Certificate holders

Subtype

Vitocal 2xx-G B08

Certificate Holder
Viessmann Climate Solutions SE
Viessmannstr. 1
35107 Allendorf/Eder
Germany
Registration number
011-1W0286
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Vitocal 2xx-G B08
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R410A
Mass of Refrigerant

1,700 kg

Certification Date
11.07.2019
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 4

Models

VITOCAL 200-G BWC 201.B08
Configure model
Model name
VITOCAL 200-G BWC 201.B08
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.52 kW

6.95 kW

El input

1.68 kW

2.50 kW

COP

4.47

2.79

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

133 %

Prated

7.61 kW

6.92 kW

SCOP

4.89

3.53

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.52 kW

6.95 kW

COP Tj = +2°C

4.47

2.79

Cdh Tj = +2 °C

0.992

0.994

Pdh Tj = +7°C

7.60 kW

7.13 kW

COP Tj = +7°C

4.78

3.23

Cdh Tj = +7 °C

0.991

0.994

Pdh Tj = 12°C

7.70 kW

7.41 kW

COP Tj = 12°C

5.23

4.05

Cdh Tj = +12 °C

0.991

0.992

Pdh Tj = Tbiv

7.52 kW

6.95 kW

COP Tj = Tbiv

4.47

2.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2080 kWh

2623 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

133 %

Prated

12.50 kW

11.63 kW

SCOP

4.61

3.53

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.68 kW

7.28 kW

COP Tj = -7°C

5.17

3.66

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

7.72 kW

7.40 kW

COP Tj = +2°C

5.32

4.01

Cdh Tj = +2 °C

0.991

0.992

Pdh Tj = +7°C

7.75 kW

7.49 kW

COP Tj = +7°C

5.46

4.35

Cdh Tj = +7 °C

0.990

0.992

Pdh Tj = 12°C

7.75 kW

7.57 kW

COP Tj = 12°C

5.45

4.62

Cdh Tj = +12 °C

0.990

0.991

Pdh Tj = Tbiv

7.68 kW

7.28 kW

COP Tj = Tbiv

5.17

3.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.98 kW

4.68 kW

Annual energy consumption Qhe

6682 kWh

8110 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

134 %

Prated

8.60 kW

7.95 kW

SCOP

4.87

3.56

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.55 kW

7.06 kW

COP Tj = -7°C

4.61

3.01

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

7.62 kW

7.24 kW

COP Tj = +2°C

4.89

3.55

Cdh Tj = +2 °C

0.991

0.993

Pdh Tj = +7°C

7.69 kW

7.38 kW

COP Tj = +7°C

5.16

3.94

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

7.75 kW

7.51 kW

COP Tj = 12°C

5.44

4.38

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

7.55 kW

7.06 kW

COP Tj = Tbiv

4.61

3.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.08 kW

1.00 kW

Annual energy consumption Qhe

3646 kWh

4612 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.12 kW

9.19 kW

El input

1.68 kW

2.59 kW

COP

6.04

3.55

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

278 %

177 %

Prated

10.10 kW

9.20 kW

SCOP

7.15

4.62

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.12 kW

9.19 kW

COP Tj = +2°C

6.04

3.55

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

10.32 kW

9.52 kW

COP Tj = +7°C

6.97

4.22

Cdh Tj = +7 °C

0.995

0.997

Pdh Tj = 12°C

10.42 kW

9.86 kW

COP Tj = 12°C

7.41

5.26

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

10.43 kW

9.19 kW

COP Tj = Tbiv

7.44

3.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.04

3.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1887 kWh

2661 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

174 %

241 %

Prated

16.00 kW

22.40 kW

SCOP

4.54

6.22

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.78 kW

14.24 kW

COP Tj = -7°C

4.90

7.33

Cdh Tj = -7 °C

0.995

0.996

Pdh Tj = +2°C

9.95 kW

14.29 kW

COP Tj = +2°C

5.37

7.53

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

10.08 kW

14.37 kW

COP Tj = +7°C

5.85

7.73

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.24 kW

14.36 kW

COP Tj = 12°C

6.35

7.74

Cdh Tj = +12 °C

0.995

0.995

Pdh Tj = Tbiv

9.78 kW

14.24 kW

COP Tj = Tbiv

4.90

7.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.19 kW

13.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.55

6.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.81 kW

8.58 kW

Annual energy consumption Qhe

8684 kWh

8875 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

255 %

179 %

Prated

11.50 kW

10.60 kW

SCOP

6.57

4.66

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.13 kW

9.36 kW

COP Tj = -7°C

6.14

3.87

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

10.22 kW

9.64 kW

COP Tj = +2°C

6.56

4.56

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

10.30 kW

9.92 kW

COP Tj = +7°C

6.93

5.32

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.49 kW

10.12 kW

COP Tj = 12°C

7.53

5.92

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

10.13 kW

9.36 kW

COP Tj = Tbiv

6.14

3.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.04

3.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.41 kW

Annual energy consumption Qhe

3617 kWh

4695 kWh

VITOCAL 200-G BWC 201.B08 SC
Configure model
Model name
VITOCAL 200-G BWC 201.B08 SC
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.52 kW

