0,950 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
1.97 kW
El input
0.59 kW
0.8 kW
COP
4.81
2.47
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
141 %
Prated
4.3 kW
3.8 kW
SCOP
5.29
3.59
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.3 kW
3.88 kW
COP Tj = +2°C
3.2
2.09
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.63 kW
2.38 kW
COP Tj = +7°C
4.92
3.03
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.67
4.91
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
4.3 kW
3.88 kW
COP Tj = Tbiv
3.2
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.3 kW
3.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.2
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1085 kWh
1414 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
108 %
Prated
3.8 kW
3.2 kW
SCOP
3.99
2.76
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.25 kW
1.84 kW
COP Tj = -7°C
3.4
2.21
Cdh Tj = -7 °C
0.98
0.98
Pdh Tj = +2°C
1.46 kW
1.26 kW
COP Tj = +2°C
4.98
3.41
Cdh Tj = +2 °C
0.95
0.96
Pdh Tj = +7°C
1.6 kW
1.56 kW
COP Tj = +7°C
5.72
4.17
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.8 kW
1.77 kW
COP Tj = 12°C
6.57
5.14
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.11 kW
2.6 kW
COP Tj = Tbiv
2.49
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.2 kW
2.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.35
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.6 kW
1.18 kW
Annual energy consumption Qhe
2345 kWh
2855 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.11
2.6
COP Tj = -15°C (if TOL<-20°C)
2.49
1.78
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
127 %
Prated
4.4 kW
4 kW
SCOP
4.55
3.25
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.89 kW
3.51 kW
COP Tj = -7°C
2.88
2.10
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.23 kW
COP Tj = +2°C
4.46
3.19
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.73 kW
1.53 kW
COP Tj = +7°C
6.12
4.26
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.96 kW
1.82 kW
COP Tj = 12°C
7.37
5.30
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.89 kW
3.51 kW
COP Tj = Tbiv
2.88
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.61 kW
3.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.79 kW
0.90 kW
Annual energy consumption Qhe
1999 kWh
2539 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
98 %
COP
2.21
Heating up time
03:08 h:min
Standby power input
92.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
73 %
COP
1.65
Heating up time
03:25 h:min
Standby power input
120.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
234 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
85 %
COP
1.94
Heating up time
03:08 h:min
Standby power input
93.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
1.97 kW
El input
0.59 kW
0.8 kW
COP
4.81
2.47
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
141 %
Prated
4.3 kW
3.8 kW
SCOP
5.29
3.59
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.3 kW
3.88 kW
COP Tj = +2°C
3.2
2.09
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.63 kW
2.38 kW
COP Tj = +7°C
4.92
3.03
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.67
4.91
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
4.3 kW
3.88 kW
COP Tj = Tbiv
3.2
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.3 kW
3.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.2
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1085 kWh
1414 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
108 %
Prated
3.8 kW
3.2 kW
SCOP
3.99
2.76
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.25 kW
1.84 kW
COP Tj = -7°C
3.4
2.21
Cdh Tj = -7 °C
0.98
0.98
Pdh Tj = +2°C
1.46 kW
1.26 kW
COP Tj = +2°C
4.98
3.41
Cdh Tj = +2 °C
0.95
0.96
Pdh Tj = +7°C
1.6 kW
1.56 kW
COP Tj = +7°C
5.72
4.17
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.8 kW
1.77 kW
COP Tj = 12°C
6.57
5.14
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.11 kW
2.6 kW
COP Tj = Tbiv
2.49
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.2 kW
2.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.35
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.6 kW
1.18 kW
Annual energy consumption Qhe
2345 kWh
2855 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.11
2.6
COP Tj = -15°C (if TOL<-20°C)
2.49
1.78
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
127 %
Prated
4.4 kW
4 kW
SCOP
4.55
3.25
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.89 kW
3.51 kW
COP Tj = -7°C
2.88
2.10
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.23 kW
COP Tj = +2°C
4.46
3.19
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.73 kW
1.53 kW
COP Tj = +7°C
6.12
4.26
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.96 kW
1.82 kW
COP Tj = 12°C
7.37
5.30
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.89 kW
3.51 kW
COP Tj = Tbiv
2.88
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.61 kW
3.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.79 kW
0.90 kW
Annual energy consumption Qhe
1999 kWh
2539 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
98 %
COP
2.21
Heating up time
3:08 h:min
Standby power input
92.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
73 %
COP
1.65
Heating up time
3:25 h:min
Standby power input
120.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
234 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
85 %
COP
1.94
Heating up time
3:08 h:min
Standby power input
93.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
2.02 kW
El input
0.59 kW
0.79 kW
COP
4.85
2.55
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
210 %
143 %
Prated
4.3 kW
3.8 kW
SCOP
5.33
3.66
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.31 kW
3.92 kW
COP Tj = +2°C
3.21
2.12
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.64 kW
2.41 kW
COP Tj = +7°C
4.95
3.09
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.82 kW
1.79 kW
COP Tj = 12°C
6.72
5.01
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
4.31 kW
3.92 kW
COP Tj = Tbiv
3.21
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.31 kW
3.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.21
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1077 kWh
1389 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
109 %
Prated
3.8 kW
3.2 kW
SCOP
4.03
2.81
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.26 kW
1.87 kW
COP Tj = -7°C
3.42
2.27
Cdh Tj = -7 °C
0.98
0.98
Pdh Tj = +2°C
1.46 kW
1.27 kW
COP Tj = +2°C
5.03
3.43
Cdh Tj = +2 °C
0.95
0.96
Pdh Tj = +7°C
1.61 kW
1.58 kW
COP Tj = +7°C
5.76
4.29
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.63
5.25
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.12 kW
2.64 kW
COP Tj = Tbiv
2.51
1.8
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.22 kW
2.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.91
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.58 kW
1.13 kW
Annual energy consumption Qhe
2327 kWh
2807 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.12
2.64
COP Tj = -15°C (if TOL<-20°C)
2.51
1.8
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
130 %
Prated
4.4 kW
4 kW
SCOP
4.58
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.91 kW
3.55 kW
COP Tj = -7°C
2.89
2.12
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.26 kW
COP Tj = +2°C
4.48
3.24
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.73 kW
1.55 kW
COP Tj = +7°C
6.17
4.37
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.97 kW
1.83 kW
COP Tj = 12°C
7.43
5.41
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.91 kW
3.55 kW
COP Tj = Tbiv
2.89
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.63 kW
3.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.77 kW
0.85 kW
Annual energy consumption Qhe
1987 kWh
2492 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
2.02 kW
El input
0.59 kW
0.79 kW
COP
4.85
2.55
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
210 %
143 %
Prated
4.3 kW
3.8 kW
SCOP
5.33
3.66
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.31 kW
3.92 kW
COP Tj = +2°C
3.21
2.12
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.64 kW
2.41 kW
COP Tj = +7°C
4.95
3.09
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.82 kW
1.79 kW
COP Tj = 12°C
6.72
5.01
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
4.31 kW
3.92 kW
COP Tj = Tbiv
3.21
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.31 kW
3.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.21
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1077 kWh
1389 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
109 %
Prated
3.8 kW
3.2 kW
SCOP
4.03
2.81
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.26 kW
1.87 kW
COP Tj = -7°C
3.42
2.27
Cdh Tj = -7 °C
0.98
0.98
Pdh Tj = +2°C
1.46 kW
1.27 kW
COP Tj = +2°C
5.03
3.43
Cdh Tj = +2 °C
0.95
0.96
Pdh Tj = +7°C
1.61 kW
1.58 kW
COP Tj = +7°C
5.76
4.29
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.63
5.25
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.12 kW
2.64 kW
COP Tj = Tbiv
2.51
1.8
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.22 kW
2.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.91
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.58 kW
1.13 kW
Annual energy consumption Qhe
2327 kWh
2807 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.12
2.64
COP Tj = -15°C (if TOL<-20°C)
2.51
1.8
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
130 %
Prated
4.4 kW
4 kW
SCOP
4.58
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.91 kW
3.55 kW
COP Tj = -7°C
2.89
2.12
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.26 kW
COP Tj = +2°C
4.48
3.24
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.73 kW
1.55 kW
COP Tj = +7°C
6.17
4.37
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.97 kW
1.83 kW
COP Tj = 12°C
7.43
5.41
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.91 kW
3.55 kW
COP Tj = Tbiv
2.89
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.63 kW
