1,700 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.52 kW
6.95 kW
El input
1.68 kW
2.50 kW
COP
4.47
2.79
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
133 %
Prated
7.61 kW
6.92 kW
SCOP
4.89
3.53
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.52 kW
6.95 kW
COP Tj = +2°C
4.47
2.79
Cdh Tj = +2 °C
0.992
0.994
Pdh Tj = +7°C
7.60 kW
7.13 kW
COP Tj = +7°C
4.78
3.23
Cdh Tj = +7 °C
0.991
0.994
Pdh Tj = 12°C
7.70 kW
7.41 kW
COP Tj = 12°C
5.23
4.05
Cdh Tj = +12 °C
0.991
0.992
Pdh Tj = Tbiv
7.52 kW
6.95 kW
COP Tj = Tbiv
4.47
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2080 kWh
2623 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
133 %
Prated
12.50 kW
11.63 kW
SCOP
4.61
3.53
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.68 kW
7.28 kW
COP Tj = -7°C
5.17
3.66
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
7.72 kW
7.40 kW
COP Tj = +2°C
5.32
4.01
Cdh Tj = +2 °C
0.991
0.992
Pdh Tj = +7°C
7.75 kW
7.49 kW
COP Tj = +7°C
5.46
4.35
Cdh Tj = +7 °C
0.990
0.992
Pdh Tj = 12°C
7.75 kW
7.57 kW
COP Tj = 12°C
5.45
4.62
Cdh Tj = +12 °C
0.990
0.991
Pdh Tj = Tbiv
7.68 kW
7.28 kW
COP Tj = Tbiv
5.17
3.66
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.98 kW
4.68 kW
Annual energy consumption Qhe
6682 kWh
8110 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
134 %
Prated
8.60 kW
7.95 kW
SCOP
4.87
3.56
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.55 kW
7.06 kW
COP Tj = -7°C
4.61
3.01
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
7.62 kW
7.24 kW
COP Tj = +2°C
4.89
3.55
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
7.69 kW
7.38 kW
COP Tj = +7°C
5.16
3.94
Cdh Tj = +7 °C
0.991
0.992
Pdh Tj = 12°C
7.75 kW
7.51 kW
COP Tj = 12°C
5.44
4.38
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
7.55 kW
7.06 kW
COP Tj = Tbiv
4.61
3.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.08 kW
1.00 kW
Annual energy consumption Qhe
3646 kWh
4612 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.12 kW
9.19 kW
El input
1.68 kW
2.59 kW
COP
6.04
3.55
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
278 %
177 %
Prated
10.10 kW
9.20 kW
SCOP
7.15
4.62
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.12 kW
9.19 kW
COP Tj = +2°C
6.04
3.55
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.32 kW
9.52 kW
COP Tj = +7°C
6.97
4.22
Cdh Tj = +7 °C
0.995
0.997
Pdh Tj = 12°C
10.42 kW
9.86 kW
COP Tj = 12°C
7.41
5.26
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
10.43 kW
9.19 kW
COP Tj = Tbiv
7.44
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.04
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1887 kWh
2661 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
174 %
241 %
Prated
16.00 kW
22.40 kW
SCOP
4.54
6.22
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.78 kW
14.24 kW
COP Tj = -7°C
4.90
7.33
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
9.95 kW
14.29 kW
COP Tj = +2°C
5.37
7.53
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
10.08 kW
14.37 kW
COP Tj = +7°C
5.85
7.73
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.24 kW
14.36 kW
COP Tj = 12°C
6.35
7.74
Cdh Tj = +12 °C
0.995
0.995
Pdh Tj = Tbiv
9.78 kW
14.24 kW
COP Tj = Tbiv
4.90
7.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.19 kW
13.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.55
6.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.81 kW
8.58 kW
Annual energy consumption Qhe
8684 kWh
8875 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
255 %
179 %
Prated
11.50 kW
10.60 kW
SCOP
6.57
4.66
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.13 kW
9.36 kW
COP Tj = -7°C
6.14
3.87
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.22 kW
9.64 kW
COP Tj = +2°C
6.56
4.56
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
10.30 kW
9.92 kW
COP Tj = +7°C
6.93
5.32
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.49 kW
10.12 kW
COP Tj = 12°C
7.53
5.92
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
10.13 kW
9.36 kW
COP Tj = Tbiv
6.14
3.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.04
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
1.41 kW
Annual energy consumption Qhe
3617 kWh
4695 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.52 kW
6.95 kW
El input
1.68 kW
2.50 kW
COP
4.47
2.79