6.95 kW

El input

1.68 kW

2.50 kW

COP

4.47

2.79

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

133 %

Prated

7.61 kW

6.92 kW

SCOP

4.89

3.53

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.52 kW

6.95 kW

COP Tj = +2°C

4.47

2.79

Cdh Tj = +2 °C

0.992

0.994

Pdh Tj = +7°C

7.60 kW

7.13 kW

COP Tj = +7°C

4.78

3.23

Cdh Tj = +7 °C

0.991

0.994

Pdh Tj = 12°C

7.70 kW

7.41 kW

COP Tj = 12°C

5.23

4.05

Cdh Tj = +12 °C

0.991

0.992

Pdh Tj = Tbiv

7.52 kW

6.95 kW

COP Tj = Tbiv

4.47

2.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2080 kWh

2623 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

133 %

Prated

12.50 kW

11.63 kW

SCOP

4.61

3.53

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.68 kW

7.28 kW

COP Tj = -7°C

5.17

3.66

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

7.72 kW

7.40 kW

COP Tj = +2°C

5.32

4.01

Cdh Tj = +2 °C

0.991

0.992

Pdh Tj = +7°C

7.75 kW

7.49 kW

COP Tj = +7°C

5.46

4.35

Cdh Tj = +7 °C

0.990

0.992

Pdh Tj = 12°C

7.75 kW

7.57 kW

COP Tj = 12°C

5.45

4.62

Cdh Tj = +12 °C

0.990

0.991

Pdh Tj = Tbiv

7.68 kW

7.28 kW

COP Tj = Tbiv

5.17

3.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.98 kW

4.68 kW

Annual energy consumption Qhe

6682 kWh

8110 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

134 %

Prated

8.60 kW

7.95 kW

SCOP

4.87

3.56

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.55 kW

7.06 kW

COP Tj = -7°C

4.61

3.01

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

7.62 kW

7.24 kW

COP Tj = +2°C

4.89

3.55

Cdh Tj = +2 °C

0.991

0.993

Pdh Tj = +7°C

7.69 kW

7.38 kW

COP Tj = +7°C

5.16

3.94

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

7.75 kW

7.51 kW

COP Tj = 12°C

5.44

4.38

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

7.55 kW

7.06 kW

COP Tj = Tbiv

4.61

3.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.08 kW

1.00 kW

Annual energy consumption Qhe

3646 kWh

4612 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.12 kW

9.19 kW

El input

1.68 kW

2.59 kW

COP

6.04

3.55

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

278 %

177 %

Prated

10.10 kW

9.20 kW

SCOP

7.15

4.62

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.12 kW

9.19 kW

COP Tj = +2°C

6.04

3.55

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

10.32 kW

9.52 kW

COP Tj = +7°C

6.97

4.22

Cdh Tj = +7 °C

0.995

0.997

Pdh Tj = 12°C

10.42 kW

9.86 kW

COP Tj = 12°C

7.41

5.26

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

10.43 kW

9.19 kW

COP Tj = Tbiv

7.44

3.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.04

3.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1887 kWh

2661 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

174 %

241 %

Prated

16.00 kW

22.40 kW

SCOP

4.54

6.22

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.78 kW

14.24 kW

COP Tj = -7°C

4.90

7.33

Cdh Tj = -7 °C

0.995

0.996

Pdh Tj = +2°C

9.95 kW

14.29 kW

COP Tj = +2°C

5.37

7.53

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

10.08 kW

14.37 kW

COP Tj = +7°C

5.85

7.73

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.24 kW

14.36 kW

COP Tj = 12°C

6.35

7.74

Cdh Tj = +12 °C

0.995

0.995

Pdh Tj = Tbiv

9.78 kW

14.24 kW

COP Tj = Tbiv

4.90

7.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.19 kW

13.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.55

6.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.81 kW

8.58 kW

Annual energy consumption Qhe

8684 kWh

8875 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

255 %

179 %

Prated

11.50 kW

10.60 kW

SCOP

6.57

4.66

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.13 kW

9.36 kW

COP Tj = -7°C

6.14

3.87

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

10.22 kW

9.64 kW

COP Tj = +2°C

6.56

4.56

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

10.30 kW

9.92 kW

COP Tj = +7°C

6.93

5.32

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.49 kW

10.12 kW

COP Tj = 12°C

7.53

5.92

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

10.13 kW

9.36 kW

COP Tj = Tbiv

6.14

3.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.04

3.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.41 kW

Annual energy consumption Qhe

3617 kWh

4695 kWh

VITOCAL 222-G BWT 221.B08
Configure model
Model name
VITOCAL 222-G BWT 221.B08
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
Yes

