1,800 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.27 kW
9.31 kW
El input
2.16 kW
3.15 kW
COP
4.75
2.96
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
143 %
Prated
10.27 kW
9.39 kW
SCOP
5.23
3.77
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.27 kW
9.31 kW
COP Tj = +2°C
4.75
2.96
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
10.35 kW
9.64 kW
COP Tj = +7°C
5.05
3.43
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.52 kW
10.06 kW
COP Tj = 12°C
5.54
4.29
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
10.27 kW
9.31 kW
COP Tj = Tbiv
4.75
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2623 kWh
3323 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
141 %
Prated
17.18 kW
15.83 kW
SCOP
4.86
3.73
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.48 kW
9.86 kW
COP Tj = -7°C
5.48
3.88
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.55 kW
10.04 kW
COP Tj = +2°C
5.64
4.26
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.60 kW
10.17 kW
COP Tj = +7°C
5.79
4.62
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.60 kW
10.25 kW
COP Tj = 12°C
5.78
4.88
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
10.48 kW
9.86 kW
COP Tj = Tbiv
5.48
3.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.91 kW
6.52 kW
Annual energy consumption Qhe
8717 kWh
10461 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
11.72 kW
10.81 kW
SCOP
5.21
3.95
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.32 kW
9.46 kW
COP Tj = -7°C
4.91
3.19
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.41 kW
9.97 kW
COP Tj = +2°C
5.19
4.10
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.51 kW
10.00 kW
COP Tj = +7°C
5.48
4.18
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.57 kW
10.18 kW
COP Tj = 12°C
5.76
4.64
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
10.32 kW
9.46 kW
COP Tj = Tbiv
4.91
3.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.45 kW
1.50 kW
Annual energy consumption Qhe
4651 kWh
5652 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
13.82 kW
12.48 kW
El input
2.22 kW
3.29 kW
COP
6.23
3.79
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
272 %
192 %
Prated
13.40 kW
12.40 kW
SCOP
7.01
5.00
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.82 kW
12.48 kW
COP Tj = +2°C
6.23
3.79
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
14.02 kW
12.93 kW
COP Tj = +7°C
6.77
4.47
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.26 kW
13.60 kW
COP Tj = 12°C
7.44
5.80
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
13.82 kW
12.48 kW
COP Tj = Tbiv
6.23
3.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2556 kWh
3313 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
241 %
184 %
Prated
22.40 kW
21.60 kW
SCOP
6.22
4.81
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
14.24 kW
13.32 kW
COP Tj = -7°C
7.33
5.18
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
14.29 kW
13.58 kW
COP Tj = +2°C
7.53
5.77
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
14.37 kW
13.79 kW
COP Tj = +7°C
7.73
6.31
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.36 kW
13.95 kW
COP Tj = 12°C
7.74
6.71
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
14.24 kW
13.32 kW
COP Tj = Tbiv
7.33
5.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.58 kW
9.12 kW
Annual energy consumption Qhe
8875 kWh
11076 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
269 %
192 %
Prated
15.20 kW
14.20 kW
SCOP
6.93
5.01
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.94 kW
12.74 kW
COP Tj = -7°C
6.53
4.12
Cdh Tj = -7 °C
0.996
0.998
Pdh Tj = +2°C
14.04 kW
13.22 kW
COP Tj = +2°C
6.89
4.96
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
14.23 kW
13.51 kW
COP Tj = +7°C
7.34
5.61
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.36 kW
13.79 kW
COP Tj = 12°C
7.68
6.31
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
13.94 kW
12.74 kW
COP Tj = Tbiv
6.53
4.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
1.72 kW
Annual energy consumption Qhe
4533 kWh
5856 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.27 kW
9.31 kW
El input
2.16 kW
3.15 kW
COP
4.75
2.96
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
143 %
Prated
10.27 kW
9.39 kW
SCOP
5.23
3.77
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.27 kW
9.31 kW
COP Tj = +2°C
4.75
2.96
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
10.35 kW
9.64 kW
COP Tj = +7°C
5.05
3.43
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.52 kW
10.06 kW
COP Tj = 12°C
5.54
4.29
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
10.27 kW
9.31 kW
COP Tj = Tbiv
4.75
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2623 kWh
3323 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
141 %
Prated
17.18 kW
15.83 kW
SCOP
4.86
3.73
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.48 kW
9.86 kW
COP Tj = -7°C
5.48
3.88
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.55 kW
10.04 kW
COP Tj = +2°C
5.64
4.26
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.60 kW
10.17 kW
COP Tj = +7°C
5.79
4.62
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.60 kW
10.25 kW
COP Tj = 12°C
5.78
4.88
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
10.48 kW
9.86 kW
COP Tj = Tbiv
5.48
3.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.91 kW
6.52 kW
Annual energy consumption Qhe
8717 kWh
10461 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
11.72 kW
10.81 kW
SCOP
5.21
3.95
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.32 kW
9.46 kW
COP Tj = -7°C
4.91
3.19
