Certificate holders

Subtype

HA 7-6 O 230V

Certificate Holder
Saunier Duval Brand Group


Germany
Registration number
011-1W0766
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
HA 7-6 O 230V
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,900 kg

Certification Date
06.04.2022
Testing basis
DIN EN 14511-1:2019-07; EN 14511-1:2018, DIN EN 14511-2:2019-07; EN 14511-2:2018, DIN EN 14511-3:2019-07; EN 14511-3:2018, DIN EN 14511-4:2019-07; EN 14511-4:2018, DIN EN 14825:2019-07; EN 14825:2018, DIN EN 12102-1:2018-02; EN 12102-1:2017
Generate PDF Export model CSV
  • Number of models 6

Models

HA 7-6 O 230V
Configure model
Model name
HA 7-6 O 230V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.57 kW

4.95 kW

El input

0.95 kW

1.68 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

237 %

163 %

Prated

6.77 kW

6.60 kW

SCOP

5.99

4.14

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.77 kW

6.60 kW

COP Tj = +2°C

3.23

2.23

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.14 kW

4.52 kW

COP Tj = +7°C

5.52

3.47

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.75 kW

3.56 kW

COP Tj = 12°C

7.65

5.68

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

6.77 kW

6.60 kW

COP Tj = Tbiv

3.23

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.77 kW

6.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.23

2.23

WTOL

70 °C

70 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1510 kWh

2128 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

118 %

Prated

5.85 kW

5.39 kW

SCOP

4.07

3.03

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.69 kW

COP Tj = -7°C

3.31

2.53

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.73 kW

2.55 kW

COP Tj = +2°C

5.01

3.62

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

3.19 kW

3.08 kW

COP Tj = +7°C

6.82

5.05

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

3.78 kW

3.64 kW

COP Tj = 12°C

8.52

6.54

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

4.77 kW

4.40 kW

COP Tj = Tbiv

2.60

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.94 kW

4.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

70 °C

70 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.85 kW

5.39 kW

Annual energy consumption Qhe

3546 kWh

4380 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.77

4.40

COP Tj = -15°C (if TOL<-20°C)

2.60

1.90

Cdh Tj = -15 °C

0.980

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

134 %

Prated

6.60 kW

6.13 kW

SCOP

4.69

3.43

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.84 kW

5.42 kW

COP Tj = -7°C

2.72

2.13

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.72 kW

3.46 kW

COP Tj = +2°C

4.68

3.36

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

3.18 kW

3.00 kW

COP Tj = +7°C

6.38

4.60

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.74 kW

3.59 kW

COP Tj = 12°C

7.88

6.18

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

6.27 kW

5.42 kW

COP Tj = Tbiv

2.64

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.27 kW

4.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

70 °C

70 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

kW

1.25 kW

Annual energy consumption Qhe

2907 kWh

3688 kWh

HA 7-6 O 230V B2
Configure model
Model name
HA 7-6 O 230V B2
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.57 kW

4.95 kW

El input

0.95 kW

1.68 kW

COP

4.79

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

231 %

160 %

Prated

6.77 kW

6.60 kW

SCOP

5.85

4.07

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.77 kW

6.60 kW

COP Tj = +2°C

3.23

2.23

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.14 kW

4.52 kW

COP Tj = +7°C

5.52

3.47

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.75 kW

3.56 kW

COP Tj = 12°C

7.65

5.68

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

6.77 kW

6.60 kW

COP Tj = Tbiv

3.23

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.77 kW

6.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.23

2.23

WTOL

70 °C

70 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1546 kWh

2164 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

118 %

Prated

5.85 kW

5.39 kW

SCOP

4.05

3.02

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.51 kW

3.69 kW

COP Tj = -7°C

3.31

2.53

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.73 kW

2.55 kW

COP Tj = +2°C

5.01

3.62

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

3.19 kW

3.08 kW

COP Tj = +7°C

6.82

5.05

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

3.78 kW

3.64 kW

COP Tj = 12°C

8.52

6.54

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

4.77 kW

4.40 kW

COP Tj = Tbiv

2.60

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.94 kW

4.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

70 °C

70 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.85 kW

5.39 kW

Annual energy consumption Qhe

3565 kWh

4398 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.77

4.40

COP Tj = -15°C (if TOL<-20°C)

2.60

1.90

Cdh Tj = -15 °C

0.980

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

133 %

Prated

6.60 kW

6.13 kW

SCOP

4.64

3.41

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.84 kW

5.42 kW

COP Tj = -7°C

2.72

2.13

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.72 kW

3.46 kW

COP Tj = +2°C

4.68

3.36

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

3.18 kW

3.00 kW

COP Tj = +7°C

6.38

4.60

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.74 kW

3.59 kW

COP Tj = 12°C

7.88

6.18

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

6.27 kW

5.42 kW

COP Tj = Tbiv

2.64

2.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.27 kW

4.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.64

1.88

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

70 °C

70 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

kW

1.25 kW

Annual energy consumption Qhe

2937 kWh

3718 kWh

HA 8-6 O 230V B3
Configure model
Model name
HA 8-6 O 230V B3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.37 kW

