Certificate holders

Subtype

HA 3-5 OS 230V / HA 5-5 OS 230V

Certificate Holder
Saunier Duval Brand Group


Germany
Registration number
011-1W0762
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
HA 3-5 OS 230V / HA 5-5 OS 230V
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,500 kg

Certification Date
29.04.2021
Testing basis
DIN EN 14511-1:2019-07; EN 14511-1:2018; DIN EN 14511-2:2019-07; EN 14511-2:2018; DIN EN 14511-3:2019-07; EN 14511-3:2018; DIN EN 14511-4:2019-07; EN 14511-4:2018; DIN EN 14825:2019-07; EN 14825:2018; DIN EN 12102-1:2018-02; EN 12102-1:2017
Generate PDF Export model CSV
  • Number of models 4

Models

HA 3-5 OS 230V + HA 5-5 WSB
Configure model
Model name
HA 3-5 OS 230V + HA 5-5 WSB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.13 kW

2.73 kW

El input

0.64 kW

1.05 kW

COP

4.89

2.62

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

51 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

156 %

Prated

3.76 kW

3.31 kW

SCOP

6.41

3.98

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.76 kW

3.31 kW

COP Tj = +2°C

3.69

2.24

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

2.25 kW

2.06 kW

COP Tj = +7°C

5.81

3.36

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.70 kW

2.41 kW

COP Tj = 12°C

8.08

5.31

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.76 kW

3.31 kW

COP Tj = Tbiv

3.69

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.76 kW

3.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.69

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

783 kWh

1111 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

51 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

155 %

107 %

Prated

3.91 kW

2.82 kW

SCOP

3.96

2.76

Tbiv

-13 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

2.36 kW

1.78 kW

COP Tj = -7°C

3.44

2.32

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.96 kW

1.70 kW

COP Tj = +2°C

4.80

3.54

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.34 kW

2.09 kW

COP Tj = +7°C

6.54

4.79

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.68 kW

2.43 kW

COP Tj = 12°C

8.00

6.07

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

2.99 kW

2.30 kW

COP Tj = Tbiv

2.80

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.22 kW

2.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.91 kW

2.82 kW

Annual energy consumption Qhe

2439 kWh

2517 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.22

2.30

COP Tj = -15°C (if TOL<-20°C)

2.17

1.72

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

51 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

130 %

Prated

4.00 kW

3.51 kW

SCOP

4.70

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.10 kW

COP Tj = -7°C

3.19

2.08

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.18 kW

2.04 kW

COP Tj = +2°C

4.50

3.26

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.32 kW

2.02 kW

COP Tj = +7°C

6.15

4.36

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.74 kW

2.44 kW

COP Tj = 12°C

8.42

5.86

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.54 kW

3.10 kW

COP Tj = Tbiv

3.19

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.24 kW

2.75 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.76 kW

0.76 kW

Annual energy consumption Qhe

1758 kWh

2177 kWh

HA 3-5 OS 230V + HA 5-5 STB
Configure model
Model name
HA 3-5 OS 230V + HA 5-5 STB
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.13 kW

2.73 kW

El input

0.64 kW

1.05 kW

COP

4.89

2.62

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

51 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

156 %

Prated

3.76 kW

3.31 kW

SCOP

6.41

3.98

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.76 kW

3.31 kW

COP Tj = +2°C

3.69

2.24

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.25 kW

2.06 kW

COP Tj = +7°C

5.81

3.36

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

2.70 kW

2.41 kW

COP Tj = 12°C

8.08

5.31

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

3.76 kW

3.31 kW

COP Tj = Tbiv

3.69

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.76 kW

3.31 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.69

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

783 kWh

1111 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

51 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

155 %

107 %

Prated

3.91 kW

2.82 kW

SCOP

3.96

2.76

Tbiv

-13 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

2.36 kW

1.78 kW

COP Tj = -7°C

3.44

2.32

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.96 kW

1.70 kW

COP Tj = +2°C

4.80

3.54

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.34 kW

2.09 kW

COP Tj = +7°C

6.54

4.79

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.68 kW

2.43 kW

COP Tj = 12°C

8.00

6.07

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

2.99 kW

2.30 kW

COP Tj = Tbiv

2.80

1.72

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

2.22 kW

2.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.72

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

3.91 kW

2.82 kW

Annual energy consumption Qhe

2439 kWh

2517 kWh

Pdh Tj = -15°C (if TOL<-20°C)

2.22

2.30

COP Tj = -15°C (if TOL<-20°C)

2.17

1.72

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

Sound power level outdoor

51 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

130 %

Prated

4.00 kW

3.51 kW

SCOP

4.70

3.33

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.54 kW

3.10 kW

COP Tj = -7°C

3.19

2.08

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.18 kW

2.04 kW

COP Tj = +2°C

4.50

3.26

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.32 kW

2.02 kW

COP Tj = +7°C

6.15

4.36

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.74 kW

2.44 kW

COP Tj = 12°C

8.42

5.86

Cdh Tj = +12 °C

0.970

0.980

Pdh Tj = Tbiv

3.54 kW

3.10 kW

COP Tj = Tbiv

3.19

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.24 kW

2.75 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.86

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.76 kW

0.76 kW

Annual energy consumption Qhe

1758 kWh

2177 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.88

Heating up time

02:06 h:min

Standby power input

80.0 W

Reference hot water temperature

50.5 °C

Mixed water at 40°C

242 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.55

Heating up time

03:00 h:min

Standby power input

80.0 W

Reference hot water temperature

46.9 °C

Mixed water at 40°C

246 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

102 %

COP

2.45

Heating up time

02:32 h:min

Standby power input

80.0 W

Reference hot water temperature

50.7 °C

Mixed water at 40°C

246 l

HA 5-5 OS 230V + HA 5-5 WSB
Configure model
Model name
HA 5-5 OS 230V + HA 5-5 WSB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.42 kW