3.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.77 kW
0.85 kW
Annual energy consumption Qhe
1987 kWh
2492 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
157 %
Prated
6.4 kW
5.9 kW
SCOP
5.56
4
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.43 kW
5.93 kW
COP Tj = +2°C
2.91
2.15
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.14 kW
3.84 kW
COP Tj = +7°C
4.79
3.51
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.95 kW
1.78 kW
COP Tj = 12°C
7.38
5.15
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.43 kW
5.93 kW
COP Tj = Tbiv
2.91
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.43 kW
5.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1538 kWh
1969 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
124 %
Prated
5.4 kW
5.3 kW
SCOP
4.25
3.17
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.45 kW
3.18 kW
COP Tj = -7°C
3.44
2.64
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.1 kW
COP Tj = +2°C
5.47
3.8
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.74 kW
1.71 kW
COP Tj = +7°C
6.25
5.18
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.92 kW
1.9 kW
COP Tj = 12°C
6.87
5.92
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.62 kW
4.3 kW
COP Tj = Tbiv
2.41
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.1
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.39 kW
1.65 kW
Annual energy consumption Qhe
3135 kWh
4116 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.62
4.3
COP Tj = -15°C (if TOL<-20°C)
2.41
1.91
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
137 %
Prated
6.2 kW
6.2 kW
SCOP
4.57
3.5
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.47 kW
5.57 kW
COP Tj = -7°C
2.59
2.11
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.05 kW
3.52 kW
COP Tj = +2°C
4.64
3.39
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.28 kW
2.21 kW
COP Tj = +7°C
6.07
4.84
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.95 kW
1.88 kW
COP Tj = 12°C
7.26
5.83
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.47 kW
5.57 kW
COP Tj = Tbiv
2.59
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.45 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
1.10 kW
Annual energy consumption Qhe
2803 kWh
3657 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
3.18 kW
El input
0.59 kW
1.18 kW
COP
4.81
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
155 %
Prated
6.4 kW
5.9 kW
SCOP
5.53
3.95
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.42 kW
5.89 kW
COP Tj = +2°C
2.9
2.13
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.13 kW
3.81 kW
COP Tj = +7°C
4.77
3.47
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.94 kW
1.77 kW
COP Tj = 12°C
7.32
5.05
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.42 kW
5.89 kW
COP Tj = Tbiv
2.9
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.42 kW
5.89 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.9
2.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1547 kWh
1998 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
122 %
Prated
5.4 kW
5.3 kW
SCOP
4.22
3.13
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.44 kW
3.15 kW
COP Tj = -7°C
3.42
2.61
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.08 kW
COP Tj = +2°C
5.44
3.73
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.74 kW
1.7 kW
COP Tj = +7°C
6.21
5.08
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.91 kW
1.89 kW
COP Tj = 12°C
6.81
5.81
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.61 kW
4.26 kW
COP Tj = Tbiv
2.4
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
1.7 kW
Annual energy consumption Qhe
3152 kWh
4177 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.61
4.26
COP Tj = -15°C (if TOL<-20°C)
2.4
1.89
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
6.2 kW
6.2 kW
SCOP
4.55
3.46
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.46 kW
5.52 kW
COP Tj = -7°C
2.58
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.04 kW
3.49 kW
COP Tj = +2°C
4.61
3.36
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.28 kW
2.20 kW
COP Tj = +7°C
6.04
4.77
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.94 kW
1.87 kW
COP Tj = 12°C
7.20
5.72
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.46 kW
5.52 kW
COP Tj = Tbiv
2.58
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.43 kW
5.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.77 kW
1.15 kW
Annual energy consumption Qhe
2818 kWh
3699 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
106 %
COP
2.48
Heating up time
2:54 h:min
Standby power input
87.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
75 %
COP
1.75
Heating up time
3:11 h:min
Standby power input
131.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
234 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
92 %
COP
2.17
Heating up time
2:54 h:min
Standby power input
87.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
157 %
Prated
6.4 kW
5.9 kW
SCOP
5.56
4
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.43 kW
5.93 kW
COP Tj = +2°C
2.91
2.15
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.14 kW
3.84 kW
COP Tj = +7°C
4.79
3.51
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.95 kW
1.78 kW
COP Tj = 12°C
7.38
5.15
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.43 kW
5.93 kW
COP Tj = Tbiv
2.91
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.43 kW
5.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1538 kWh
1969 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
124 %
Prated
5.4 kW
5.3 kW
SCOP
4.25
3.17
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.45 kW
3.18 kW
COP Tj = -7°C
3.44
2.64
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.1 kW
COP Tj = +2°C
5.47
3.8
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.74 kW
1.71 kW
COP Tj = +7°C
6.25
5.18
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.92 kW
1.9 kW
COP Tj = 12°C
6.87
5.92
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.62 kW
4.3 kW
COP Tj = Tbiv
2.41
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.1
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.39 kW
1.65 kW
Annual energy consumption Qhe
3135 kWh
4116 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.62
4.3
COP Tj = -15°C (if TOL<-20°C)
2.41
1.91
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
137 %
Prated
6.2 kW
6.2 kW
SCOP
4.57
3.5
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.47 kW
5.57 kW
COP Tj = -7°C
2.59
2.11
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.05 kW
3.52 kW
COP Tj = +2°C
4.64
3.39
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.28 kW
2.21 kW
COP Tj = +7°C
6.07
4.84
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.95 kW
1.88 kW
COP Tj = 12°C
7.26
5.83
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.47 kW
5.57 kW
COP Tj = Tbiv
2.59
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.45 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
1.10 kW
Annual energy consumption Qhe
2803 kWh
3657 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
3.18 kW
El input
0.59 kW
1.18 kW
COP
4.81
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
155 %
Prated
6.4 kW
5.9 kW
SCOP
5.53
3.95
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.42 kW
5.89 kW
COP Tj = +2°C
2.9
2.13
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.13 kW
3.81 kW
COP Tj = +7°C
4.77
3.47
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.94 kW
1.77 kW
COP Tj = 12°C
7.32
5.05
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.42 kW
5.89 kW
COP Tj = Tbiv
2.9
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.42 kW
5.89 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.9
2.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1547 kWh
1998 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
122 %
Prated
5.4 kW
5.3 kW
SCOP
4.22
3.13
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.44 kW
3.15 kW
COP Tj = -7°C
3.42
2.61
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.08 kW
COP Tj = +2°C
5.44
3.73
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.74 kW
1.7 kW
COP Tj = +7°C
6.21
5.08
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.91 kW
1.89 kW
COP Tj = 12°C
6.81
5.81
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.61 kW
4.26 kW
COP Tj = Tbiv
2.4
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
1.7 kW
Annual energy consumption Qhe
3152 kWh
4177 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.61
4.26
COP Tj = -15°C (if TOL<-20°C)
2.4
1.89
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
6.2 kW
6.2 kW
SCOP
4.55
3.46
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.46 kW
5.52 kW
COP Tj = -7°C
2.58
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.04 kW
3.49 kW
COP Tj = +2°C
4.61
3.36
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.28 kW
2.20 kW
COP Tj = +7°C
6.04
4.77
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.94 kW
1.87 kW
COP Tj = 12°C
7.20
5.72
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.46 kW
5.52 kW
COP Tj = Tbiv
2.58
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.43 kW
5.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.77 kW
1.15 kW
Annual energy consumption Qhe
2818 kWh
3699 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
106 %
COP
2.48
Heating up time
2:54 h:min
Standby power input
87.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
75 %
COP
1.75
Heating up time
3:11 h:min
Standby power input
131.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
234 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
92 %
COP
2.17
Heating up time
2:54 h:min
Standby power input
87.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
207 %
161 %
Prated
7.1 kW
5.7 kW
SCOP
5.25
4.09
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.08 kW
5.72 kW
COP Tj = +2°C
2.83
2.18
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.67 kW
COP Tj = +7°C
4.23
3.41
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
