Certificate holders

Subtype

HA 10-5 OS 230V / HA 12-5 OS 230V / HA 10-5 OS / HA 12-5 OS

Certificate Holder
Saunier Duval Brand Group


Germany
Registration number
011-1W0764
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
HA 10-5 OS 230V / HA 12-5 OS 230V / HA 10-5 OS / HA 12-5 OS
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

3,600 kg

Certification Date
28.04.2021
Testing basis
DIN EN 14511-1:2019-07; EN 14511-1:2018
Generate PDF Export model CSV
  • Number of models 8

Models

HA 10-5 OS 230V + HA 12-5 WSB
Configure model
Model name
HA 10-5 OS 230V + HA 12-5 WSB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.70 kW

10.35 kW

El input

2.12 kW

3.74 kW

COP

4.57

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

158 %

Prated

8.23 kW

9.30 kW

SCOP

5.37

4.03

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.23 kW

9.30 kW

COP Tj = +2°C

3.64

2.42

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.40 kW

5.73 kW

COP Tj = +7°C

4.92

3.37

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.99 kW

6.15 kW

COP Tj = 12°C

6.28

5.20

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

8.23 kW

9.29 kW

COP Tj = Tbiv

3.64

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.23 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.64

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2046 kWh

3076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

111 %

Prated

9.49 kW

9.42 kW

SCOP

3.88

2.86

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

6.32 kW

6.14 kW

COP Tj = -7°C

3.41

2.56

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.94 kW

4.48 kW

COP Tj = +2°C

4.53

3.45

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.53 kW

5.31 kW

COP Tj = +7°C

5.86

4.59

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.44 kW

6.21 kW

COP Tj = 12°C

7.27

5.99

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

7.74 kW

7.68 kW

COP Tj = Tbiv

2.34

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.41 kW

7.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

9.42 kW

Annual energy consumption Qhe

6025 kWh

8124 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.74

7.68

COP Tj = -15°C (if TOL<-20°C)

2.34

1.89

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

128 %

Prated

11.50 kW

9.56 kW

SCOP

4.58

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.18 kW

8.46 kW

COP Tj = -7°C

2.83

2.12

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.53 kW

5.05 kW

COP Tj = +2°C

4.57

3.14

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.66 kW

5.18 kW

COP Tj = +7°C

5.78

4.27

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.52 kW

6.11 kW

COP Tj = 12°C

7.35

5.79

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

10.18 kW

8.46 kW

COP Tj = Tbiv

2.83

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.05 kW

7.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.45 kW

1.59 kW

Annual energy consumption Qhe

5189 kWh

6029 kWh

HA 10-5 OS 230V + HA 12-5 STB
Configure model
Model name
HA 10-5 OS 230V + HA 12-5 STB
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.70 kW

10.35 kW

El input

2.12 kW

3.74 kW

COP

4.57

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

158 %

Prated

8.23 kW

9.30 kW

SCOP

5.37

4.03

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.23 kW

9.30 kW

COP Tj = +2°C

3.64

2.42

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.40 kW

5.73 kW

COP Tj = +7°C

4.92

3.37

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.99 kW

6.15 kW

COP Tj = 12°C

6.28

5.20

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

8.23 kW

9.29 kW

COP Tj = Tbiv

3.64

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.23 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.64

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2046 kWh

3076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

111 %

Prated

9.49 kW

9.42 kW

SCOP

3.88

2.86

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

6.32 kW

6.14 kW

COP Tj = -7°C

3.41

2.56

Cdh Tj = -7 °C

0.990

1.000

Pdh Tj = +2°C

4.94 kW

4.48 kW

COP Tj = +2°C

4.53

3.45

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.53 kW

5.31 kW

COP Tj = +7°C

5.86

4.59

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.44 kW

6.21 kW

COP Tj = 12°C

7.27

5.99

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

7.74 kW

7.68 kW

COP Tj = Tbiv

2.34

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.41 kW

7.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

9.42 kW

Annual energy consumption Qhe

6025 kWh

8124 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.74

7.68

COP Tj = -15°C (if TOL<-20°C)