7.58 kW

El input

1.66 kW

2.65 kW

COP

4.42

2.85

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

228 %

162 %

Prated

6.87 kW

7.06 kW

SCOP

5.78

4.13

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.87 kW

7.06 kW

COP Tj = +2°C

3.18

2.31

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.38 kW

4.71 kW

COP Tj = +7°C

5.29

3.44

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

3.68 kW

3.56 kW

COP Tj = 12°C

7.37

5.62

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

6.87 kW

7.06 kW

COP Tj = Tbiv

3.18

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.87 kW

7.06 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.18

2.31

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1586 kWh

2284 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

159 %

119 %

Prated

6.03 kW

5.59 kW

SCOP

4.05

3.06

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.71 kW

3.77 kW

COP Tj = -7°C

3.42

2.54

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.80 kW

2.59 kW

COP Tj = +2°C

5.04

3.70

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

3.25 kW

3.12 kW

COP Tj = +7°C

6.63

5.08

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.73 kW

3.67 kW

COP Tj = 12°C

7.71

6.80

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

4.92 kW

4.56 kW

COP Tj = Tbiv

2.57

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.66 kW

3.29 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.19

1.56

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.03 kW

5.59 kW

Annual energy consumption Qhe

3665 kWh

4506 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.92

4.56

COP Tj = -15°C (if TOL<-20°C)

2.57

1.92

Cdh Tj = -15 °C

0.980

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

135 %

Prated

7.21 kW

6.39 kW

SCOP

4.75

3.44

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.38 kW

5.66 kW

COP Tj = -7°C

2.93

2.17

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.83 kW

3.49 kW

COP Tj = +2°C

4.73

3.32

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

3.21 kW

3.06 kW

COP Tj = +7°C

6.33

4.67

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.72 kW

3.62 kW

COP Tj = 12°C

7.79

6.23

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

6.38 kW

5.66 kW

COP Tj = Tbiv

2.93

2.17

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.00 kW

5.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.66

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.21 kW

1.30 kW

Annual energy consumption Qhe

3139 kWh

3837 kWh

HA 6-6 O 230V
Configure model
Model name
HA 6-6 O 230V
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.48 kW

4.94 kW

El input

0.94 kW

1.69 kW

COP

4.78

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

232 %

164 %

Prated

5.71 kW

6.10 kW

SCOP

5.87

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.71 kW

6.10 kW

COP Tj = +2°C

3.29

2.29

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

3.73 kW

4.28 kW

COP Tj = +7°C

5.59

3.58

Cdh Tj = +7 °C

0.960

0.980

Pdh Tj = 12°C

3.64 kW

3.51 kW

COP Tj = 12°C

7.36

5.59

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

5.71 kW

6.10 kW

COP Tj = Tbiv

3.29

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.71 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.29

2.29

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1299 kWh

1956 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

117 %

Prated

4.25 kW

3.92 kW

SCOP

4.11

3.00

Tbiv

-20 °C

-20 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

2.81 kW

2.28 kW

COP Tj = -7°C

3.51

2.43

Cdh Tj = -7 °C

0.970

0.970

Pdh Tj = +2°C

2.71 kW

2.53 kW

COP Tj = +2°C

5.06

3.72

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

3.10 kW

3.01 kW

COP Tj = +7°C

6.39

4.89

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.69 kW

3.58 kW

COP Tj = 12°C

7.84

6.44

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

4.03 kW

3.71 kW

COP Tj = Tbiv

2.20

1.59

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.03 kW

3.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

1.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.25 kW

3.92 kW

Annual energy consumption Qhe

2549 kWh

3219 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

5.75 kW

4.49 kW

SCOP

4.76

3.35

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.19 kW

3.89 kW

COP Tj = -7°C

3.10

2.19

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

3.01 kW

2.57 kW

COP Tj = +2°C

4.73

3.25

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

3.09 kW

2.95 kW

COP Tj = +7°C

6.17

4.48

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.66 kW

3.56 kW

COP Tj = 12°C

7.60

6.06

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

5.37 kW

4.84 kW

COP Tj = Tbiv

2.78

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.37 kW

4.84 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

kW

kW

Annual energy consumption Qhe

2494 kWh

2766 kWh

HA 6-6 O 230V B2
Configure model
Model name
HA 6-6 O 230V B2
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.48 kW