1.88 kW
1.83 kW
COP Tj = 12°C
7.37
5.59
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
7.08 kW
5.72 kW
COP Tj = Tbiv
2.83
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.08 kW
5.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1807 kWh
1860 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
117 %
Prated
7.3 kW
6.6 kW
SCOP
4.09
3.01
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.07 kW
3.72 kW
COP Tj = -7°C
3.3
2.39
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.38 kW
COP Tj = +2°C
5.2
3.67
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.86 kW
1.84 kW
COP Tj = +7°C
6.24
4.72
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
7
5.53
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.01 kW
5.37 kW
COP Tj = Tbiv
2.38
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.03 kW
3.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.03
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.27 kW
3.32 kW
Annual energy consumption Qhe
4397 kWh
5410 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.01
5.37
COP Tj = -15°C (if TOL<-20°C)
2.38
1.96
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
138 %
Prated
6.6 kW
6.6 kW
SCOP
4.58
3.52
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.42 kW
5.94 kW
COP Tj = -7°C
2.61
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.51 kW
3.53 kW
COP Tj = +2°C
4.68
3.49
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.20 kW
2.45 kW
COP Tj = +7°C
6.09
4.68
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.85 kW
1.80 kW
COP Tj = 12°C
7.23
5.75
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.42 kW
5.94 kW
COP Tj = Tbiv
2.61
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.86 kW
5.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.23
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
1.39 kW
Annual energy consumption Qhe
2975 kWh
3878 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
3.18 kW
El input
0.59 kW
1.18 kW
COP
4.81
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
158 %
Prated
7.1 kW
5.7 kW
SCOP
5.21
4.04
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.08 kW
5.68 kW
COP Tj = +2°C
2.81
2.16
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.64 kW
COP Tj = +7°C
4.2
3.38
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
1.88 kW
1.82 kW
COP Tj = 12°C
7.31
5.48
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
7.08 kW
5.68 kW
COP Tj = Tbiv
2.81
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.08 kW
5.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
2.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1820 kWh
1887 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
116 %
Prated
7.3 kW
6.6 kW
SCOP
4.07
2.97
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.06 kW
3.69 kW
COP Tj = -7°C
3.29
2.36
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.37 kW
COP Tj = +2°C
5.17
3.62
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.86 kW
1.83 kW
COP Tj = +7°C
6.21
4.64
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.83 kW
1.78 kW
COP Tj = 12°C
6.95
5.42
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6 kW
5.33 kW
COP Tj = Tbiv
2.37
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.02
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.29 kW
3.37 kW
Annual energy consumption Qhe
4418 kWh
5475 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6
5.33
COP Tj = -15°C (if TOL<-20°C)
2.37
1.95
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
6.6 kW
6.6 kW
SCOP
4.56
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.41 kW
5.90 kW
COP Tj = -7°C
2.60
2.07
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.50 kW
3.50 kW
COP Tj = +2°C
4.66
3.46
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.20 kW
2.44 kW
COP Tj = +7°C
6.05
4.62
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.85 kW
1.79 kW
COP Tj = 12°C
7.17
5.64
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.41 kW
5.90 kW
COP Tj = Tbiv
2.60
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.85 kW
5.16 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
1.44 kW
Annual energy consumption Qhe
2990 kWh
3917 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
106 %
COP
2.49
Heating up time
2:39 h:min
Standby power input
86.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
75 %
COP
1.75
Heating up time
3:11 h:min
Standby power input
131.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
234 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
92 %
COP
2.17
Heating up time
2:39 h:min
Standby power input
92.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
207 %
161 %
Prated
7.1 kW
5.7 kW
SCOP
5.25
4.09
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.08 kW
5.72 kW
COP Tj = +2°C
2.83
2.18
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.67 kW
COP Tj = +7°C
4.23
3.41
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
1.88 kW
1.83 kW
COP Tj = 12°C
7.37
5.59
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
7.08 kW
5.72 kW
COP Tj = Tbiv
2.83
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.08 kW
5.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1807 kWh
1860 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
117 %
Prated
7.3 kW
6.6 kW
SCOP
4.09
3.01
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.07 kW
3.72 kW
COP Tj = -7°C
3.3
2.39
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.38 kW
COP Tj = +2°C
5.2
3.67
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.86 kW
1.84 kW
COP Tj = +7°C
6.24
4.72
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
7
5.53
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.01 kW
5.37 kW
COP Tj = Tbiv
2.38
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.03 kW
3.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.03
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.27 kW
3.32 kW
Annual energy consumption Qhe
4397 kWh
5410 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.01
5.37
COP Tj = -15°C (if TOL<-20°C)
2.38
1.96
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
138 %
Prated
6.6 kW
6.6 kW
SCOP
4.58
3.52
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.42 kW
5.94 kW
COP Tj = -7°C
2.61
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.51 kW
3.53 kW
COP Tj = +2°C
4.68
3.49
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.20 kW
2.45 kW
COP Tj = +7°C
6.09
4.68
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.85 kW
1.80 kW
COP Tj = 12°C
7.23
5.75
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.42 kW
5.94 kW
COP Tj = Tbiv
2.61
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.86 kW
5.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.23
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
1.39 kW
Annual energy consumption Qhe
2975 kWh
3878 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
3.18 kW
El input
0.59 kW
1.18 kW
COP
4.81
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
158 %
Prated
7.1 kW
5.7 kW
SCOP
5.21
4.04
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.08 kW
5.68 kW
COP Tj = +2°C
2.81
2.16
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.64 kW
COP Tj = +7°C
4.2
3.38
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
1.88 kW
1.82 kW
COP Tj = 12°C
7.31
5.48
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
7.08 kW
5.68 kW
COP Tj = Tbiv
2.81
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.08 kW
5.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
2.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1820 kWh
1887 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
116 %
Prated
7.3 kW
6.6 kW
SCOP
4.07
2.97
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.06 kW
3.69 kW
COP Tj = -7°C
3.29
2.36
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.37 kW
COP Tj = +2°C
5.17
3.62
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.86 kW
1.83 kW
COP Tj = +7°C
6.21
4.64
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.83 kW
1.78 kW
COP Tj = 12°C
6.95
5.42
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6 kW
5.33 kW
COP Tj = Tbiv
2.37
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.02
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.29 kW
3.37 kW
Annual energy consumption Qhe
4418 kWh
5475 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6
5.33
COP Tj = -15°C (if TOL<-20°C)
2.37
1.95
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
6.6 kW
6.6 kW
SCOP
4.56
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.41 kW
5.90 kW
COP Tj = -7°C
2.60
2.07
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.50 kW
3.50 kW
COP Tj = +2°C
4.66
3.46
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.20 kW
2.44 kW
COP Tj = +7°C
6.05
4.62
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.85 kW
1.79 kW
COP Tj = 12°C
7.17
5.64
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.41 kW
5.90 kW
COP Tj = Tbiv
2.60
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.85 kW
5.16 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
1.44 kW
Annual energy consumption Qhe
2990 kWh
3917 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
106 %
COP
2.49
Heating up time
2:39 h:min
Standby power input
86.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
75 %
COP
1.75
Heating up time
3:11 h:min
Standby power input
131.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
234 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
92 %
COP
2.17
Heating up time
2:39 h:min
Standby power input
92.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
1.99 kW
El input
0.59 kW
0.8 kW
COP
4.82
2.51
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
142 %
Prated
4.3 kW
3.8 kW
SCOP
5.30
3.62
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.3 kW
3.79 kW
COP Tj = +2°C
3.2
2.18
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.64 kW
2.4 kW
COP Tj = +7°C
4.93
3.05
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.68
4.93
