2,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.41 kW
10.20 kW
El input
2.22 kW
3.22 kW
COP
5.14
3.17
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
0 dB(A)
0 dB(A)
Sound power level outdoor
0 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
217 %
158 %
Prated
15.50 kW
16.00 kW
SCOP
5.49
4.03
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.71 kW
14.49 kW
COP Tj = -7°C
3.34
2.52
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.35 kW
8.62 kW
COP Tj = +2°C
5.31
3.81
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.03 kW
5.54 kW
COP Tj = +7°C
7.35
5.33
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.12 kW
7.04 kW
COP Tj = 12°C
9.57
7.96
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
15.50 kW
16.00 kW
COP Tj = Tbiv
2.74
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
15.50 kW
16.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
13 W
13 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5835 kWh
8201 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
13.15 kW
11.77 kW
El input
2.55 kW
3.67 kW
COP
5.16
3.21
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
0 dB(A)
0 dB(A)
Sound power level outdoor
0 dB(A)
50 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
200 %
158 %
Prated
18.80 kW
18.00 kW
SCOP
5.07
4.02
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
16.70 kW
15.92 kW
COP Tj = -7°C
3.22
2.49
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
10.12 kW
9.69 kW
COP Tj = +2°C
4.59
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.51 kW
6.23 kW
COP Tj = +7°C
7.38
5.35
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.13 kW
7.05 kW
COP Tj = 12°C
9.58
7.97
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
18.80 kW
18.00 kW
COP Tj = Tbiv
2.71
2.08
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
18.80 kW
18.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
2.08
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
13 W
13 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
7650 kWh
9259 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.69 kW
14.98 kW
El input
3.24 kW
4.57 kW
COP
5.15
3.28
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
0 dB(A)
0 dB(A)
Sound power level outdoor
0 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
195 %
142 %
Prated
21.00 kW
22.00 kW
SCOP
4.95
3.62
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
18.50 kW
19.42 kW
COP Tj = -7°C
2.74
2.24
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
10.50 kW
11.85 kW
COP Tj = +2°C
4.60
3.22
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.38 kW
7.62 kW
COP Tj = +7°C
7.59
5.45
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.14 kW
7.05 kW
COP Tj = 12°C
9.60
7.99
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
18.50 kW
19.42 kW
COP Tj = Tbiv
2.74
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
18.50 kW
19.42 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.24
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
13 W
13 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.50 kW
2.58 kW
Annual energy consumption Qhe
8729 kWh
12543 kWh