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
133 %
Prated
7.61 kW
6.92 kW
SCOP
4.89
3.53
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.52 kW
6.95 kW
COP Tj = +2°C
4.47
2.79
Cdh Tj = +2 °C
0.992
0.994
Pdh Tj = +7°C
7.60 kW
7.13 kW
COP Tj = +7°C
4.78
3.23
Cdh Tj = +7 °C
0.991
0.994
Pdh Tj = 12°C
7.70 kW
7.41 kW
COP Tj = 12°C
5.23
4.05
Cdh Tj = +12 °C
0.991
0.992
Pdh Tj = Tbiv
7.52 kW
6.95 kW
COP Tj = Tbiv
4.47
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2080 kWh
2623 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
133 %
Prated
12.50 kW
11.63 kW
SCOP
4.61
3.53
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.68 kW
7.28 kW
COP Tj = -7°C
5.17
3.66
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
7.72 kW
7.40 kW
COP Tj = +2°C
5.32
4.01
Cdh Tj = +2 °C
0.991
0.992
Pdh Tj = +7°C
7.75 kW
7.49 kW
COP Tj = +7°C
5.46
4.35
Cdh Tj = +7 °C
0.990
0.992
Pdh Tj = 12°C
7.75 kW
7.57 kW
COP Tj = 12°C
5.45
4.62
Cdh Tj = +12 °C
0.990
0.991
Pdh Tj = Tbiv
7.68 kW
7.28 kW
COP Tj = Tbiv
5.17
3.66
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.98 kW
4.68 kW
Annual energy consumption Qhe
6682 kWh
8110 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
134 %
Prated
8.60 kW
7.95 kW
SCOP
4.87
3.56
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.55 kW
7.06 kW
COP Tj = -7°C
4.61
3.01
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
7.62 kW
7.24 kW
COP Tj = +2°C
4.89
3.55
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
7.69 kW
7.38 kW
COP Tj = +7°C
5.16
3.94
Cdh Tj = +7 °C
0.991
0.992
Pdh Tj = 12°C
7.75 kW
7.51 kW
COP Tj = 12°C
5.44
4.38
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
7.55 kW
7.06 kW
COP Tj = Tbiv
4.61
3.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.08 kW
1.00 kW
Annual energy consumption Qhe
3646 kWh
4612 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.12 kW
9.19 kW
El input
1.68 kW
2.59 kW
COP
6.04
3.55
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
278 %
177 %
Prated
10.10 kW
9.20 kW
SCOP
7.15
4.62
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.12 kW
9.19 kW
COP Tj = +2°C
6.04
3.55
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.32 kW
9.52 kW
COP Tj = +7°C
6.97
4.22
Cdh Tj = +7 °C
0.995
0.997
Pdh Tj = 12°C
10.42 kW
9.86 kW
COP Tj = 12°C
7.41
5.26
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
10.43 kW
9.19 kW
COP Tj = Tbiv
7.44
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.04
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1887 kWh
2661 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
174 %
241 %
Prated
16.00 kW
22.40 kW
SCOP
4.54
6.22
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.78 kW
14.24 kW
COP Tj = -7°C
4.90
7.33
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
9.95 kW
14.29 kW
COP Tj = +2°C
5.37
7.53
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
10.08 kW
14.37 kW
COP Tj = +7°C
5.85
7.73
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.24 kW
14.36 kW
COP Tj = 12°C
6.35
7.74
Cdh Tj = +12 °C
0.995
0.995
Pdh Tj = Tbiv
9.78 kW
14.24 kW
COP Tj = Tbiv
4.90
7.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.19 kW
13.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.55
6.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.81 kW
8.58 kW
Annual energy consumption Qhe
8684 kWh
8875 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
255 %
179 %
Prated
11.50 kW
10.60 kW
SCOP
6.57
4.66
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.13 kW
9.36 kW
COP Tj = -7°C
6.14
3.87
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.22 kW
9.64 kW
COP Tj = +2°C
6.56
4.56
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
10.30 kW
9.92 kW
COP Tj = +7°C
6.93
5.32
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.49 kW
10.12 kW
COP Tj = 12°C
7.53
5.92
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
10.13 kW
9.36 kW
COP Tj = Tbiv
6.14
3.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.04
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
1.41 kW
Annual energy consumption Qhe
3617 kWh
4695 kWh
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.52 kW
6.95 kW
El input
1.68 kW
2.50 kW
COP
4.47
2.79
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
133 %
Prated
7.61 kW
6.92 kW
SCOP
4.89
3.53
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.52 kW