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
4.3 kW
3.79 kW
COP Tj = Tbiv
3.2
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.3 kW
3.79 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.2
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1083 kWh
1402 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
105 %
Prated
3.8 kW
3.2 kW
SCOP
3.93
2.71
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.26 kW
1.85 kW
COP Tj = -7°C
3.41
2.23
Cdh Tj = -7 °C
0.98
0.98
Pdh Tj = +2°C
1.86 kW
1.77 kW
COP Tj = +2°C
4.78
3.26
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.61 kW
1.56 kW
COP Tj = +7°C
5.73
4.18
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.58
5.16
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.14 kW
2.63 kW
COP Tj = Tbiv
2.56
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.21 kW
2.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.9
1.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.59 kW
1.15 kW
Annual energy consumption Qhe
2385 kWh
2911 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.14
2.63
COP Tj = -15°C (if TOL<-20°C)
2.56
1.79
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
128 %
Prated
4.4 kW
4 kW
SCOP
4.55
3.27
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.90 kW
3.53 kW
COP Tj = -7°C
2.88
2.11
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.25 kW
COP Tj = +2°C
4.47
3.21
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.73 kW
1.54 kW
COP Tj = +7°C
6.13
4.27
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.97 kW
1.83 kW
COP Tj = 12°C
7.38
5.32
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.90 kW
3.53 kW
COP Tj = Tbiv
2.88
3.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.62 kW
3.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.78 kW
0.87 kW
Annual energy consumption Qhe
1996 kWh
2526 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.2 kW
El input
0.59 kW
1.18 kW
COP
4.82
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
155 %
Prated
6.4 kW
5.9 kW
SCOP
5.53
3.96
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.43 kW
5.91 kW
COP Tj = +2°C
2.9
2.14
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.13 kW
3.83 kW
COP Tj = +7°C
4.78
3.49
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.94 kW
1.78 kW
COP Tj = 12°C
7.31
5.06
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.43 kW
5.91 kW
COP Tj = Tbiv
2.9
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.43 kW
5.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.9
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1547 kWh
1990 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
123 %
Prated
5.4 kW
5.3 kW
SCOP
4.24
3.14
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.44 kW
3.16 kW
COP Tj = -7°C
3.43
2.62
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.09 kW
COP Tj = +2°C
5.45
3.75
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.74 kW
1.71 kW
COP Tj = +7°C
6.22
5.1
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.91 kW
1.9 kW
COP Tj = 12°C
6.82
5.83
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.64 kW
4.28 kW
COP Tj = Tbiv
2.45
1.9
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.39 kW
1.67 kW
Annual energy consumption Qhe
3138 kWh
4159 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.64
4.28
COP Tj = -15°C (if TOL<-20°C)
2.45
1.9
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
6.2 kW
6.2 kW
SCOP
4.55
3.47
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.46 kW
5.53 kW
COP Tj = -7°C
2.58
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.04 kW
3.50 kW
COP Tj = +2°C
4.62
3.37
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.28 kW
2.21 kW
COP Tj = +7°C
6.05
4.79
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.94 kW
1.88 kW
COP Tj = 12°C
7.21
5.74
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.46 kW
5.53 kW
COP Tj = Tbiv
2.58
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.44 kW
5.08 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.76 kW
1.12 kW
Annual energy consumption Qhe
2814 kWh
3686 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
1.99 kW
El input
0.59 kW
0.8 kW
COP
4.82
2.51
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
142 %
Prated
4.3 kW
3.8 kW
SCOP
5.30
3.62
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.3 kW
3.79 kW
COP Tj = +2°C
3.2
2.18
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.64 kW
2.4 kW
COP Tj = +7°C
4.93
3.05
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.68
4.93
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
4.3 kW
3.79 kW
COP Tj = Tbiv
3.2
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.3 kW
3.79 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.2
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1083 kWh
1402 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
105 %
Prated
3.8 kW
3.2 kW
SCOP
3.93
2.71
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.26 kW
1.85 kW
COP Tj = -7°C
3.41
2.23
Cdh Tj = -7 °C
0.98
0.98
Pdh Tj = +2°C
1.86 kW
1.77 kW
COP Tj = +2°C
4.78
3.26
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.61 kW
1.56 kW
COP Tj = +7°C
5.73
4.18
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.58
5.16
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.14 kW
2.63 kW
COP Tj = Tbiv
2.56
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.21 kW
2.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.9
1.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.59 kW
1.15 kW
Annual energy consumption Qhe
2385 kWh
2911 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.14
2.63
COP Tj = -15°C (if TOL<-20°C)
2.56
1.79
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
128 %
Prated
4.4 kW
4 kW
SCOP
4.55
3.27
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.90 kW
3.53 kW
COP Tj = -7°C
2.88
2.11
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.25 kW
COP Tj = +2°C
4.47
3.21
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.73 kW
1.54 kW
COP Tj = +7°C
6.13
4.27
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.97 kW
1.83 kW
COP Tj = 12°C
7.38
5.32
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.90 kW
3.53 kW
COP Tj = Tbiv
2.88
3.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.62 kW
3.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.78 kW
0.87 kW
Annual energy consumption Qhe
1996 kWh
2526 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.2 kW
El input
0.59 kW
1.18 kW
COP
4.82
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
155 %
Prated
6.4 kW
5.9 kW
SCOP
5.53
3.96
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.43 kW
5.91 kW
COP Tj = +2°C
2.9
2.14
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.13 kW
3.83 kW
COP Tj = +7°C
4.78
3.49
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.94 kW
1.78 kW
COP Tj = 12°C
7.31
5.06
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.43 kW
5.91 kW
COP Tj = Tbiv
2.9
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.43 kW
5.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.9
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1547 kWh
1990 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
123 %
Prated
5.4 kW
5.3 kW
SCOP
4.24
3.14
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.44 kW
3.16 kW
COP Tj = -7°C
3.43
2.62
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.09 kW
COP Tj = +2°C
5.45
3.75
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.74 kW
1.71 kW
COP Tj = +7°C
6.22
5.1
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.91 kW
1.9 kW
COP Tj = 12°C
6.82
5.83
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.64 kW
4.28 kW
COP Tj = Tbiv
2.45
1.9
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.39 kW
1.67 kW
Annual energy consumption Qhe
3138 kWh
4159 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.64
4.28
COP Tj = -15°C (if TOL<-20°C)
2.45
1.9
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
6.2 kW
6.2 kW
SCOP
4.55
3.47
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.46 kW
5.53 kW
COP Tj = -7°C
2.58
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.04 kW
3.50 kW
COP Tj = +2°C
4.62
3.37
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.28 kW
2.21 kW
COP Tj = +7°C
6.05
4.79
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.94 kW
1.88 kW
COP Tj = 12°C
7.21
5.74
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.46 kW
5.53 kW
COP Tj = Tbiv
2.58
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.44 kW
5.08 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.76 kW
1.12 kW
Annual energy consumption Qhe
2814 kWh
3686 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.2 kW
El input
0.59 kW
1.18 kW
COP
4.82
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
159 %
Prated
7.1 kW
5.7 kW
SCOP
5.22
4.05
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.09 kW
5.7 kW
COP Tj = +2°C
2.82
2.17
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.66 kW
COP Tj = +7°C
4.2
3.39
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
1.88 kW
1.83 kW
COP Tj = 12°C
7.32
5.5
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
7.09 kW
5.7 kW
COP Tj = Tbiv
2.82
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.09 kW
5.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.17
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1818 kWh
1880 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
117 %
Prated
7.3 kW
6.6 kW
SCOP
4.09
2.99
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.06 kW
3.7 kW
COP Tj = -7°C
3.29
2.37
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.38 kW
COP Tj = +2°C
5.18
3.63
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.86 kW
1.59 kW
COP Tj = +7°C
6.21
4.81
Cdh Tj = +7 °C
0.95
0.95
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.99
5.43
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.03 kW
5.35 kW
COP Tj = Tbiv
2.41
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.02 kW
3.26 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.03