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.52 kW

6.95 kW

El input

1.68 kW

2.50 kW

COP

4.47

2.79

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

133 %

Prated

7.61 kW

6.92 kW

SCOP

4.89

3.53

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.52 kW

6.95 kW

COP Tj = +2°C

4.47

2.79

Cdh Tj = +2 °C

0.992

0.994

Pdh Tj = +7°C

7.60 kW

7.13 kW

COP Tj = +7°C

4.78

3.23

Cdh Tj = +7 °C

0.991

0.994

Pdh Tj = 12°C

7.70 kW

7.41 kW

COP Tj = 12°C

5.23

4.05

Cdh Tj = +12 °C

0.991

0.992

Pdh Tj = Tbiv

7.52 kW

6.95 kW

COP Tj = Tbiv

4.47

2.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2080 kWh

2623 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

133 %

Prated

12.50 kW

11.63 kW

SCOP

4.61

3.53

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.68 kW

7.28 kW

COP Tj = -7°C

5.17

3.66

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

7.72 kW

7.40 kW

COP Tj = +2°C

5.32

4.01

Cdh Tj = +2 °C

0.991

0.992

Pdh Tj = +7°C

7.75 kW

7.49 kW

COP Tj = +7°C

5.46

4.35

Cdh Tj = +7 °C

0.990

0.992

Pdh Tj = 12°C

7.75 kW

7.57 kW

COP Tj = 12°C

5.45

4.62

Cdh Tj = +12 °C

0.990

0.991

Pdh Tj = Tbiv

7.68 kW

7.28 kW

COP Tj = Tbiv

5.17

3.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.98 kW

4.68 kW

Annual energy consumption Qhe

6682 kWh

8110 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

134 %

Prated

8.60 kW

7.95 kW

SCOP

4.87

3.56

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.55 kW

7.06 kW

COP Tj = -7°C

4.61

3.01

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

7.62 kW

7.24 kW

COP Tj = +2°C

4.89

3.55

Cdh Tj = +2 °C

0.991

0.993

Pdh Tj = +7°C

7.69 kW

7.38 kW

COP Tj = +7°C

5.16

3.94

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

7.75 kW

7.51 kW

COP Tj = 12°C

5.44

4.38

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

7.55 kW

7.06 kW

COP Tj = Tbiv

4.61

3.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.08 kW

1.00 kW

Annual energy consumption Qhe

3646 kWh

4612 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.12 kW

9.19 kW

El input

1.68 kW

2.59 kW

COP

6.04

3.55

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

278 %

177 %

Prated

10.10 kW

9.20 kW

SCOP

7.15

4.62

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.12 kW

9.19 kW

COP Tj = +2°C

6.04

3.55

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

10.32 kW

9.52 kW

COP Tj = +7°C

6.97

4.22

Cdh Tj = +7 °C

0.995

0.997

Pdh Tj = 12°C

10.42 kW

9.86 kW

COP Tj = 12°C

7.41

5.26

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

10.43 kW

9.19 kW

COP Tj = Tbiv

7.44

3.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.04

3.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1887 kWh

2661 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

174 %

241 %

Prated

16.00 kW

22.40 kW

SCOP

4.54

6.22

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.78 kW

14.24 kW

COP Tj = -7°C

4.90

7.33

Cdh Tj = -7 °C

0.995

0.996

Pdh Tj = +2°C

9.95 kW

14.29 kW

COP Tj = +2°C

5.37

7.53

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

10.08 kW

14.37 kW

COP Tj = +7°C

5.85

7.73

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.24 kW

14.36 kW

COP Tj = 12°C

6.35

7.74

Cdh Tj = +12 °C

0.995

0.995

Pdh Tj = Tbiv

9.78 kW

14.24 kW

COP Tj = Tbiv

4.90

7.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.19 kW

13.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.55

6.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.81 kW

8.58 kW

Annual energy consumption Qhe

8684 kWh

8875 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

255 %

179 %

Prated

11.50 kW

10.60 kW

SCOP

6.57

4.66

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.13 kW

9.36 kW

COP Tj = -7°C

6.14

3.87

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

10.22 kW

9.64 kW

COP Tj = +2°C

6.56

4.56

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

10.30 kW

9.92 kW

COP Tj = +7°C

6.93

5.32

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.49 kW

10.12 kW

COP Tj = 12°C

7.53

5.92

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

10.13 kW

9.36 kW

COP Tj = Tbiv

6.14

3.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.04

3.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.41 kW

Annual energy consumption Qhe

3617 kWh

4695 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

VITOCAL 222-G BWT 221.B08 SC
Configure model
Model name
VITOCAL 222-G BWT 221.B08 SC
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
Yes