2.34

1.89

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

128 %

Prated

11.50 kW

9.56 kW

SCOP

4.58

3.28

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.18 kW

8.46 kW

COP Tj = -7°C

2.83

2.12

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.53 kW

5.05 kW

COP Tj = +2°C

4.57

3.14

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.66 kW

5.18 kW

COP Tj = +7°C

5.78

4.27

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.52 kW

6.11 kW

COP Tj = 12°C

7.35

5.79

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

10.18 kW

8.46 kW

COP Tj = Tbiv

2.83

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.05 kW

7.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.45 kW

1.59 kW

Annual energy consumption Qhe

5189 kWh

6029 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

108 %

COP

2.62

Heating up time

01:01 h:min

Standby power input

41.3 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

243 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.14

Heating up time

01:13 h:min

Standby power input

51.6 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

246 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

97 %

COP

2.36

Heating up time

01:04 h:min

Standby power input

44.6 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

244 l

HA 10-5 OS + HA 12-5 WSB
Configure model
Model name
HA 10-5 OS + HA 12-5 WSB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.70 kW

10.35 kW

El input

2.12 kW

3.74 kW

COP

4.57

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

158 %

Prated

8.23 kW

9.29 kW

SCOP

5.34

4.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.23 kW

9.30 kW

COP Tj = +2°C

3.64

2.42

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.40 kW

5.73 kW

COP Tj = +7°C

4.92

3.37

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.99 kW

6.15 kW

COP Tj = 12°C

6.28

5.20

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

8.23 kW

9.29 kW

COP Tj = Tbiv

3.64

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.23 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.64

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2059 kWh

3090 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

111 %

Prated

9.49 kW

9.42 kW

SCOP

3.87

2.85

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

6.32 kW

6.14 kW

COP Tj = -7°C

3.41

2.56

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.94 kW

4.48 kW

COP Tj = +2°C

4.53

3.45

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.53 kW

5.31 kW

COP Tj = +7°C

5.86

4.59

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

6.44 kW

6.21 kW

COP Tj = 12°C

7.27

5.99

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

7.74 kW

7.68 kW

COP Tj = Tbiv

2.34

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.41 kW

7.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

9.42 kW

Annual energy consumption Qhe

6040 kWh

8138 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.74

7.68

COP Tj = -15°C (if TOL<-20°C)

2.34

1.89

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

128 %

Prated

11.50 kW

9.56 kW

SCOP

4.57

3.27

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.18 kW

8.46 kW

COP Tj = -7°C

2.83

2.12

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.53 kW

5.05 kW

COP Tj = +2°C

4.57

3.14

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.66 kW

5.18 kW

COP Tj = +7°C

5.78

4.27

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

6.52 kW

6.11 kW

COP Tj = 12°C

7.35

5.79

Cdh Tj = +12 °C

0.980

0.990

Pdh Tj = Tbiv

10.18 kW

8.46 kW

COP Tj = Tbiv

2.83

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.05 kW

7.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.45 kW

1.59 kW

Annual energy consumption Qhe

5199 kWh

6040 kWh

HA 10-5 OS + HA 12-5 STB
Configure model
Model name
HA 10-5 OS + HA 12-5 STB
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.70 kW

10.35 kW

El input

2.12 kW

3.74 kW

COP

4.57

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

158 %

Prated

8.23 kW

9.29 kW

SCOP

5.34

4.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.23 kW

9.30 kW

COP Tj = +2°C

3.64

2.42

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.40 kW

5.73 kW

COP Tj = +7°C

4.92

3.37

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.99 kW

6.15 kW

COP Tj = 12°C

6.28

5.20

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

8.23 kW

9.29 kW

COP Tj = Tbiv

3.64

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.23 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.64