4.94 kW

El input

0.94 kW

1.69 kW

COP

4.78

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

161 %

Prated

5.71 kW

6.10 kW

SCOP

5.71

4.09

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.71 kW

6.10 kW

COP Tj = +2°C

3.29

2.29

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

3.73 kW

4.28 kW

COP Tj = +7°C

5.59

3.58

Cdh Tj = +7 °C

0.960

0.980

Pdh Tj = 12°C

3.64 kW

3.51 kW

COP Tj = 12°C

7.36

5.59

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

5.71 kW

6.10 kW

COP Tj = Tbiv

3.29

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.71 kW

6.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.29

2.29

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1335 kWh

1993 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

160 %

116 %

Prated

4.25 kW

3.92 kW

SCOP

4.08

2.98

Tbiv

-20 °C

-20 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

2.81 kW

2.28 kW

COP Tj = -7°C

3.51

2.43

Cdh Tj = -7 °C

0.970

0.970

Pdh Tj = +2°C

2.71 kW

2.53 kW

COP Tj = +2°C

5.06

3.72

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

3.10 kW

3.01 kW

COP Tj = +7°C

6.39

4.89

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.69 kW

3.58 kW

COP Tj = 12°C

7.84

6.44

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

4.03 kW

3.71 kW

COP Tj = Tbiv

2.20

1.59

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.03 kW

3.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.20

1.59

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

4.25 kW

3.92 kW

Annual energy consumption Qhe

2567 kWh

3237 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

130 %

Prated

5.75 kW

4.49 kW

SCOP

4.71

3.32

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.19 kW

3.89 kW

COP Tj = -7°C

3.10

2.19

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

3.01 kW

2.57 kW

COP Tj = +2°C

4.73

3.25

Cdh Tj = +2 °C

0.960

0.960

Pdh Tj = +7°C

3.09 kW

2.95 kW

COP Tj = +7°C

6.17

4.48

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.66 kW

3.56 kW

COP Tj = 12°C

7.60

6.06

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

5.37 kW

4.84 kW

COP Tj = Tbiv

2.78

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.37 kW

4.84 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.78

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2524 kWh

2796 kWh

HA 6-6 O 230V B3
Configure model
Model name
HA 6-6 O 230V B3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.12 kW

5.80 kW

El input

1.10 kW

2.00 kW

COP

4.66

2.89

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

229 %

162 %

Prated

5.31 kW

5.98 kW

SCOP

5.81

4.12

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.31 kW

5.98 kW

COP Tj = +2°C

3.46

2.33

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

4.12 kW

3.72 kW

COP Tj = +7°C

5.49

3.50

Cdh Tj = +7 °C

0.96

0.97

Pdh Tj = 12°C

3.67 kW

3.52 kW

COP Tj = 12°C

7.40

5.58

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

5.31 kW

5.98 kW

COP Tj = Tbiv

3.46

2.33

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.31 kW

5.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.46

2.33

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1222 kWh

1938 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

162 %

121 %

Prated

5.97 kW

5.51 kW

SCOP

4.13

3.10

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

3.58 kW

3.27 kW

COP Tj = -7°C

3.45

2.55

Cdh Tj = -7 °C

0.970

0.980

Pdh Tj = +2°C

2.75 kW

2.58 kW

COP Tj = +2°C

5.17

3.80

Cdh Tj = +2 °C

0.950

0.960

Pdh Tj = +7°C

3.16 kW

3.07 kW

COP Tj = +7°C

6.64

5.07

Cdh Tj = +7 °C

0.940

0.960

Pdh Tj = 12°C

3.69 kW

3.60 kW

COP Tj = 12°C

7.77

6.57

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

4.87 kW

4.50 kW

COP Tj = Tbiv

2.57

1.91

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.10 kW

3.76 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.23

1.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.97 kW

5.51 kW

Annual energy consumption Qhe

3560 kWh

4385 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

136 %

Prated

6.73 kW

6.26 kW

SCOP

4.71

3.47

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.96 kW

5.54 kW

COP Tj = -7°C

3.01

2.14

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.67 kW

3.63 kW

COP Tj = +2°C

4.62

3.39

Cdh Tj = +2 °C

0.970

0.970

Pdh Tj = +7°C

3.12 kW

3.01 kW

COP Tj = +7°C

6.36

4.67

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

3.69 kW

3.57 kW

COP Tj = 12°C

7.82

6.19

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

5.96 kW

5.54 kW

COP Tj = Tbiv

3.01

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.52 kW

5.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.77

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

55 °C

55 °C

Poff

8 W

8 W

PTO

29 W

29 W

PSB

29 W

29 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.21 kW

1.21 kW

Annual energy consumption Qhe

2951 kWh

3731 kWh