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

7.52 kW

6.95 kW

El input

1.68 kW

2.50 kW

COP

4.47

2.79

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

133 %

Prated

7.61 kW

6.92 kW

SCOP

4.89

3.53

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.52 kW

6.95 kW

COP Tj = +2°C

4.47

2.79

Cdh Tj = +2 °C

0.992

0.994

Pdh Tj = +7°C

7.60 kW

7.13 kW

COP Tj = +7°C

4.78

3.23

Cdh Tj = +7 °C

0.991

0.994

Pdh Tj = 12°C

7.70 kW

7.41 kW

COP Tj = 12°C

5.23

4.05

Cdh Tj = +12 °C

0.991

0.992

Pdh Tj = Tbiv

7.52 kW

6.95 kW

COP Tj = Tbiv

4.47

2.79

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2080 kWh

2623 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

133 %

Prated

12.50 kW

11.63 kW

SCOP

4.61

3.53

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.68 kW

7.28 kW

COP Tj = -7°C

5.17

3.66

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

7.72 kW

7.40 kW

COP Tj = +2°C

5.32

4.01

Cdh Tj = +2 °C

0.991

0.992

Pdh Tj = +7°C

7.75 kW

7.49 kW

COP Tj = +7°C

5.46

4.35

Cdh Tj = +7 °C

0.990

0.992

Pdh Tj = 12°C

7.75 kW

7.57 kW

COP Tj = 12°C

5.45

4.62

Cdh Tj = +12 °C

0.990

0.991

Pdh Tj = Tbiv

7.68 kW

7.28 kW

COP Tj = Tbiv

5.17

3.66

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.98 kW

4.68 kW

Annual energy consumption Qhe

6682 kWh

8110 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

134 %

Prated

8.60 kW

7.95 kW

SCOP

4.87

3.56

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.55 kW

7.06 kW

COP Tj = -7°C

4.61

3.01

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

7.62 kW

7.24 kW

COP Tj = +2°C

4.89

3.55

Cdh Tj = +2 °C

0.991

0.993

Pdh Tj = +7°C

7.69 kW

7.38 kW

COP Tj = +7°C

5.16

3.94

Cdh Tj = +7 °C

0.991

0.992

Pdh Tj = 12°C

7.75 kW

7.51 kW

COP Tj = 12°C

5.44

4.38

Cdh Tj = +12 °C

0.990

0.992

Pdh Tj = Tbiv

7.55 kW

7.06 kW

COP Tj = Tbiv

4.61

3.01

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

6.95 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.47

2.79

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.992

0.994

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.08 kW

1.00 kW

Annual energy consumption Qhe

3646 kWh

4612 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

10.12 kW

9.19 kW

El input

1.68 kW

2.59 kW

COP

6.04

3.55

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

278 %

177 %

Prated

10.10 kW

9.20 kW

SCOP

7.15

4.62

