 kW

20.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.08

3.36

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

15.13 kW

15.18 kW

Annual energy consumption Qhe

18645 kWh

20708 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

210 %

166 %

Prated

25.80 kW

23.50 kW

SCOP

5.45

4.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

22.78 kW

20.73 kW

COP Tj = -7°C

5.20

3.65

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

22.95 kW

21.48 kW

COP Tj = +2°C

5.45

4.33

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

23.14 kW

21.98 kW

COP Tj = +7°C

5.69

4.82

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

23.29 kW

22.41 kW

COP Tj = 12°C

5.90

5.34

Cdh Tj = +12 °C

0.996

0.996

Pdh Tj = Tbiv

22.73 kW

20.73 kW

COP Tj = Tbiv

5.20

3.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.67 kW

20.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.08

3.36

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.13 kW

3.18 kW

Annual energy consumption Qhe

9789 kWh

11140 kWh

VITOCAL 200-G BWC 201.B17 SC
Configure model
Model name
VITOCAL 200-G BWC 201.B17 SC
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

17.33 kW

16.02 kW

El input

3.94 kW

5.57 kW

COP

4.40

2.88

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

137 %

Prated

17.35 kW

16.12 kW

SCOP

4.81

3.63

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

17.33 kW

16.02 kW

COP Tj = +2°C

4.40

2.88

Cdh Tj = +2 °C

0.998

0.999

Pdh Tj = +7°C

17.49 kW

16.39 kW

COP Tj = +7°C

4.66

3.31

Cdh Tj = +7 °C

0.998

0.999

Pdh Tj = 12°C

17.71 kW

16.97 kW

COP Tj = 12°C

5.04

4.07

Cdh Tj = +12 °C

0.998

0.998

Pdh Tj = Tbiv

17.33 kW

16.02 kW

COP Tj = Tbiv

4.40

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.33 kW

16.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.998

0.999

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4817 kWh

5940 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

139 %

Prated

17.35 kW

16.15 kW

SCOP

4.85

3.67

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

17.52 kW

16.49 kW

COP Tj = -7°C

4.76

3.43

Cdh Tj = -7 °C

0.998

0.998

Pdh Tj = +2°C

17.59 kW

16.80 kW

COP Tj = +2°C

4.95

3.85

Cdh Tj = +2 °C

0.998

0.998

Pdh Tj = +7°C

17.71 kW

17.05 kW

COP Tj = +7°C

5.11

4.22

Cdh Tj = +7 °C

0.998

0.998

Pdh Tj = 12°C

17.73 kW

17.28 kW

COP Tj = 12°C

5.17

4.54

Cdh Tj = +12 °C

0.998

0.998

Pdh Tj = Tbiv

17.33 kW

16.02 kW

COP Tj = Tbiv

4.40

2.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.33 kW

16.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.998

0.999

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

8813 kWh

10843 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

141 %

Prated

17.31 kW

16.13 kW

SCOP

4.75

3.73

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.41 kW

16.13 kW

COP Tj = -7°C

4.47

3.13

Cdh Tj = -7 °C

0.998

0.999

Pdh Tj = +2°C

17.48 kW

16.61 kW

COP Tj = +2°C

4.70

3.68

Cdh Tj = +2 °C

0.998

0.998

Pdh Tj = +7°C

17.63 kW

16.88 kW

COP Tj = +7°C

4.00

4.07

Cdh Tj = +7 °C

0.998

0.998

Pdh Tj = 12°C

17.75 kW

17.17 kW

COP Tj = 12°C

4.94

4.50

Cdh Tj = +12 °C

0.998

0.998

Pdh Tj = Tbiv

17.33 kW

16.02 kW

COP Tj = Tbiv

4.40

2.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.33 kW

16.02 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.40

2.97

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.998

0.999

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

7 W

7 W

PSB

7 W

7 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

7531 kWh

8944 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

22.67 kW

20.32 kW

El input

4.46 kW

6.05 kW

COP

5.08

3.36

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

210 %

165 %

Prated

22.60 kW

20.30 kW

SCOP

5.45

4.33

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

22.67 kW

20.32 kW

COP Tj = +2°C

5.08

3.36

Cdh Tj = +2 °C

0.996

0.998

Pdh Tj = +7°C

22.76 kW

21.08 kW

COP Tj = +7°C

5.31

3.92

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

23.10 kW

22.15 kW

COP Tj = 12°C

5.71

4.96

Cdh Tj = +12 °C

0.996

0.997

Pdh Tj = Tbiv

22.67 kW

20.32 kW

COP Tj = Tbiv

5.08

3.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.67 kW

20.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.08

3.36

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5538 kWh

6258 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

192 %

161 %

Prated

37.80 kW

35.50 kW

SCOP

5.00

4.23

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

23.10 kW

21.70 kW

COP Tj = -7°C

5.68

4.51

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

23.21 kW

22.10 kW

COP Tj = +2°C

5.81

4.94

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

23.30 kW

22.43 kW

COP Tj = +7°C

5.92

5.34

Cdh Tj = +7 °C

0.996

0.996

Pdh Tj = 12°C

23.33 kW

22.61 kW

COP Tj = 12°C

5.92

5.62

Cdh Tj = +12 °C

0.996

0.996

Pdh Tj = Tbiv

23.10 kW

21.70 kW

COP Tj = Tbiv

5.68

4.51

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.67 kW

20.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.08

3.36

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

15.13 kW

15.18 kW

Annual energy consumption Qhe

18645 kWh

20708 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

210 %

166 %

Prated

25.80 kW

23.50 kW

SCOP

5.45

4.36

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

22.78 kW

20.73 kW

COP Tj = -7°C

5.20

3.65

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

22.95 kW

21.48 kW

COP Tj = +2°C

5.45

4.33

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

23.14 kW

21.98 kW

COP Tj = +7°C

5.69

4.82

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

23.29 kW

22.41 kW

COP Tj = 12°C

5.90

5.34

Cdh Tj = +12 °C

0.996

0.996

Pdh Tj = Tbiv

22.73 kW

20.73 kW

COP Tj = Tbiv

5.20

3.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

22.67 kW

20.32 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.08

3.36

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.13 kW

3.18 kW

Annual energy consumption Qhe

9789 kWh

11140 kWh