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.41 kW
9.97 kW
COP Tj = +2°C
5.19
4.10
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.51 kW
10.00 kW
COP Tj = +7°C
5.48
4.18
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.57 kW
10.18 kW
COP Tj = 12°C
5.76
4.64
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
10.32 kW
9.46 kW
COP Tj = Tbiv
4.91
3.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.45 kW
1.50 kW
Annual energy consumption Qhe
4651 kWh
5652 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
13.82 kW
12.48 kW
El input
2.22 kW
3.29 kW
COP
6.23
3.79
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
272 %
192 %
Prated
13.40 kW
12.40 kW
SCOP
7.01
5.00
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.82 kW
12.48 kW
COP Tj = +2°C
6.23
3.79
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
14.02 kW
12.93 kW
COP Tj = +7°C
6.77
4.47
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.26 kW
13.60 kW
COP Tj = 12°C
7.44
5.80
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
13.82 kW
12.48 kW
COP Tj = Tbiv
6.23
3.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2556 kWh
3313 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
241 %
184 %
Prated
22.40 kW
21.60 kW
SCOP
6.22
4.81
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
14.24 kW
13.32 kW
COP Tj = -7°C
7.33
5.18
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
14.29 kW
13.58 kW
COP Tj = +2°C
7.53
5.77
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
14.37 kW
13.79 kW
COP Tj = +7°C
7.73
6.31
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.36 kW
13.95 kW
COP Tj = 12°C
7.74
6.71
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
14.24 kW
13.32 kW
COP Tj = Tbiv
7.33
5.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.58 kW
9.12 kW
Annual energy consumption Qhe
8875 kWh
11076 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
269 %
192 %
Prated
15.20 kW
14.20 kW
SCOP
6.93
5.01
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.94 kW
12.74 kW
COP Tj = -7°C
6.53
4.12
Cdh Tj = -7 °C
0.996
0.998
Pdh Tj = +2°C
14.04 kW
13.22 kW
COP Tj = +2°C
6.89
4.96
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
14.23 kW
13.51 kW
COP Tj = +7°C
7.34
5.61
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.36 kW
13.79 kW
COP Tj = 12°C
7.68
6.31
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
13.94 kW
12.74 kW
COP Tj = Tbiv
6.53
4.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
1.72 kW
Annual energy consumption Qhe
4533 kWh
5856 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.27 kW
9.31 kW
El input
2.16 kW
3.15 kW
COP
4.75
2.96
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
143 %
Prated
10.27 kW
9.39 kW
SCOP
5.23
3.77
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.27 kW
9.31 kW
COP Tj = +2°C
4.75
2.96
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
10.35 kW
9.64 kW
COP Tj = +7°C
5.05
3.43
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.52 kW
10.06 kW
COP Tj = 12°C
5.54
4.29
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
10.27 kW
9.31 kW
COP Tj = Tbiv
4.75
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2623 kWh
3323 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
141 %
Prated
17.18 kW
15.83 kW
SCOP
4.86
3.73
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.48 kW
9.86 kW
COP Tj = -7°C
5.48
3.88
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.55 kW
10.04 kW
COP Tj = +2°C
5.64
4.26
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.60 kW
10.17 kW
COP Tj = +7°C
5.79
4.62
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.60 kW
10.25 kW
COP Tj = 12°C
5.78
4.88
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
10.48 kW
9.86 kW
COP Tj = Tbiv
5.48
3.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.91 kW
6.52 kW
Annual energy consumption Qhe
8717 kWh
10461 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
11.72 kW
10.81 kW
SCOP
5.21
3.95
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.32 kW
9.46 kW
COP Tj = -7°C
4.91
3.19
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.41 kW
9.97 kW
COP Tj = +2°C
5.19
4.10
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.51 kW
10.00 kW
COP Tj = +7°C
5.48
4.18
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.57 kW
10.18 kW
COP Tj = 12°C
5.76
4.64
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
10.32 kW
9.46 kW
COP Tj = Tbiv
4.91
3.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.45 kW
1.50 kW
Annual energy consumption Qhe
4651 kWh
5652 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
13.82 kW
12.48 kW
El input
2.22 kW
3.29 kW
COP
6.23
3.79
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
272 %
192 %
Prated
13.40 kW
12.40 kW
SCOP
7.01
5.00
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.82 kW
12.48 kW
COP Tj = +2°C
6.23
3.79
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
14.02 kW
12.93 kW
COP Tj = +7°C
6.77
4.47
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.26 kW
13.60 kW
COP Tj = 12°C
7.44
5.80
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
13.82 kW
12.48 kW
COP Tj = Tbiv
6.23
3.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2556 kWh
3313 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
241 %
184 %
Prated
22.40 kW
21.60 kW
SCOP
6.22
4.81
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
14.24 kW
13.32 kW
COP Tj = -7°C
7.33
5.18
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
14.29 kW
13.58 kW
COP Tj = +2°C
7.53
5.77
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
14.37 kW
13.79 kW
COP Tj = +7°C
7.73
6.31