6.95 kW
COP Tj = +2°C
4.47
2.79
Cdh Tj = +2 °C
0.992
0.994
Pdh Tj = +7°C
7.60 kW
7.13 kW
COP Tj = +7°C
4.78
3.23
Cdh Tj = +7 °C
0.991
0.994
Pdh Tj = 12°C
7.70 kW
7.41 kW
COP Tj = 12°C
5.23
4.05
Cdh Tj = +12 °C
0.991
0.992
Pdh Tj = Tbiv
7.52 kW
6.95 kW
COP Tj = Tbiv
4.47
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2080 kWh
2623 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
133 %
Prated
12.50 kW
11.63 kW
SCOP
4.61
3.53
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.68 kW
7.28 kW
COP Tj = -7°C
5.17
3.66
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
7.72 kW
7.40 kW
COP Tj = +2°C
5.32
4.01
Cdh Tj = +2 °C
0.991
0.992
Pdh Tj = +7°C
7.75 kW
7.49 kW
COP Tj = +7°C
5.46
4.35
Cdh Tj = +7 °C
0.990
0.992
Pdh Tj = 12°C
7.75 kW
7.57 kW
COP Tj = 12°C
5.45
4.62
Cdh Tj = +12 °C
0.990
0.991
Pdh Tj = Tbiv
7.68 kW
7.28 kW
COP Tj = Tbiv
5.17
3.66
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.98 kW
4.68 kW
Annual energy consumption Qhe
6682 kWh
8110 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
134 %
Prated
8.60 kW
7.95 kW
SCOP
4.87
3.56
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.55 kW
7.06 kW
COP Tj = -7°C
4.61
3.01
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
7.62 kW
7.24 kW
COP Tj = +2°C
4.89
3.55
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
7.69 kW
7.38 kW
COP Tj = +7°C
5.16
3.94
Cdh Tj = +7 °C
0.991
0.992
Pdh Tj = 12°C
7.75 kW
7.51 kW
COP Tj = 12°C
5.44
4.38
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
7.55 kW
7.06 kW
COP Tj = Tbiv
4.61
3.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.08 kW
1.00 kW
Annual energy consumption Qhe
3646 kWh
4612 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.12 kW
9.19 kW
El input
1.68 kW
2.59 kW
COP
6.04
3.55
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
278 %
177 %
Prated
10.10 kW
9.20 kW
SCOP
7.15
4.62
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.12 kW
9.19 kW
COP Tj = +2°C
6.04
3.55
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.32 kW
9.52 kW
COP Tj = +7°C
6.97
4.22
Cdh Tj = +7 °C
0.995
0.997
Pdh Tj = 12°C
10.42 kW
9.86 kW
COP Tj = 12°C
7.41
5.26
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
10.43 kW
9.19 kW
COP Tj = Tbiv
7.44
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.04
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1887 kWh
2661 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
174 %
241 %
Prated
16.00 kW
22.40 kW
SCOP
4.54
6.22
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.78 kW
14.24 kW
COP Tj = -7°C
4.90
7.33
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
9.95 kW
14.29 kW
COP Tj = +2°C
5.37
7.53
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
10.08 kW
14.37 kW
COP Tj = +7°C
5.85
7.73
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.24 kW
14.36 kW
COP Tj = 12°C
6.35
7.74
Cdh Tj = +12 °C
0.995
0.995
Pdh Tj = Tbiv
9.78 kW
14.24 kW
COP Tj = Tbiv
4.90
7.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.19 kW
13.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.55
6.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.81 kW
8.58 kW
Annual energy consumption Qhe
8684 kWh
8875 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
255 %
179 %
Prated
11.50 kW
10.60 kW
SCOP
6.57
4.66
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.13 kW
9.36 kW
COP Tj = -7°C
6.14
3.87
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.22 kW
9.64 kW
COP Tj = +2°C
6.56
4.56
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
10.30 kW
9.92 kW
COP Tj = +7°C
6.93
5.32
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.49 kW
10.12 kW
COP Tj = 12°C
7.53
5.92
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
10.13 kW
9.36 kW
COP Tj = Tbiv
6.14
3.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.04
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
1.41 kW
Annual energy consumption Qhe
3617 kWh
4695 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
7.52 kW
6.95 kW
El input
1.68 kW
2.50 kW
COP
4.47
2.79
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
133 %
Prated
7.61 kW
6.92 kW
SCOP
4.89
3.53
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.52 kW
6.95 kW
COP Tj = +2°C
4.47
2.79
Cdh Tj = +2 °C
0.992
0.994
Pdh Tj = +7°C
7.60 kW
7.13 kW
COP Tj = +7°C
4.78
3.23