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2059 kWh

3090 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

111 %

Prated

9.49 kW

9.42 kW

SCOP

3.87

2.85

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

6.32 kW

6.14 kW

COP Tj = -7°C

3.41

2.56

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.94 kW

4.48 kW

COP Tj = +2°C

4.53

3.45

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.53 kW

5.31 kW

COP Tj = +7°C

5.86

4.59

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

6.44 kW

6.21 kW

COP Tj = 12°C

7.27

5.99

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

7.74 kW

7.68 kW

COP Tj = Tbiv

2.34

1.89

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.41 kW

7.68 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.22

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

9.49 kW

9.42 kW

Annual energy consumption Qhe

6040 kWh

8138 kWh

Pdh Tj = -15°C (if TOL<-20°C)

7.74

7.68

COP Tj = -15°C (if TOL<-20°C)

2.34

1.89

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

42 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

180 %

128 %

Prated

11.50 kW

9.56 kW

SCOP

4.57

3.27

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.18 kW

8.46 kW

COP Tj = -7°C

2.83

2.12

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

6.53 kW

5.05 kW

COP Tj = +2°C

4.57

3.14

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.66 kW

5.18 kW

COP Tj = +7°C

5.78

4.27

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

6.52 kW

6.11 kW

COP Tj = 12°C

7.35

5.79

Cdh Tj = +12 °C

0.980

0.990

Pdh Tj = Tbiv

10.18 kW

8.46 kW

COP Tj = Tbiv

2.83

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.05 kW

7.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

1.71

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.45 kW

1.59 kW

Annual energy consumption Qhe

5199 kWh

6040 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

108 %

COP

2.62

Heating up time

01:01 h:min

Standby power input

41.3 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

243 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.14

Heating up time

01:13 h:min

Standby power input

51.6 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

246 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

97 %

COP

2.36

Heating up time

01:04 h:min

Standby power input

44.6 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

244 l

HA 12-5 OS 230V + HA 12-5 WSB
Configure model
Model name
HA 12-5 OS 230V + HA 12-5 WSB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.25 kW

10.90 kW

El input

2.26 kW

3.94 kW

COP

4.54

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

158 %

Prated

8.23 kW

9.29 kW

SCOP

5.37

4.03

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.23 kW

9.30 kW

COP Tj = +2°C

3.64

2.42

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.40 kW

5.73 kW

COP Tj = +7°C

4.92

3.37

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.99 kW

6.15 kW

COP Tj = 12°C

6.28

5.20

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

8.23 kW

9.29 kW

COP Tj = Tbiv

3.64

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.23 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.64

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2046 kWh

3076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

111 %

Prated

12.31 kW

10.28 kW

SCOP

3.91

2.86

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.06 kW

6.50 kW

COP Tj = -7°C

3.40

2.57

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.95 kW

4.47 kW

COP Tj = +2°C

4.68

3.45

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.74 kW

5.33 kW

COP Tj = +7°C

5.94

4.61

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.48 kW

6.10 kW

COP Tj = 12°C

7.01

6.08

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

10.04 kW

8.38 kW

COP Tj = Tbiv

2.27

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.63 kW

8.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

12.31 kW

10.28 kW

Annual energy consumption Qhe

7757 kWh

8863 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.04

8.38

COP Tj = -15°C (if TOL<-20°C)

2.27

1.84

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

133 %

Prated

13.57 kW

10.97 kW

SCOP

4.45

3.39

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.01 kW

9.71 kW

COP Tj = -7°C

2.51

2.16

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.21 kW

5.81 kW

COP Tj = +2°C

4.47

3.25

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.68 kW

5.22 kW

COP Tj = +7°C

5.83

4.47

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.44 kW

6.06 kW

COP Tj = 12°C

7.38

5.85

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.01 kW

9.71 kW

COP Tj = Tbiv

2.51

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.44 kW

8.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.13 kW

2.01 kW

Annual energy consumption Qhe

6303 kWh

6691 kWh

HA 12-5 OS 230V + HA 12-5 STB
Configure model
Model name
HA 12-5 OS 230V + HA 12-5 STB
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.25 kW