1.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.28 kW
3.34 kW
Annual energy consumption Qhe
4400 kWh
5436 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.03
5.35
COP Tj = -15°C (if TOL<-20°C)
2.41
1.95
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
136 %
Prated
6.6 kW
6.6 kW
SCOP
4.56
3.49
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.42 kW
5.98 kW
COP Tj = -7°C
2.60
2.05
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.51 kW
3.51 kW
COP Tj = +2°C
4.67
3.47
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.20 kW
2.45 kW
COP Tj = +7°C
6.06
4.63
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.85 kW
1.80 kW
COP Tj = 12°C
7.14
5.66
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.42 kW
5.98 kW
COP Tj = Tbiv
2.60
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.86 kW
5.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
60 °C
60 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
1.41 kW
Annual energy consumption Qhe
2987 kWh
3912 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.2 kW
El input
0.59 kW
1.18 kW
COP
4.82
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
159 %
Prated
7.1 kW
5.7 kW
SCOP
5.22
4.05
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.09 kW
5.7 kW
COP Tj = +2°C
2.82
2.17
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.66 kW
COP Tj = +7°C
4.2
3.39
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
1.88 kW
1.83 kW
COP Tj = 12°C
7.32
5.5
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
7.09 kW
5.7 kW
COP Tj = Tbiv
2.82
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.09 kW
5.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.17
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1818 kWh
1880 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
117 %
Prated
7.3 kW
6.6 kW
SCOP
4.09
2.99
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.06 kW
3.7 kW
COP Tj = -7°C
3.29
2.37
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.38 kW
COP Tj = +2°C
5.18
3.63
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.86 kW
1.59 kW
COP Tj = +7°C
6.21
4.81
Cdh Tj = +7 °C
0.95
0.95
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.99
5.43
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.03 kW
5.35 kW
COP Tj = Tbiv
2.41
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.02 kW
3.26 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.03
1.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.28 kW
3.34 kW
Annual energy consumption Qhe
4400 kWh
5436 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.03
5.35
COP Tj = -15°C (if TOL<-20°C)
2.41
1.95
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
136 %
Prated
6.6 kW
6.6 kW
SCOP
4.56
3.49
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.42 kW
5.98 kW
COP Tj = -7°C
2.60
2.05
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.51 kW
3.51 kW
COP Tj = +2°C
4.67
3.47
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.20 kW
2.45 kW
COP Tj = +7°C
6.06
4.63
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.85 kW
1.80 kW
COP Tj = 12°C
7.14
5.66
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.42 kW
5.98 kW
COP Tj = Tbiv
2.60
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.86 kW
5.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
1.41 kW
Annual energy consumption Qhe
2987 kWh
3912 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
2.02 kW
El input
0.59 kW
0.79 kW
COP
4.85
2.55
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
210 %
143 %
Prated
4.3 kW
3.8 kW
SCOP
5.33
3.66
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.31 kW
3.92 kW
COP Tj = +2°C
3.21
2.12
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.64 kW
2.41 kW
COP Tj = +7°C
4.95
3.09
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.82 kW
1.79 kW
COP Tj = 12°C
6.72
5.01
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
4.31 kW
3.92 kW
COP Tj = Tbiv
3.21
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.31 kW
3.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.21
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1077 kWh
1389 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
109 %
Prated
3.8 kW
3.2 kW
SCOP
4.03
2.81
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.26 kW
1.87 kW
COP Tj = -7°C
3.42
2.27
Cdh Tj = -7 °C
0.98
0.98
Pdh Tj = +2°C
1.46 kW
1.27 kW
COP Tj = +2°C
5.03
3.43
Cdh Tj = +2 °C
0.95
0.96
Pdh Tj = +7°C
1.61 kW
1.58 kW
COP Tj = +7°C
5.76
4.29
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.63
5.25
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.12 kW
2.64 kW
COP Tj = Tbiv
2.51
1.8
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.22 kW
2.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.91
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.58 kW
1.13 kW
Annual energy consumption Qhe
2327 kWh
2807 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.12
2.64
COP Tj = -15°C (if TOL<-20°C)
2.51
1.8
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
130 %
Prated
4.4 kW
4 kW
SCOP
4.58
3.32
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.91 kW
3.55 kW
COP Tj = -7°C
2.89
2.12
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.26 kW
COP Tj = +2°C
4.48
3.24
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.73 kW
1.55 kW
COP Tj = +7°C
6.17
4.37
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.97 kW
1.83 kW
COP Tj = 12°C
7.43
5.41
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.91 kW
3.55 kW
COP Tj = Tbiv
2.89
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.63 kW
3.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.77 kW
0.85 kW
Annual energy consumption Qhe
1987 kWh
2492 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
1.97 kW
El input
0.59 kW
0.8 kW
COP
4.81
2.47
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
141 %
Prated
4.3 kW
3.8 kW
SCOP
5.29
3.59
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.3 kW
3.88 kW
COP Tj = +2°C
3.2
2.09
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.63 kW
2.38 kW
COP Tj = +7°C
4.92
3.03
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.67
4.91
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
4.3 kW
3.88 kW
COP Tj = Tbiv
3.2
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.3 kW
3.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.2
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1085 kWh
1414 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
157 %
108 %
Prated
3.8 kW
3.2 kW
SCOP
3.99
2.76
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.25 kW
1.84 kW
COP Tj = -7°C
3.4
2.21
Cdh Tj = -7 °C
0.98
0.98
Pdh Tj = +2°C
1.46 kW
1.26 kW
COP Tj = +2°C
4.98
3.41
Cdh Tj = +2 °C
0.95
0.96
Pdh Tj = +7°C
1.6 kW
1.56 kW
COP Tj = +7°C
5.72
4.17
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.8 kW
1.77 kW
COP Tj = 12°C
6.57
5.14
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.11 kW
2.6 kW
COP Tj = Tbiv
2.49
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.2 kW
2.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.35
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.6 kW
1.18 kW
Annual energy consumption Qhe
2345 kWh
2855 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.11
2.6
COP Tj = -15°C (if TOL<-20°C)
2.49
1.78
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
127 %
Prated
4.4 kW
4 kW
SCOP
4.55
3.25
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.89 kW
3.51 kW
COP Tj = -7°C
2.88
2.10
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.23 kW
COP Tj = +2°C
4.46
3.19
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.73 kW
1.53 kW
COP Tj = +7°C
6.12
4.26
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.96 kW
1.82 kW
COP Tj = 12°C
7.37
5.30
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.89 kW
3.51 kW
COP Tj = Tbiv
2.88
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.61 kW
3.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.79 kW
0.90 kW
Annual energy consumption Qhe
1999 kWh
2539 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
98 %
COP
2.21
Heating up time
3:08 h:min
Standby power input
92.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Colder Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
73 %
COP
1.65
Heating up time
3:25 h:min
Standby power input
120.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
234 l
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
85 %
COP
1.94
Heating up time
3:08 h:min
Standby power input
93.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
1.99 kW
El input
0.59 kW
0.8 kW
COP
4.82
2.51
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
209 %
142 %
Prated
4.3 kW
3.8 kW
SCOP
5.30
3.62
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.3 kW
3.79 kW
COP Tj = +2°C
3.2
2.18
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.64 kW
2.4 kW
COP Tj = +7°C
4.93
3.05
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.68
4.93
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
4.3 kW
3.79 kW
COP Tj = Tbiv
3.2
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.3 kW
3.79 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.2
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1083 kWh
1402 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
154 %
105 %
Prated
3.8 kW
3.2 kW
SCOP
3.93
2.71
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.26 kW
1.85 kW
COP Tj = -7°C
3.41
2.23
Cdh Tj = -7 °C
0.98
0.98
Pdh Tj = +2°C
1.86 kW
1.77 kW
COP Tj = +2°C
4.78
3.26
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.61 kW
1.56 kW
COP Tj = +7°C
5.73
4.18
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.58
5.16
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.14 kW
2.63 kW
COP Tj = Tbiv
2.56
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.21 kW
2.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.9
1.37
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.59 kW
1.15 kW
Annual energy consumption Qhe
2385 kWh