3.69 kW

El input

0.95 kW

1.38 kW

COP

4.68

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

156 %

Prated

3.76 kW

3.30 kW

SCOP

6.41

3.98

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.76 kW

3.30 kW

COP Tj = +2°C

3.69

2.24

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.25 kW

2.06 kW

COP Tj = +7°C

5.81

3.36

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

2.70 kW

2.41 kW

COP Tj = 12°C

8.08

5.31

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

3.76 kW

3.30 kW

COP Tj = Tbiv

3.69

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.76 kW

3.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.69

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

783 kWh

1108 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

110 %

Prated

5.19 kW

4.00 kW

SCOP

4.02

2.83

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

2.96 kW

2.44 kW

COP Tj = -7°C

3.41

2.42

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.97 kW

1.72 kW

COP Tj = +2°C

4.87

3.56

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.36 kW

2.11 kW

COP Tj = +7°C

6.57

4.89

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.68 kW

2.52 kW

COP Tj = 12°C

8.00

6.71

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.24 kW

3.26 kW

COP Tj = Tbiv

2.42

1.68

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

3.26 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.19 kW

4.00 kW

Annual energy consumption Qhe

3182 kWh

3485 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.30

3.26

COP Tj = -15°C (if TOL<-20°C)

2.11

1.68

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

41 dB(A)

41 dB(A)

Sound power level outdoor

53 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

135 %

Prated

5.22 kW

5.24 kW

SCOP

4.44

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.83 kW

4.33 kW

COP Tj = -7°C

2.71

2.00

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

2.67 kW

2.57 kW

COP Tj = +2°C

4.26

3.36

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.30 kW

2.09 kW

COP Tj = +7°C

6.06

4.67

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.71 kW

2.52 kW

COP Tj = 12°C

8.39

6.41

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.61 kW

4.63 kW

COP Tj = Tbiv

2.64

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.90 kW

3.72 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.32 kW

1.50 kW

Annual energy consumption Qhe

2427 kWh

3129 kWh

HA 5-5 OS 230V + HA 5-5 STB
Configure model
Model name
HA 5-5 OS 230V + HA 5-5 STB
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.42 kW

3.69 kW

El input

0.95 kW

1.38 kW

COP

4.68

2.67

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

53 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

253 %

156 %

Prated

3.76 kW

3.30 kW

SCOP

6.41

3.98

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

3.76 kW

3.30 kW

COP Tj = +2°C

3.69

2.24

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.25 kW

2.06 kW

COP Tj = +7°C

5.81

3.36

Cdh Tj = +7 °C

0.97

0.98

Pdh Tj = 12°C

2.70 kW

2.41 kW

COP Tj = 12°C

8.08

5.31

Cdh Tj = +12 °C

0.97

0.98

Pdh Tj = Tbiv

3.76 kW

3.30 kW

COP Tj = Tbiv

3.69

2.24

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.76 kW

3.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.69

2.24

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

783 kWh

1108 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

53 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

158 %

110 %

Prated

5.19 kW

4.00 kW

SCOP

4.02

2.83

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

2.96 kW

2.44 kW

COP Tj = -7°C

3.41

2.42

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

1.97 kW

1.72 kW

COP Tj = +2°C

4.87

3.56

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.36 kW

2.11 kW

COP Tj = +7°C

6.57

4.89

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.68 kW

2.52 kW

COP Tj = 12°C

8.00

6.71

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.24 kW

3.26 kW

COP Tj = Tbiv

2.42

1.68

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.30 kW

3.26 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.11

1.68

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.19 kW

4.00 kW

Annual energy consumption Qhe

3182 kWh

3485 kWh

Pdh Tj = -15°C (if TOL<-20°C)

3.30

3.26

COP Tj = -15°C (if TOL<-20°C)

2.11

1.68

Cdh Tj = -15 °C

0.990

0.990

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

43 dB(A)

Sound power level outdoor

53 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

135 %

Prated

5.22 kW

5.24 kW

SCOP

4.44

3.46

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.83 kW

4.33 kW

COP Tj = -7°C

2.71

2.00

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

2.67 kW

2.57 kW

COP Tj = +2°C

4.26

3.36

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

2.30 kW

2.09 kW

COP Tj = +7°C

6.06

4.67

Cdh Tj = +7 °C

0.970

0.980

Pdh Tj = 12°C

2.71 kW

2.52 kW

COP Tj = 12°C

8.39

6.41

Cdh Tj = +12 °C

0.970

0.970

Pdh Tj = Tbiv

4.61 kW

4.63 kW

COP Tj = Tbiv

2.64

2.07

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.90 kW

3.72 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

1.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.32 kW

1.54 kW

Annual energy consumption Qhe

2427 kWh

3129 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

120 %

COP

2.88

Heating up time

02:06 h:min

Standby power input

80.0 W

Reference hot water temperature

50.5 °C

Mixed water at 40°C

242 l

Colder Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

106 %

COP

2.55

Heating up time

03:00 h:min

Standby power input

80.0 W

Reference hot water temperature

46.9 °C

Mixed water at 40°C

246 l

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

1.02 %

COP

2.45

Heating up time

02:32 h:min

Standby power input

80.0 W

Reference hot water temperature

50.7 °C

Mixed water at 40°C

246 l