10.90 kW

El input

2.26 kW

3.94 kW

COP

4.54

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

44 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

158 %

Prated

8.23 kW

9.29 kW

SCOP

5.37

4.03

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.23 kW

9.30 kW

COP Tj = +2°C

3.64

2.42

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

5.40 kW

5.73 kW

COP Tj = +7°C

4.92

3.37

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.99 kW

6.15 kW

COP Tj = 12°C

6.28

5.20

Cdh Tj = +12 °C

0.99

0.99

Pdh Tj = Tbiv

8.23 kW

9.29 kW

COP Tj = Tbiv

3.64

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.23 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.64

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.00

1.00

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2046 kWh

3076 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

44 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

111 %

Prated

12.31 kW

10.28 kW

SCOP

3.91

2.86

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.06 kW

6.50 kW

COP Tj = -7°C

3.40

2.57

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

4.95 kW

4.47 kW

COP Tj = +2°C

4.68

3.45

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.74 kW

5.33 kW

COP Tj = +7°C

5.94

4.61

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.48 kW

6.10 kW

COP Tj = 12°C

7.01

6.08

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

10.04 kW

8.38 kW

COP Tj = Tbiv

2.27

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.63 kW

8.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

12.31 kW

10.28 kW

Annual energy consumption Qhe

7757 kWh

8863 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.04

8.38

COP Tj = -15°C (if TOL<-20°C)

2.27

1.84

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

44 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

133 %

Prated

13.57 kW

10.97 kW

SCOP

4.45

3.39

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.01 kW

9.71 kW

COP Tj = -7°C

2.51

2.16

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.21 kW

5.81 kW

COP Tj = +2°C

4.47

3.25

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.68 kW

5.22 kW

COP Tj = +7°C

5.83

4.47

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

6.44 kW

6.06 kW

COP Tj = 12°C

7.38

5.85

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

12.01 kW

9.71 kW

COP Tj = Tbiv

2.51

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.44 kW

8.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.13 kW

2.01 kW

Annual energy consumption Qhe

6303 kWh

6691 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

108 %

COP

2.62

Heating up time

01:01 h:min

Standby power input

41.3 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

243 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.14

Heating up time

01:13 h:min

Standby power input

51.6 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

246 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

97 %

COP

2.36

Heating up time

01:04 h:min

Standby power input

44.6 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

244 l

HA 12-5 OS + HA 12-5 WSB
Configure model
Model name
HA 12-5 OS + HA 12-5 WSB
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.25 kW

10.90 kW

El input

2.26 kW

3.94 kW

COP

4.54

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

158 %

Prated

8.23 kW

9.29 kW

SCOP

5.34

4.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.23 kW

9.30 kW

COP Tj = +2°C

3.64

2.42

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.40 kW

5.73 kW

COP Tj = +7°C

4.92

3.37

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.99 kW

6.15 kW

COP Tj = 12°C

6.28

5.20

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

8.23 kW

9.29 kW

COP Tj = Tbiv

3.64

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.23 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.64

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2059 kWh

3090 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

111 %

Prated

12.31 kW

10.28 kW

SCOP

3.91

2.85

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.06 kW

6.50 kW

COP Tj = -7°C

3.40

2.57

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.95 kW

4.47 kW

COP Tj = +2°C

4.68

3.45

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.74 kW

5.33 kW

COP Tj = +7°C

5.94

4.61

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

6.48 kW

6.10 kW

COP Tj = 12°C

7.01

6.08

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

10.04 kW

8.38 kW

COP Tj = Tbiv

2.27

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.63 kW

8.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

12.31 kW

10.28 kW

Annual energy consumption Qhe

7766 kWh

8875 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.04

8.38

COP Tj = -15°C (if TOL<-20°C)