2911 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.14
2.63
COP Tj = -15°C (if TOL<-20°C)
2.56
1.79
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
128 %
Prated
4.4 kW
4 kW
SCOP
4.55
3.27
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.90 kW
3.53 kW
COP Tj = -7°C
2.88
2.11
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.25 kW
COP Tj = +2°C
4.47
3.21
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.73 kW
1.54 kW
COP Tj = +7°C
6.13
4.27
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.97 kW
1.83 kW
COP Tj = 12°C
7.38
5.32
Cdh Tj = +12 °C
0.95
0.96
Pdh Tj = Tbiv
3.90 kW
3.53 kW
COP Tj = Tbiv
2.88
3.53
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.62 kW
3.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
14 W
14 W
PSB
15 W
15 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.78 kW
0.87 kW
Annual energy consumption Qhe
1996 kWh
2526 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
219 %
157 %
Prated
6.4 kW
5.9 kW
SCOP
5.56
4
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.43 kW
5.93 kW
COP Tj = +2°C
2.91
2.15
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.14 kW
3.84 kW
COP Tj = +7°C
4.79
3.51
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.95 kW
1.78 kW
COP Tj = 12°C
7.38
5.15
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.43 kW
5.93 kW
COP Tj = Tbiv
2.91
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.43 kW
5.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1538 kWh
1969 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
124 %
Prated
5.4 kW
5.3 kW
SCOP
4.25
3.17
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.45 kW
3.18 kW
COP Tj = -7°C
3.44
2.64
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.1 kW
COP Tj = +2°C
5.47
3.8
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.74 kW
1.71 kW
COP Tj = +7°C
6.25
5.18
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.92 kW
1.9 kW
COP Tj = 12°C
6.87
5.92
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.62 kW
4.3 kW
COP Tj = Tbiv
2.41
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.1
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.39 kW
1.65 kW
Annual energy consumption Qhe
3135 kWh
4116 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.62
4.3
COP Tj = -15°C (if TOL<-20°C)
2.41
1.91
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
137 %
Prated
6.2 kW
6.2 kW
SCOP
4.57
3.5
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.47 kW
5.57 kW
COP Tj = -7°C
2.59
2.11
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.05 kW
3.52 kW
COP Tj = +2°C
4.64
3.39
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.28 kW
2.21 kW
COP Tj = +7°C
6.07
4.84
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.95 kW
1.88 kW
COP Tj = 12°C
7.26
5.83
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.47 kW
5.57 kW
COP Tj = Tbiv
2.59
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.45 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
1.10 kW
Annual energy consumption Qhe
2803 kWh
3657 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
3.18 kW
El input
0.59 kW
1.18 kW
COP
4.81
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
155 %
Prated
6.4 kW
5.9 kW
SCOP
5.53
3.95
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.42 kW
5.89 kW
COP Tj = +2°C
2.9
2.13
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.13 kW
3.81 kW
COP Tj = +7°C
4.77
3.47
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.94 kW
1.77 kW
COP Tj = 12°C
7.32
5.05
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.42 kW
5.89 kW
COP Tj = Tbiv
2.9
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.42 kW
5.89 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.9
2.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1547 kWh
1998 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
122 %
Prated
5.4 kW
5.3 kW
SCOP
4.22
3.13
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.44 kW
3.15 kW
COP Tj = -7°C
3.42
2.61
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.08 kW
COP Tj = +2°C
5.44
3.73
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.74 kW
1.7 kW
COP Tj = +7°C
6.21
5.08
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.91 kW
1.89 kW
COP Tj = 12°C
6.81
5.81
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.61 kW
4.26 kW
COP Tj = Tbiv
2.4
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4 kW
3.6 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.4 kW
1.7 kW
Annual energy consumption Qhe
3152 kWh
4177 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.61
4.26
COP Tj = -15°C (if TOL<-20°C)
2.4
1.89
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
6.2 kW
6.2 kW
SCOP
4.55
3.46
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.46 kW
5.52 kW
COP Tj = -7°C
2.58
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.04 kW
3.49 kW
COP Tj = +2°C
4.61
3.36
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.28 kW
2.20 kW
COP Tj = +7°C
6.04
4.77
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.94 kW
1.87 kW
COP Tj = 12°C
7.20
5.72
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.46 kW
5.52 kW
COP Tj = Tbiv
2.58
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.43 kW
5.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.87
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.77 kW
1.15 kW
Annual energy consumption Qhe
2818 kWh
3699 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
106 %
COP
2.48
Heating up time
2:54 h:min
Standby power input
87.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
75 %
COP
1.75
Heating up time
3:11 h:min
Standby power input
131.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
234 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
92 %
COP
2.17
Heating up time
2:54 h:min
Standby power input
87.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.2 kW
El input
0.59 kW
1.18 kW
COP
4.82
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
218 %
155 %
Prated
6.4 kW
5.9 kW
SCOP
5.53
3.96
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.43 kW
5.91 kW
COP Tj = +2°C
2.9
2.14
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.13 kW
3.83 kW
COP Tj = +7°C
4.78
3.49
Cdh Tj = +7 °C
0.98
0.99
Pdh Tj = 12°C
1.94 kW
1.78 kW
COP Tj = 12°C
7.31
5.06
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.43 kW
5.91 kW
COP Tj = Tbiv
2.9
2.14
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.43 kW
5.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.9
2.14
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1547 kWh
1990 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
123 %
Prated
5.4 kW
5.3 kW
SCOP
4.24
3.14
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.44 kW
3.16 kW
COP Tj = -7°C
3.43
2.62
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.09 kW
COP Tj = +2°C
5.45
3.75
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.74 kW
1.71 kW
COP Tj = +7°C
6.22
5.1
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.91 kW
1.9 kW
COP Tj = 12°C
6.82
5.83
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
4.64 kW
4.28 kW
COP Tj = Tbiv
2.45
1.9
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.09
1.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.39 kW
1.67 kW
Annual energy consumption Qhe
3138 kWh
4159 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.64
4.28
COP Tj = -15°C (if TOL<-20°C)
2.45
1.9
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
6.2 kW
6.2 kW
SCOP
4.55
3.47
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.46 kW
5.53 kW
COP Tj = -7°C
2.58
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.04 kW
3.50 kW
COP Tj = +2°C
4.62
3.37
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.28 kW
2.21 kW
COP Tj = +7°C
6.05
4.79
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.94 kW
1.88 kW
COP Tj = 12°C
7.21
5.74
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.46 kW
5.53 kW
COP Tj = Tbiv
2.58
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.44 kW
5.08 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.58
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
31 W
31 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.76 kW
1.12 kW
Annual energy consumption Qhe
2814 kWh
3686 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
207 %
161 %
Prated
7.1 kW
5.7 kW
SCOP
5.25
4.09
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.08 kW
5.72 kW
COP Tj = +2°C
2.83
2.18
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.67 kW
COP Tj = +7°C
4.23
3.41
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
1.88 kW
1.83 kW
COP Tj = 12°C
7.37
5.59
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
7.08 kW
5.72 kW
COP Tj = Tbiv
2.83
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.08 kW
5.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1807 kWh
1860 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
117 %
Prated
7.3 kW
6.6 kW
SCOP
4.09
3.01
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.07 kW
3.72 kW
COP Tj = -7°C
3.3
2.39
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.38 kW
COP Tj = +2°C
5.2
3.67
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.86 kW
1.84 kW
COP Tj = +7°C
6.24
4.72
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
7
5.53
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.01 kW
5.37 kW
COP Tj = Tbiv
2.38
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.03 kW
3.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.03
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.27 kW
3.32 kW
Annual energy consumption Qhe
4397 kWh
5410 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.01
5.37
COP Tj = -15°C (if TOL<-20°C)
2.38
1.96
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
138 %
Prated
6.6 kW
6.6 kW
SCOP
4.58
3.52
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.42 kW
5.94 kW
COP Tj = -7°C
2.61
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.51 kW
3.53 kW
COP Tj = +2°C
4.68
3.49
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.20 kW
