Certificate holders

Subtype

DE DIETRICH STRATEO 4 MR/E R32

Certificate Holder
BDR Thermea FR (DE DIETRICH)
57 rue de la Gare
67580 Mertzwiller
France
Registration number
007-DM0101
Certification Body
Kiwa Nederland B.V.
Subtype title
DE DIETRICH STRATEO 4 MR/E R32
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

1,200 kg

Certification Date
19.12.2023
Testing basis
European KEYMARK Scheme for Heat Pumps (v10)
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

AWHPR 4 MR + MIC-1C V190 R32
Configure model
Model name
AWHPR 4 MR + MIC-1C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.60 kW

4.10 kW

El input

0.88 kW

1.55 kW

COP

5.20

2.65

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.25 kW

1.12 kW

Cooling capacity

4.50

6.00

EER

3.60

5.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.50 kW

6.00 kW

SEER

4.64

8.02

Pdc Tj = 35°C

4.50 kW

6.00 kW

EER Tj = 35°C

3.60

5.35

Pdc Tj = 30°C

3.32 kW

4.50 kW

EER Tj = 30°C

3.97

7.09

Pdc Tj = 25°C

2.30 kW

2.80 kW

EER Tj = 25°C

5.23

9.20

Pdc Tj = 20°C

1.85 kW

2.85 kW

EER Tj = 20°C

6.40

12.23

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

582 kWh

449 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

134 %

Prated

5.00 kW

5.00 kW

SCOP

4.48

3.43

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.50 kW

COP Tj = -7°C

3.18

2.15

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

4.44

3.39

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

1.75 kW

1.74 kW

COP Tj = +7°C

5.37

4.44

Cdh Tj = +7 °C

0.96

0.96

Pdh Tj = 12°C

2.70 kW

2.10 kW

COP Tj = 12°C

8.78

7.29

Cdh Tj = +12 °C

0.95

0.95

Pdh Tj = Tbiv

5.00 kW

4.50 kW

COP Tj = Tbiv

3.00

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0 kW

0.7 kW

Annual energy consumption Qhe

2305 kWh

3009 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

234 %

163 %

Prated

5.00 kW

5.00 kW

SCOP

5.94

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.51

2.42

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

5.65

3.67

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.10 kW

1.90 kW

COP Tj = 12°C

7.94

5.67

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.51

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.51

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1125 kWh

1607 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

131 %

COP

3.00

Heating up time

1:35 h:min

Standby power input

29.9 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

279 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

169 %

COP

4.00

Heating up time

1:35 h:min

Standby power input

28.9 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

279 l

AWHPR 4 MR + MIC-2C V190 R32
Configure model
Model name
AWHPR 4 MR + MIC-2C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.60 kW

4.10 kW

El input

0.96 kW

1.63 kW

COP

4.82

2.52

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.33 kW

1.20 kW

Cooling capacity

4.50

6.00

EER

3.40

5.01

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.50 kW

6.00 kW

SEER

4.04

6.72

Pdc Tj = 35°C

4.50 kW

6.00 kW

EER Tj = 35°C

3.40

5.01

Pdc Tj = 30°C

3.32 kW

4.50 kW

EER Tj = 30°C

3.64

6.34

Cdc Tj = 30 °C

 

 

Pdc Tj = 25°C

2.30 kW

2.80 kW

EER Tj = 25°C

4.47

7.38

Cdc Tj = 25 °C

 

 

Pdc Tj = 20°C

1.85 kW

2.85 kW

EER Tj = 20°C

5.08

9.25

Cdc Tj = 20 °C

 

 

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

669 kWh

536 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

120 %

Prated

5.00 kW

5.00 kW

SCOP

3.93

3.09

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.50 kW

COP Tj = -7°C

3.02

2.08

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

3.95

3.10

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

1.75 kW

1.74 kW

COP Tj = +7°C

4.37

3.73

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

2.70 kW

2.10 kW

COP Tj = 12°C

7.06

5.78

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

5.00 kW

4.50 kW

COP Tj = Tbiv

2.87

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

2630 kWh

3348 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

198 %

143 %

Prated

5.00 kW

5.00 kW

SCOP

5.03

3.66

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.33

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

5.01

3.39

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.10 kW

1.90 kW

COP Tj = 12°C

6.19

4.63

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.33

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.33

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1328 kWh

1825 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

131 %

COP

3.00

Heating up time

1:35 h:min

Standby power input

29.9 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

279 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

169 %

COP

4.00

Heating up time

1:35 h:min

Standby power input

28.9 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

279 l

AWHPR 4 MR + MIC-1C V190 R32
Configure model
Model name
AWHPR 4 MR + MIC-1C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.60 kW