2.27

1.84

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

45 dB(A)

45 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

132 %

Prated

13.57 kW

10.97 kW

SCOP

4.44

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.01 kW

9.71 kW

COP Tj = -7°C

2.51

2.16

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.21 kW

5.81 kW

COP Tj = +2°C

4.47

3.25

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.68 kW

5.22 kW

COP Tj = +7°C

5.83

4.47

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

6.44 kW

6.06 kW

COP Tj = 12°C

7.38

5.85

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

12.01 kW

9.71 kW

COP Tj = Tbiv

2.51

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.44 kW

8.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.13 kW

2.01 kW

Annual energy consumption Qhe

6311 kWh

6700 kWh

HA 12-5 OS + HA 12-5 STB
Configure model
Model name
HA 12-5 OS + HA 12-5 STB
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.25 kW

10.90 kW

El input

2.26 kW

3.94 kW

COP

4.54

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

44 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

211 %

158 %

Prated

8.23 kW

9.29 kW

SCOP

5.34

4.02

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.23 kW

9.30 kW

COP Tj = +2°C

3.64

2.42

Cdh Tj = +2 °C

0.99

1.00

Pdh Tj = +7°C

5.40 kW

5.73 kW

COP Tj = +7°C

4.92

3.37

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

5.99 kW

6.15 kW

COP Tj = 12°C

6.28

5.20

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

8.23 kW

9.29 kW

COP Tj = Tbiv

3.64

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.23 kW

9.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.64

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

1.00

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2059 kWh

3090 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

44 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

111 %

Prated

12.31 kW

10.28 kW

SCOP

3.91

2.85

Tbiv

-15 °C

-15 °C

TOL

-20 °C

-15 °C

Pdh Tj = -7°C

8.06 kW

6.50 kW

COP Tj = -7°C

3.40

2.57

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.95 kW

4.47 kW

COP Tj = +2°C

4.68

3.45

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.74 kW

5.33 kW

COP Tj = +7°C

5.94

4.61

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

6.48 kW

6.10 kW

COP Tj = 12°C

7.01

6.08

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

10.04 kW

8.38 kW

COP Tj = Tbiv

2.27

1.84

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.63 kW

8.38 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.17

1.84

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

12.31 kW

10.28 kW

Annual energy consumption Qhe

7766 kWh

8875 kWh

Pdh Tj = -15°C (if TOL<-20°C)

10.04

8.38

COP Tj = -15°C (if TOL<-20°C)

2.27

1.84

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

43 dB(A)

44 dB(A)

Sound power level outdoor

58 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

175 %

132 %

Prated

13.57 kW

10.97 kW

SCOP

4.44

3.38

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.01 kW

9.71 kW

COP Tj = -7°C

2.51

2.16

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

7.21 kW

5.81 kW

COP Tj = +2°C

4.47

3.25

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.68 kW

5.22 kW

COP Tj = +7°C

5.83

4.47

Cdh Tj = +7 °C

0.980

0.990

Pdh Tj = 12°C

6.44 kW

6.06 kW

COP Tj = 12°C

7.38

5.85

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

12.01 kW

9.71 kW

COP Tj = Tbiv

2.51

2.16

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.44 kW

8.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

17 W

17 W

PTO

17 W

17 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.13 kW

2.01 kW

Annual energy consumption Qhe

6311 kWh

6700 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

108 %

COP

2.62

Heating up time

01:01 h:min

Standby power input

41.3 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

243 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

89 %

COP

2.14

Heating up time

01:13 h:min

Standby power input

51.6 W

Reference hot water temperature

53.4 °C

Mixed water at 40°C

246 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

97 %

COP

2.36

Heating up time

01:04 h:min

Standby power input

44.6 W

Reference hot water temperature

53.7 °C

Mixed water at 40°C

244 l