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

10.12 kW

9.19 kW

COP Tj = +2°C

6.04

3.55

Cdh Tj = +2 °C

0.996

0.997

Pdh Tj = +7°C

10.32 kW

9.52 kW

COP Tj = +7°C

6.97

4.22

Cdh Tj = +7 °C

0.995

0.997

Pdh Tj = 12°C

10.42 kW

9.86 kW

COP Tj = 12°C

7.41

5.26

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

10.43 kW

9.19 kW

COP Tj = Tbiv

7.44

3.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.04

3.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1887 kWh

2661 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

174 %

241 %

Prated

16.00 kW

22.40 kW

SCOP

4.54

6.22

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.78 kW

14.24 kW

COP Tj = -7°C

4.90

7.33

Cdh Tj = -7 °C

0.995

0.996

Pdh Tj = +2°C

9.95 kW

14.29 kW

COP Tj = +2°C

5.37

7.53

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

10.08 kW

14.37 kW

COP Tj = +7°C

5.85

7.73

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.24 kW

14.36 kW

COP Tj = 12°C

6.35

7.74

Cdh Tj = +12 °C

0.995

0.995

Pdh Tj = Tbiv

9.78 kW

14.24 kW

COP Tj = Tbiv

4.90

7.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.19 kW

13.82 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.55

6.23

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.81 kW

8.58 kW

Annual energy consumption Qhe

8684 kWh

8875 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

255 %

179 %

Prated

11.50 kW

10.60 kW

SCOP

6.57

4.66

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.13 kW

9.36 kW

COP Tj = -7°C

6.14

3.87

Cdh Tj = -7 °C

0.996

0.997

Pdh Tj = +2°C

10.22 kW

9.64 kW

COP Tj = +2°C

6.56

4.56

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

10.30 kW

9.92 kW

COP Tj = +7°C

6.93

5.32

Cdh Tj = +7 °C

0.995

0.996

Pdh Tj = 12°C

10.49 kW

10.12 kW

COP Tj = 12°C

7.53

5.92

Cdh Tj = +12 °C

0.995

0.996

Pdh Tj = Tbiv

10.13 kW

9.36 kW

COP Tj = Tbiv

6.14

3.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.12 kW

9.19 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.04

3.55

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.996

0.997

WTOL

65 °C

65 °C

Poff

0 W

0 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.41 kW

Annual energy consumption Qhe

3617 kWh

4695 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

130 %

COP

3.14

Heating up time

1:47 h:min

Standby power input

63.0 W

Reference hot water temperature

54.1 °C

Mixed water at 40°C

293 l