4.10 kW

El input

0.88 kW

1.55 kW

COP

5.20

2.65

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.25 kW

1.12 kW

Cooling capacity

4.50

6.00

EER

3.60

5.35

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.50 kW

6.00 kW

SEER

4.64

8.02

Pdc Tj = 35°C

4.50 kW

6.00 kW

EER Tj = 35°C

3.60

5.35

Pdc Tj = 30°C

3.32 kW

4.50 kW

EER Tj = 30°C

3.97

7.09

Pdc Tj = 25°C

2.30 kW

2.80 kW

EER Tj = 25°C

5.23

9.20

Pdc Tj = 20°C

1.85 kW

2.85 kW

EER Tj = 20°C

6.40

12.23

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

582 kWh

449 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

134 %

Prated

5.00 kW

5.00 kW

SCOP

4.48

3.43

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.50 kW

COP Tj = -7°C

3.18

2.15

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

4.44

3.39

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

1.75 kW

1.74 kW

COP Tj = +7°C

5.37

4.44

Cdh Tj = +7 °C

0.96

0.96

Pdh Tj = 12°C

2.70 kW

2.10 kW

COP Tj = 12°C

8.78

7.29

Cdh Tj = +12 °C

0.95

0.95

Pdh Tj = Tbiv

5.00 kW

4.50 kW

COP Tj = Tbiv

3.00

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

1.83

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0 kW

0.7 kW

Annual energy consumption Qhe

2305 kWh

3009 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

234 %

163 %

Prated

5.00 kW

5.00 kW

SCOP

5.94

4.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.51

2.42

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

5.65

3.67

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.10 kW

1.90 kW

COP Tj = 12°C

7.94

5.67

Cdh Tj = +12 °C

0.95

0.96

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.51

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.51

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.99

0.99

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: PSUP

0 kW

0 kW

Annual energy consumption Qhe

1125 kWh

1607 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.30

Heating up time

1:35 h:min

Standby power input

31.8 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

279 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

169 %

COP

4.00

Heating up time

1:35 h:min

Standby power input

28.9 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

279 l

AWHPR 4 MR + MIC-2C V190 R32
Configure model
Model name
AWHPR 4 MR + MIC-2C V190 R32
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.60 kW

4.10 kW

El input

0.96 kW

1.63 kW

COP

4.82

2.52

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

1.33 kW

1.20 kW

Cooling capacity

4.50

6.00

EER

3.40

5.01

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

4.50 kW

6.00 kW

SEER

4.04

6.72

Pdc Tj = 35°C

4.50 kW

6.00 kW

EER Tj = 35°C

3.40

5.01

Pdc Tj = 30°C

3.32 kW

4.50 kW

EER Tj = 30°C

3.64

6.34

Cdc Tj = 30 °C

 

 

Pdc Tj = 25°C

2.30 kW

2.80 kW

EER Tj = 25°C

4.47

7.38

Cdc Tj = 25 °C

 

 

Pdc Tj = 20°C

1.85 kW

2.85 kW

EER Tj = 20°C

5.08

9.25

Cdc Tj = 20 °C

 

 

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Annual energy consumption Qce

669 kWh

536 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

32 dB(A)

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

154 %

120 %

Prated

5.00 kW

5.00 kW

SCOP

3.93

3.09

Tbiv

-10 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.40 kW

4.50 kW

COP Tj = -7°C

3.02

2.08

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

2.70 kW

2.70 kW

COP Tj = +2°C

3.95

3.10

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

1.75 kW

1.74 kW

COP Tj = +7°C

4.37

3.73

Cdh Tj = +7 °C

0.960

0.960

Pdh Tj = 12°C

2.70 kW

2.10 kW

COP Tj = 12°C

7.06

5.78

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

5.00 kW

4.50 kW

COP Tj = Tbiv

2.87

2.08

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

4.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

2630 kWh

3348 kWh

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

198 %

143 %

Prated

5.00 kW

5.00 kW

SCOP

5.03

3.66

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.00 kW

5.00 kW

COP Tj = +2°C

3.33

2.34

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

3.30 kW

3.30 kW

COP Tj = +7°C

5.01

3.39

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.10 kW

1.90 kW

COP Tj = 12°C

6.19

4.63

Cdh Tj = +12 °C

0.950

0.960

Pdh Tj = Tbiv

5.00 kW

5.00 kW

COP Tj = Tbiv

3.33

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.33

2.34

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

60 °C

60 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1328 kWh

1825 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

139 %

COP

3.30

Heating up time

1:35 h:min

Standby power input

31.8 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

279 l

Warmer Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

169 %

COP

4.00

Heating up time

1:35 h:min

Standby power input

28.9 W

Reference hot water temperature

53.3 °C

Mixed water at 40°C

279 l