2.45 kW
COP Tj = +7°C
6.09
4.68
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.85 kW
1.80 kW
COP Tj = 12°C
7.23
5.75
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.42 kW
5.94 kW
COP Tj = Tbiv
2.61
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.86 kW
5.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.23
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
1.39 kW
Annual energy consumption Qhe
2975 kWh
3878 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.83 kW
3.18 kW
El input
0.59 kW
1.18 kW
COP
4.81
2.7
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
158 %
Prated
7.1 kW
5.7 kW
SCOP
5.21
4.04
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.08 kW
5.68 kW
COP Tj = +2°C
2.81
2.16
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.64 kW
COP Tj = +7°C
4.2
3.38
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
1.88 kW
1.82 kW
COP Tj = 12°C
7.31
5.48
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
7.08 kW
5.68 kW
COP Tj = Tbiv
2.81
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.08 kW
5.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
2.16
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1820 kWh
1887 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
116 %
Prated
7.3 kW
6.6 kW
SCOP
4.07
2.97
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.06 kW
3.69 kW
COP Tj = -7°C
3.29
2.36
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.37 kW
COP Tj = +2°C
5.17
3.62
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.86 kW
1.83 kW
COP Tj = +7°C
6.21
4.64
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.83 kW
1.78 kW
COP Tj = 12°C
6.95
5.42
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6 kW
5.33 kW
COP Tj = Tbiv
2.37
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.02
1.56
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.29 kW
3.37 kW
Annual energy consumption Qhe
4418 kWh
5475 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6
5.33
COP Tj = -15°C (if TOL<-20°C)
2.37
1.95
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
136 %
Prated
6.6 kW
6.6 kW
SCOP
4.56
3.48
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.41 kW
5.90 kW
COP Tj = -7°C
2.60
2.07
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.50 kW
3.50 kW
COP Tj = +2°C
4.66
3.46
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.20 kW
2.44 kW
COP Tj = +7°C
6.05
4.62
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.85 kW
1.79 kW
COP Tj = 12°C
7.17
5.64
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.41 kW
5.90 kW
COP Tj = Tbiv
2.60
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.85 kW
5.16 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
1.44 kW
Annual energy consumption Qhe
2990 kWh
3917 kWh
Domestic Hot Water (DHW)
Warmer Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
106 %
COP
2.49
Heating up time
2:39 h:min
Standby power input
86.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Colder Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
75 %
COP
1.75
Heating up time
3:11 h:min
Standby power input
131.0 W
Reference hot water temperature
51.9 °C
Mixed water at 40°C
234 l
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
92 %
COP
2.17
Heating up time
2:39 h:min
Standby power input
92.0 W
Reference hot water temperature
52.6 °C
Mixed water at 40°C
235 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.2 kW
El input
0.59 kW
1.18 kW
COP
4.82
2.72
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
206 %
159 %
Prated
7.1 kW
5.7 kW
SCOP
5.22
4.05
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.09 kW
5.7 kW
COP Tj = +2°C
2.82
2.17
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.66 kW
COP Tj = +7°C
4.2
3.39
Cdh Tj = +7 °C
0.99
0.99
Pdh Tj = 12°C
1.88 kW
1.83 kW
COP Tj = 12°C
7.32
5.5
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
7.09 kW
5.7 kW
COP Tj = Tbiv
2.82
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.09 kW
5.7 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
2.17
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1818 kWh
1880 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
117 %
Prated
7.3 kW
6.6 kW
SCOP
4.09
2.99
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.06 kW
3.7 kW
COP Tj = -7°C
3.29
2.37
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.38 kW
COP Tj = +2°C
5.18
3.63
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
1.86 kW
1.59 kW
COP Tj = +7°C
6.21
4.81
Cdh Tj = +7 °C
0.95
0.95
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
6.99
5.43
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
6.03 kW
5.35 kW
COP Tj = Tbiv
2.41
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.02 kW
3.26 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.03
1.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.28 kW
3.34 kW
Annual energy consumption Qhe
4400 kWh
5436 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.03
5.35
COP Tj = -15°C (if TOL<-20°C)
2.41
1.95
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
37 dB(A)
37 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
136 %
Prated
6.6 kW
6.6 kW
SCOP
4.56
3.49
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.42 kW
5.98 kW
COP Tj = -7°C
2.60
2.05
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.51 kW
3.51 kW
COP Tj = +2°C
4.67
3.47
Cdh Tj = +2 °C
0.98
0.99
Pdh Tj = +7°C
2.20 kW
2.45 kW
COP Tj = +7°C
6.06
4.63
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
1.85 kW
1.80 kW
COP Tj = 12°C
7.14
5.66
Cdh Tj = +12 °C
0.94
0.95
Pdh Tj = Tbiv
5.42 kW
5.98 kW
COP Tj = Tbiv
2.60
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.86 kW
5.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.22
1.82
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
15 W
15 W
PTO
15 W
15 W
PSB
15 W
15 W
PCK
32 W
32 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
1.41 kW
Annual energy consumption Qhe
2987 kWh
3912 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
2.02 kW
El input
0.59 kW
0.79 kW
COP
4.85
2.55
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
133 %
Prated
4.3 kW
3.8 kW
SCOP
4.79
3.36
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.31 kW
3.92 kW
COP Tj = +2°C
3.21
2.12
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.64 kW
2.41 kW
COP Tj = +7°C
4.95
3.09
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.82 kW
1.79 kW
COP Tj = 12°C
6.72
5.01
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
4.31 kW
3.92 kW
COP Tj = Tbiv
3.21
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.31 kW
3.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.21
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1199 kWh
1511 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
107 %
Prated
3.8 kW
3.2 kW
SCOP
3.82
2.69
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.26 kW
1.87 kW
COP Tj = -7°C
3.42
2.27
Cdh Tj = -7 °C
0.97
0.98
Pdh Tj = +2°C
1.86 kW
1.78 kW
COP Tj = +2°C
4.8
3.32
Cdh Tj = +2 °C
0.95
0.97
Pdh Tj = +7°C
1.61 kW
1.58 kW
COP Tj = +7°C
5.76
4.29
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.63
5.25
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
3.12 kW
2.64 kW
COP Tj = Tbiv
2.51
1.8
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.22 kW
2.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.84
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.58 kW
1.13 kW
Annual energy consumption Qhe
2451 kWh
2932 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.12
2.64
COP Tj = -15°C (if TOL<-20°C)
2.51
1.8
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
173 %
126 %
Prated
4.4 kW
4 kW
SCOP
4.34
3.18
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.91 kW
3.55 kW
COP Tj = -7°C
2.89
2.12
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.26 kW
COP Tj = +2°C
4.48
3.24
Cdh Tj = +2 °C
0.97
0.97
Pdh Tj = +7°C
1.73 kW
1.55 kW
COP Tj = +7°C
6.17
4.37
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.97 kW
1.83 kW
COP Tj = 12°C
7.43
5.41
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
3.91 kW
3.55 kW
COP Tj = Tbiv
2.89
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.63 kW
3.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.77 kW
0.85 kW
Annual energy consumption Qhe
2093 kWh
2599 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
150 %
Prated
6.4 kW
5.9 kW
SCOP
5.16
3.78
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.43 kW
5.93 kW
COP Tj = +2°C
2.91
2.15
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.14 kW
3.84 kW
COP Tj = +7°C
4.79
3.51
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
1.95 kW
1.78 kW
COP Tj = 12°C
7.38
5.15
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
6.43 kW
5.93 kW
COP Tj = Tbiv
2.91
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.43 kW
5.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1656 kWh
2087 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
124 %
Prated
5.4 kW
5.3 kW
SCOP
4.16
3.13
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.45 kW
3.18 kW
COP Tj = -7°C
3.44
2.64
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.1 kW
COP Tj = +2°C
5.47
3.8
Cdh Tj = +2 °C
0.95
0.97
Pdh Tj = +7°C
1.74 kW
1.71 kW
COP Tj = +7°C
6.25
5.18
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.92 kW
1.9 kW
COP Tj = 12°C
6.87
5.92
Cdh Tj = +12 °C
0.94
0.94
Pdh Tj = Tbiv
4.62 kW
4.3 kW
COP Tj = Tbiv
2.41
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.39 kW
1.65 kW
Annual energy consumption Qhe
3199 kWh
4180 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.62
4.3
COP Tj = -15°C (if TOL<-20°C)
2.41
1.91
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
135 %
Prated
6.2 kW
6.2 kW
SCOP
4.41
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.47 kW
5.57 kW
COP Tj = -7°C
2.59
2.11
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.05 kW
3.52 kW
COP Tj = +2°C
4.64
3.39
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.28 kW
2.21 kW
COP Tj = +7°C
6.07
4.84
