Certificate holders

Subtype

Vitocal 2xx-G B13

Certificate Holder
Viessmann Climate Solutions SE
Viessmannstr. 1
35107 Allendorf/Eder
Germany
Registration number
011-1W0210
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Vitocal 2xx-G B13
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

1,950 kg

Certification Date
06.10.2020
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

Vitocal 200-G BWC 201.B13
Configure model
Model name
Vitocal 200-G BWC 201.B13
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.27 kW

12.11 kW

El input

2.89 kW

4.11 kW

COP

4.56

2.95

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

141 %

Prated

13.19 kW

12.17 kW

SCOP

5.01

3.72

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.22 kW

12.10 kW

COP Tj = +2°C

4.57

2.94

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

13.35 kW

12.47 kW

COP Tj = +7°C

4.84

3.38

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

13.52 kW

12.96 kW

COP Tj = 12°C

5.27

4.20

Cdh Tj = +12 °C

0.997

0.998

Pdh Tj = Tbiv

13.22 kW

12.10 kW

COP Tj = Tbiv

4.57

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.22 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.57

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3520 kWh

4376 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

143 %

Prated

13.19 kW

12.17 kW

SCOP

5.06

3.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

13.40 kW

12.55 kW

COP Tj = -7°C

4.94

3.52

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

13.50 kW

12.82 kW

COP Tj = +2°C

5.19

3.96

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

13.56 kW

13.05 kW

COP Tj = +7°C

5.36

4.36

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

13.59 kW

13.18 kW

COP Tj = 12°C

5.41

4.67

Cdh Tj = +12 °C

0.997

0.997

Pdh Tj = Tbiv

13.22 kW

12.10 kW

COP Tj = Tbiv

4.57

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.22 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.57

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6426 kWh

7959 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

140 %

Prated

13.19 kW

12.17 kW

SCOP

4.94

3.70

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.24 kW

12.22 kW

COP Tj = -7°C

4.63

3.09

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

13.32 kW

12.63 kW

COP Tj = +2°C

4.88

3.65

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

13.47 kW

12.87 kW

COP Tj = +7°C

5.17

4.06

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

13.58 kW

13.07 kW

COP Tj = 12°C

5.44

4.48

Cdh Tj = +12 °C

0.997

0.997

Pdh Tj = Tbiv

13.20 kW

12.11 kW

COP Tj = Tbiv

4.56

2.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.20 kW

12.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.56

2.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5520 kWh

6797 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

17.74 kW

15.96 kW

El input

3.01 kW

4.28 kW

COP

5.90

3.73

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

249 %

185 %

Prated

17.31 kW

15.67 kW

SCOP

6.41

4.83

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

17.74 kW

15.96 kW

COP Tj = +2°C

5.90

3.73

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

17.90 kW

16.49 kW

COP Tj = +7°C

6.22

4.34

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

18.15 kW

17.29 kW

COP Tj = 12°C

6.73

5.55

Cdh Tj = +12 °C

0.997

0.998

Pdh Tj = Tbiv

17.74 kW

15.96 kW

COP Tj = Tbiv

5.90

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.74 kW

15.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.90

3.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3605 kWh

4331 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

222 %

177 %

Prated

28.50 kW

27.00 kW

SCOP

5.76

4.63

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

18.05 kW

16.89 kW

COP Tj = -7°C

6.65

4.96

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

18.18 kW

17.22 kW

COP Tj = +2°C

6.80

5.47

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

18.28 kW

17.48 kW

COP Tj = +7°C

6.99

5.96

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

18.26 kW

17.65 kW

COP Tj = 12°C

6.98

6.33

Cdh Tj = +12 °C

0.997

0.997

Pdh Tj = Tbiv

18.05 kW

16.89 kW

COP Tj = Tbiv

6.65

4.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.74 kW

15.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.90

3.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.76 kW

11.04 kW

Annual energy consumption Qhe

12206 kWh

14365 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

246 %

185 %

Prated

19.40 kW

18.00 kW

SCOP

6.36

4.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.76 kW

16.28 kW

COP Tj = -7°C

5.99

4.02

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

17.86 kW

16.80 kW

COP Tj = +2°C

6.30

4.78

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

18.13 kW

17.17 kW

COP Tj = +7°C

6.74

5.36

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

18.26 kW

17.48 kW

COP Tj = 12°C

6.99

6.00

Cdh Tj = +12 °C

0.997

0.997

Pdh Tj = Tbiv

17.76 kW

16.28 kW

COP Tj = Tbiv

5.99

4.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.74 kW

15.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.90

3.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.66 kW

2.04 kW

Annual energy consumption Qhe

6302 kWh

7696 kWh

Vitocal 200-G BWC 201.B13 SC
Configure model
Model name
Vitocal 200-G BWC 201.B13 SC
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.27 kW