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.36 kW
13.95 kW
COP Tj = 12°C
7.74
6.71
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
14.24 kW
13.32 kW
COP Tj = Tbiv
7.33
5.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.58 kW
9.12 kW
Annual energy consumption Qhe
8875 kWh
11076 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
269 %
192 %
Prated
15.20 kW
14.20 kW
SCOP
6.93
5.01
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.94 kW
12.74 kW
COP Tj = -7°C
6.53
4.12
Cdh Tj = -7 °C
0.996
0.998
Pdh Tj = +2°C
14.04 kW
13.22 kW
COP Tj = +2°C
6.89
4.96
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
14.23 kW
13.51 kW
COP Tj = +7°C
7.34
5.61
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.36 kW
13.79 kW
COP Tj = 12°C
7.68
6.31
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
13.94 kW
12.74 kW
COP Tj = Tbiv
6.53
4.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
1.72 kW
Annual energy consumption Qhe
4533 kWh
5856 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.27 kW
9.31 kW
El input
2.16 kW
3.15 kW
COP
4.75
2.96
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
201 %
143 %
Prated
10.27 kW
9.39 kW
SCOP
5.23
3.77
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.27 kW
9.31 kW
COP Tj = +2°C
4.75
2.96
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
10.35 kW
9.64 kW
COP Tj = +7°C
5.05
3.43
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.52 kW
10.06 kW
COP Tj = 12°C
5.54
4.29
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
10.27 kW
9.31 kW
COP Tj = Tbiv
4.75
2.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2623 kWh
3323 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
141 %
Prated
17.18 kW
15.83 kW
SCOP
4.86
3.73
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
10.48 kW
9.86 kW
COP Tj = -7°C
5.48
3.88
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.55 kW
10.04 kW
COP Tj = +2°C
5.64
4.26
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.60 kW
10.17 kW
COP Tj = +7°C
5.79
4.62
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.60 kW
10.25 kW
COP Tj = 12°C
5.78
4.88
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
10.48 kW
9.86 kW
COP Tj = Tbiv
5.48
3.88
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.91 kW
6.52 kW
Annual energy consumption Qhe
8717 kWh
10461 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
46 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
150 %
Prated
11.72 kW
10.81 kW
SCOP
5.21
3.95
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.32 kW
9.46 kW
COP Tj = -7°C
4.91
3.19
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.41 kW
9.97 kW
COP Tj = +2°C
5.19
4.10
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.51 kW
10.00 kW
COP Tj = +7°C
5.48
4.18
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
10.57 kW
10.18 kW
COP Tj = 12°C
5.76
4.64
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
10.32 kW
9.46 kW
COP Tj = Tbiv
4.91
3.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.27 kW
9.31 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.75
2.96
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.45 kW
1.50 kW
Annual energy consumption Qhe
4651 kWh
5652 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
13.82 kW
12.48 kW
El input
2.22 kW
3.29 kW
COP
6.23
3.79
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
272 %
192 %
Prated
13.40 kW
12.40 kW
SCOP
7.01
5.00
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
13.82 kW
12.48 kW
COP Tj = +2°C
6.23
3.79
Cdh Tj = +2 °C
0.997
0.998
Pdh Tj = +7°C
14.02 kW
12.93 kW
COP Tj = +7°C
6.77
4.47
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.26 kW
13.60 kW
COP Tj = 12°C
7.44
5.80
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
13.82 kW
12.48 kW
COP Tj = Tbiv
6.23
3.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2556 kWh
3313 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
241 %
184 %
Prated
22.40 kW
21.60 kW
SCOP
6.22
4.81
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
14.24 kW
13.32 kW
COP Tj = -7°C
7.33
5.18
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
14.29 kW
13.58 kW
COP Tj = +2°C
7.53
5.77
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
14.37 kW
13.79 kW
COP Tj = +7°C
7.73
6.31
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.36 kW
13.95 kW
COP Tj = 12°C
7.74
6.71
Cdh Tj = +12 °C
0.996
0.996
Pdh Tj = Tbiv
14.24 kW
13.32 kW
COP Tj = Tbiv
7.33
5.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
8.58 kW
9.12 kW
Annual energy consumption Qhe
8875 kWh
11076 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
269 %
192 %
Prated
15.20 kW
14.20 kW
SCOP
6.93
5.01
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.94 kW
12.74 kW
COP Tj = -7°C
6.53
4.12
Cdh Tj = -7 °C
0.996
0.998
Pdh Tj = +2°C
14.04 kW
13.22 kW
COP Tj = +2°C
6.89
4.96
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
14.23 kW
13.51 kW
COP Tj = +7°C
7.34
5.61
Cdh Tj = +7 °C
0.996
0.997
Pdh Tj = 12°C
14.36 kW
13.79 kW
COP Tj = 12°C
7.68
6.31
Cdh Tj = +12 °C
0.996
0.997
Pdh Tj = Tbiv
13.94 kW
12.74 kW
COP Tj = Tbiv
6.53
4.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
13.82 kW
12.48 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.23
3.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
7 W
7 W
PSB
7 W
7 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
1.72 kW
Annual energy consumption Qhe
4533 kWh
5856 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.11
Heating up time
1:14 h:min
Standby power input
63.0 W
Reference hot water temperature
54.2 °C
Mixed water at 40°C
302 l