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.95 kW
1.88 kW
COP Tj = 12°C
7.26
5.83
Cdh Tj = +12 °C
0.93
0.94
Pdh Tj = Tbiv
5.47 kW
5.57 kW
COP Tj = Tbiv
2.59
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.45 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
1.10 kW
Annual energy consumption Qhe
2906 kWh
3758 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
153 %
Prated
7.1 kW
5.7 kW
SCOP
4.93
3.85
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.08 kW
5.72 kW
COP Tj = +2°C
2.83
2.18
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.67 kW
COP Tj = +7°C
4.23
3.41
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
1.88 kW
1.83 kW
COP Tj = 12°C
7.37
5.59
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
7.08 kW
5.72 kW
COP Tj = Tbiv
2.83
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.08 kW
5.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1926 kWh
1979 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
118 %
Prated
7.3 kW
6.6 kW
SCOP
4.03
2.97
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.07 kW
3.72 kW
COP Tj = -7°C
3.3
2.39
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.38 kW
COP Tj = +2°C
5.2
3.67
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.86 kW
1.84 kW
COP Tj = +7°C
6.24
4.72
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
7
5.53
Cdh Tj = +12 °C
0.93
0.94
Pdh Tj = Tbiv
6.01 kW
5.37 kW
COP Tj = Tbiv
2.38
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.03 kW
3.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.83
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.27 kW
3.32 kW
Annual energy consumption Qhe
4460 kWh
5474 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.01
5.37
COP Tj = -15°C (if TOL<-20°C)
2.38
1.96
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
31 dB(A)
31 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
136 %
Prated
6.6 kW
6.6 kW
SCOP
4.43
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.42 kW
5.94 kW
COP Tj = -7°C
2.61
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.51 kW
3.53 kW
COP Tj = +2°C
4.68
3.49
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.20 kW
2.45 kW
COP Tj = +7°C
6.09
4.68
Cdh Tj = +7 °C
0.95
0.97
Pdh Tj = 12°C
1.85 kW
1.80 kW
COP Tj = 12°C
7.23
5.75
Cdh Tj = +12 °C
0.93
0.94
Pdh Tj = Tbiv
5.42 kW
5.94 kW
COP Tj = Tbiv
2.61
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.86 kW
5.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.23
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
1.39 kW
Annual energy consumption Qhe
3079 kWh
3981 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
2.02 kW
El input
0.59 kW
0.79 kW
COP
4.85
2.55
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
191 %
133 %
Prated
4.3 kW
3.8 kW
SCOP
4.79
3.36
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
4.31 kW
3.92 kW
COP Tj = +2°C
3.21
2.12
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
2.64 kW
2.41 kW
COP Tj = +7°C
4.95
3.09
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
1.82 kW
1.79 kW
COP Tj = 12°C
6.72
5.01
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
4.31 kW
3.92 kW
COP Tj = Tbiv
3.21
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.31 kW
3.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.21
2.12
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1199 kWh
1511 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
152 %
107 %
Prated
3.8 kW
3.2 kW
SCOP
3.82
2.69
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
2.26 kW
1.87 kW
COP Tj = -7°C
3.42
2.27
Cdh Tj = -7 °C
0.97
0.98
Pdh Tj = +2°C
1.86 kW
1.78 kW
COP Tj = +2°C
4.8
3.32
Cdh Tj = +2 °C
0.95
0.97
Pdh Tj = +7°C
1.61 kW
1.58 kW
COP Tj = +7°C
5.76
4.29
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.81 kW
1.78 kW
COP Tj = 12°C
6.63
5.25
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
3.12 kW
2.64 kW
COP Tj = Tbiv
2.51
1.8
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.22 kW
2.07 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.84
1.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.58 kW
1.13 kW
Annual energy consumption Qhe
2451 kWh
2932 kWh
Pdh Tj = -15°C (if TOL<-20°C)
3.12
2.64
COP Tj = -15°C (if TOL<-20°C)
2.51
1.8
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
40 dB(A)
40 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
173 %
126 %
Prated
4.4 kW
4 kW
SCOP
4.34
3.18
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.91 kW
3.55 kW
COP Tj = -7°C
2.89
2.12
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.48 kW
2.26 kW
COP Tj = +2°C
4.48
3.24
Cdh Tj = +2 °C
0.97
0.97
Pdh Tj = +7°C
1.73 kW
1.55 kW
COP Tj = +7°C
6.17
4.37
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.97 kW
1.83 kW
COP Tj = 12°C
7.43
5.41
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
3.91 kW
3.55 kW
COP Tj = Tbiv
2.89
3.55
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.63 kW
3.15 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.77 kW
0.85 kW
Annual energy consumption Qhe
2093 kWh
2599 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
205 %
150 %
Prated
6.4 kW
5.9 kW
SCOP
5.16
3.78
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.43 kW
5.93 kW
COP Tj = +2°C
2.91
2.15
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.14 kW
3.84 kW
COP Tj = +7°C
4.79
3.51
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
1.95 kW
1.78 kW
COP Tj = 12°C
7.38
5.15
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
6.43 kW
5.93 kW
COP Tj = Tbiv
2.91
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.43 kW
5.93 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.91
2.15
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1656 kWh
2087 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165 %
124 %
Prated
5.4 kW
5.3 kW
SCOP
4.16
3.13
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.45 kW
3.18 kW
COP Tj = -7°C
3.44
2.64
Cdh Tj = -7 °C
0.98
0.99
Pdh Tj = +2°C
2.07 kW
2.1 kW
COP Tj = +2°C
5.47
3.8
Cdh Tj = +2 °C
0.95
0.97
Pdh Tj = +7°C
1.74 kW
1.71 kW
COP Tj = +7°C
6.25
5.18
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.92 kW
1.9 kW
COP Tj = 12°C
6.87
5.92
Cdh Tj = +12 °C
0.94
0.94
Pdh Tj = Tbiv
4.62 kW
4.3 kW
COP Tj = Tbiv
2.41
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.01 kW
3.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.89
1.58
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.39 kW
1.65 kW
Annual energy consumption Qhe
3199 kWh
4180 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.62
4.3
COP Tj = -15°C (if TOL<-20°C)
2.41
1.91
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
135 %
Prated
6.2 kW
6.2 kW
SCOP
4.41
3.41
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.47 kW
5.57 kW
COP Tj = -7°C
2.59
2.11
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.05 kW
3.52 kW
COP Tj = +2°C
4.64
3.39
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.28 kW
2.21 kW
COP Tj = +7°C
6.07
4.84
Cdh Tj = +7 °C
0.95
0.96
Pdh Tj = 12°C
1.95 kW
1.88 kW
COP Tj = 12°C
7.26
5.83
Cdh Tj = +12 °C
0.93
0.94
Pdh Tj = Tbiv
5.47 kW
5.57 kW
COP Tj = Tbiv
2.59
2.11
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.45 kW
5.10 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.89
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.75 kW
1.10 kW
Annual energy consumption Qhe
2906 kWh
3758 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
2.84 kW
3.23 kW
El input
0.59 kW
1.18 kW
COP
4.85
2.74
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
196 %
153 %
Prated
7.1 kW
5.7 kW
SCOP
4.93
3.85
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
7.08 kW
5.72 kW
COP Tj = +2°C
2.83
2.18
Cdh Tj = +2 °C
0.99
0.99
Pdh Tj = +7°C
4.25 kW
3.67 kW
COP Tj = +7°C
4.23
3.41
Cdh Tj = +7 °C
0.98
0.98
Pdh Tj = 12°C
1.88 kW
1.83 kW
COP Tj = 12°C
7.37
5.59
Cdh Tj = +12 °C
0.93
0.95
Pdh Tj = Tbiv
7.08 kW
5.72 kW
COP Tj = Tbiv
2.83
2.18
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.08 kW
5.72 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.83
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0 kW
0 kW
Annual energy consumption Qhe
1926 kWh
1979 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
118 %
Prated
7.3 kW
6.6 kW
SCOP
4.03
2.97
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.07 kW
3.72 kW
COP Tj = -7°C
3.3
2.39
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
2.52 kW
2.38 kW
COP Tj = +2°C
5.2
3.67
Cdh Tj = +2 °C
0.96
0.97
Pdh Tj = +7°C
1.86 kW
1.84 kW
COP Tj = +7°C
6.24
4.72
Cdh Tj = +7 °C
0.94
0.95
Pdh Tj = 12°C
1.84 kW
1.79 kW
COP Tj = 12°C
7
5.53
Cdh Tj = +12 °C
0.93
0.94
Pdh Tj = Tbiv
6.01 kW
5.37 kW
COP Tj = Tbiv
2.38
1.96
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.03 kW
3.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.83
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.27 kW
3.32 kW
Annual energy consumption Qhe
4460 kWh
5474 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.01
5.37
COP Tj = -15°C (if TOL<-20°C)
2.38
1.96
Cdh Tj = -15 °C
0.99
0.99
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
35 dB(A)
35 dB(A)
Sound power level outdoor
42 dB(A)
42 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
176 %
136 %
Prated
6.6 kW
6.6 kW
SCOP
4.43
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.42 kW
5.94 kW
COP Tj = -7°C
2.61
2.09
Cdh Tj = -7 °C
0.99
0.99
Pdh Tj = +2°C
3.51 kW
3.53 kW
COP Tj = +2°C
4.68
3.49
Cdh Tj = +2 °C
0.98
0.98
Pdh Tj = +7°C
2.20 kW
2.45 kW
COP Tj = +7°C
6.09
4.68
Cdh Tj = +7 °C
0.95
0.97
Pdh Tj = 12°C
1.85 kW
1.80 kW
COP Tj = 12°C
7.23
5.75
Cdh Tj = +12 °C
0.93
0.94
Pdh Tj = Tbiv
5.42 kW
5.94 kW
COP Tj = Tbiv
2.61
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.86 kW
5.21 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.23
1.83
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.99
0.99
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
18 W
18 W
PSB
18 W
18 W
PCK
22 W
22 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.74 kW
1.39 kW
Annual energy consumption Qhe
3079 kWh
3981 kWh