12.11 kW

El input

2.89 kW

4.11 kW

COP

4.56

2.95

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

141 %

Prated

13.19 kW

12.17 kW

SCOP

5.01

3.72

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.22 kW

12.10 kW

COP Tj = +2°C

4.57

2.94

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

13.35 kW

12.47 kW

COP Tj = +7°C

4.84

3.38

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

13.52 kW

12.96 kW

COP Tj = 12°C

5.27

4.20

Cdh Tj = +12 °C

0.997

0.998

Pdh Tj = Tbiv

13.22 kW

12.10 kW

COP Tj = Tbiv

4.57

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.22 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.57

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3520 kWh

4376 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

194 %

143 %

Prated

13.19 kW

12.17 kW

SCOP

5.06

3.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

13.40 kW

12.55 kW

COP Tj = -7°C

4.94

3.52

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

13.50 kW

12.82 kW

COP Tj = +2°C

5.19

3.96

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

13.56 kW

13.05 kW

COP Tj = +7°C

5.36

4.36

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

13.59 kW

13.18 kW

COP Tj = 12°C

5.41

4.67

Cdh Tj = +12 °C

0.997

0.997

Pdh Tj = Tbiv

13.22 kW

12.10 kW

COP Tj = Tbiv

4.57

2.94

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.22 kW

12.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.57

2.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

6426 kWh

7959 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

46 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

140 %

Prated

13.19 kW

12.17 kW

SCOP

4.94

3.70

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.24 kW

12.22 kW

COP Tj = -7°C

4.63

3.09

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

13.32 kW

12.63 kW

COP Tj = +2°C

4.88

3.65

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

13.47 kW

12.87 kW

COP Tj = +7°C

5.17

4.06

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

13.58 kW

13.07 kW

COP Tj = 12°C

5.44

4.48

Cdh Tj = +12 °C

0.997

0.997

Pdh Tj = Tbiv

13.20 kW

12.11 kW

COP Tj = Tbiv

4.56

2.95

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.20 kW

12.11 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.56

2.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5520 kWh

6797 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

17.74 kW

15.96 kW

El input

3.01 kW

4.28 kW

COP

5.90

3.73

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

249 %

185 %

Prated

17.31 kW

15.67 kW

SCOP

6.41

4.83

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

17.74 kW

15.96 kW

COP Tj = +2°C

5.90

3.73

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

17.90 kW

16.49 kW

COP Tj = +7°C

6.22

4.34

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

18.15 kW

17.29 kW

COP Tj = 12°C

6.73

5.55

Cdh Tj = +12 °C

0.997

0.998

Pdh Tj = Tbiv

17.74 kW

15.96 kW

COP Tj = Tbiv

5.90

3.73

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.74 kW

15.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.90

3.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3605 kWh

4331 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

222 %

177 %

Prated

28.50 kW

27.00 kW

SCOP

5.76

4.63

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

18.05 kW

16.89 kW

COP Tj = -7°C

6.65

4.96

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

18.18 kW

17.22 kW

COP Tj = +2°C

6.80

5.47

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

18.28 kW

17.48 kW

COP Tj = +7°C

6.99

5.96

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

18.26 kW

17.65 kW

COP Tj = 12°C

6.98

6.33

Cdh Tj = +12 °C

0.997

0.997

Pdh Tj = Tbiv

18.05 kW

16.89 kW

COP Tj = Tbiv

6.65

4.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.74 kW

15.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.90

3.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

10.76 kW

11.04 kW

Annual energy consumption Qhe

12206 kWh

14365 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

246 %

185 %

Prated

19.40 kW

18.00 kW

SCOP

6.36

4.83

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

17.76 kW

16.28 kW

COP Tj = -7°C

5.99

4.02

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

17.86 kW

16.80 kW

COP Tj = +2°C

6.30

4.78

Cdh Tj = +2 °C

0.997

0.998

Pdh Tj = +7°C

18.13 kW

17.17 kW

COP Tj = +7°C

6.74

5.36

Cdh Tj = +7 °C

0.997

0.998

Pdh Tj = 12°C

18.26 kW

17.48 kW

COP Tj = 12°C

6.99

6.00

Cdh Tj = +12 °C

0.997

0.997

Pdh Tj = Tbiv

17.76 kW

16.28 kW

COP Tj = Tbiv

5.99

4.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

17.74 kW

15.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.90

3.73

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.66 kW

2.04 kW

Annual energy consumption Qhe

6302 kWh

7696 kWh