Cdh Tj = +7 °C
0.991
0.994
Pdh Tj = 12°C
7.70 kW
7.41 kW
COP Tj = 12°C
5.23
4.05
Cdh Tj = +12 °C
0.991
0.992
Pdh Tj = Tbiv
7.52 kW
6.95 kW
COP Tj = Tbiv
4.47
2.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2080 kWh
2623 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
133 %
Prated
12.50 kW
11.63 kW
SCOP
4.61
3.53
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
7.68 kW
7.28 kW
COP Tj = -7°C
5.17
3.66
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
7.72 kW
7.40 kW
COP Tj = +2°C
5.32
4.01
Cdh Tj = +2 °C
0.991
0.992
Pdh Tj = +7°C
7.75 kW
7.49 kW
COP Tj = +7°C
5.46
4.35
Cdh Tj = +7 °C
0.990
0.992
Pdh Tj = 12°C
7.75 kW
7.57 kW
COP Tj = 12°C
5.45
4.62
Cdh Tj = +12 °C
0.990
0.991
Pdh Tj = Tbiv
7.68 kW
7.28 kW
COP Tj = Tbiv
5.17
3.66
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.98 kW
4.68 kW
Annual energy consumption Qhe
6682 kWh
8110 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
43 dB(A)
43 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
134 %
Prated
8.60 kW
7.95 kW
SCOP
4.87
3.56
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
7.55 kW
7.06 kW
COP Tj = -7°C
4.61
3.01
Cdh Tj = -7 °C
0.992
0.994
Pdh Tj = +2°C
7.62 kW
7.24 kW
COP Tj = +2°C
4.89
3.55
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
7.69 kW
7.38 kW
COP Tj = +7°C
5.16
3.94
Cdh Tj = +7 °C
0.991
0.992
Pdh Tj = 12°C
7.75 kW
7.51 kW
COP Tj = 12°C
5.44
4.38
Cdh Tj = +12 °C
0.990
0.992
Pdh Tj = Tbiv
7.55 kW
7.06 kW
COP Tj = Tbiv
4.61
3.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.52 kW
6.95 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.47
2.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.08 kW
1.00 kW
Annual energy consumption Qhe
3646 kWh
4612 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
10.12 kW
9.19 kW
El input
1.68 kW
2.59 kW
COP
6.04
3.55
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
278 %
177 %
Prated
10.10 kW
9.20 kW
SCOP
7.15
4.62
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
10.12 kW
9.19 kW
COP Tj = +2°C
6.04
3.55
Cdh Tj = +2 °C
0.996
0.997
Pdh Tj = +7°C
10.32 kW
9.52 kW
COP Tj = +7°C
6.97
4.22
Cdh Tj = +7 °C
0.995
0.997
Pdh Tj = 12°C
10.42 kW
9.86 kW
COP Tj = 12°C
7.41
5.26
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
10.43 kW
9.19 kW
COP Tj = Tbiv
7.44
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.04
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1887 kWh
2661 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
174 %
241 %
Prated
16.00 kW
22.40 kW
SCOP
4.54
6.22
Tbiv
-7 °C
-7 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
9.78 kW
14.24 kW
COP Tj = -7°C
4.90
7.33
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
9.95 kW
14.29 kW
COP Tj = +2°C
5.37
7.53
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
10.08 kW
14.37 kW
COP Tj = +7°C
5.85
7.73
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.24 kW
14.36 kW
COP Tj = 12°C
6.35
7.74
Cdh Tj = +12 °C
0.995
0.995
Pdh Tj = Tbiv
9.78 kW
14.24 kW
COP Tj = Tbiv
4.90
7.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.19 kW
13.82 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.55
6.23
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
6.81 kW
8.58 kW
Annual energy consumption Qhe
8684 kWh
8875 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
255 %
179 %
Prated
11.50 kW
10.60 kW
SCOP
6.57
4.66
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.13 kW
9.36 kW
COP Tj = -7°C
6.14
3.87
Cdh Tj = -7 °C
0.996
0.997
Pdh Tj = +2°C
10.22 kW
9.64 kW
COP Tj = +2°C
6.56
4.56
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
10.30 kW
9.92 kW
COP Tj = +7°C
6.93
5.32
Cdh Tj = +7 °C
0.995
0.996
Pdh Tj = 12°C
10.49 kW
10.12 kW
COP Tj = 12°C
7.53
5.92
Cdh Tj = +12 °C
0.995
0.996
Pdh Tj = Tbiv
10.13 kW
9.36 kW
COP Tj = Tbiv
6.14
3.87
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.12 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
6.04
3.55
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.996
0.997
WTOL
65 °C
65 °C
Poff
0 W
0 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.38 kW
1.41 kW
Annual energy consumption Qhe
3617 kWh
4695 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
130 %
COP
3.14
Heating up time
1:47 h:min
Standby power input
63.0 W
Reference hot water temperature
54.1 °C
Mixed water at 40°C
293 l