17,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
78.60 kW
75.70 kW
El input
18.20 kW
29.80 kW
COP
4.31
2.54
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
78 dB(A)
78 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
170 %
125 %
Prated
53.40 kW
58.02 kW
SCOP
4.33
3.20
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
47.21 kW
47.66 kW
COP Tj = -7°C
2.73
1.96
Cdh Tj = -7 °C
0.970
0.970
Pdh Tj = +2°C
30.76 kW
29.59 kW
COP Tj = +2°C
4.34
3.12
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
35.04 kW
39.10 kW
COP Tj = +7°C
5.60
4.42
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
40.87 kW
33.21 kW
COP Tj = 12°C
7.28
6.07
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
47.21 kW
49.09 kW
COP Tj = Tbiv
2.73
2.02
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
44.78 kW
45.04 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.42
1.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.970
WTOL
35 °C
55 °C
Poff
110 W
110 W
PTO
200 W
200 W
PSB
110 W
110 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
8.59 kW
12.98 kW
Annual energy consumption Qhe
25443 kWh
37519 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
87.50 kW
86.10 kW
El input
22.10 kW
35.20 kW
COP
3.95
2.44
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
81 dB(A)
81 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
169 %
125 %
Prated
58.90 kW
62.63 kW
SCOP
4.29
3.19
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
52.10 kW
51.45 kW
COP Tj = -7°C
2.67
1.94
Cdh Tj = -7 °C
0.970
0.970
Pdh Tj = +2°C
30.80 kW
31.11 kW
COP Tj = +2°C
4.30
3.09
Cdh Tj = +2 °C
0.970
0.970
Pdh Tj = +7°C
35.10 kW
40.31 kW
COP Tj = +7°C
5.53
4.42
Cdh Tj = +7 °C
0.970
0.970
Pdh Tj = 12°C
40.91 kW
34.24 kW
COP Tj = 12°C
7.19
6.43
Cdh Tj = +12 °C
0.970
0.970
Pdh Tj = Tbiv
52.10 kW
53.00 kW
COP Tj = Tbiv
2.67
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
50.10 kW
48.62 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.50
1.57
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.970
WTOL
35 °C
55 °C
Poff
110 W
110 W
PTO
200 W
200 W
PSB
110 W
110 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
8.80 kW
14.01 kW
Annual energy consumption Qhe
28335 kWh
40595 kWh
Heating
EN 14511-2
Heat output
84.80 kW
El input
21.20 kW
COP
4.01
Average Climate
EN 12102-1
Sound power level outdoor
80 dB(A)
EN 14825
ηs
162 %
Prated
55.80 kW
SCOP
4.12
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
49.33 kW
COP Tj = -7°C
2.70
Cdh Tj = -7 °C
0.950
Pdh Tj = +2°C
31.45 kW
COP Tj = +2°C
4.15
Cdh Tj = +2 °C
0.950
Pdh Tj = +7°C
35.74 kW
COP Tj = +7°C
5.34
Cdh Tj = +7 °C
0.950
Pdh Tj = 12°C
41.42 kW
COP Tj = 12°C
6.68
Cdh Tj = +12 °C
0.950
Pdh Tj = Tbiv
49.33 kW
COP Tj = Tbiv
2.70
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
46.28 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.950
WTOL
35 °C
Poff
110 W
PTO
200 W
PSB
110 W
PCK
10 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
9.48 kW
Annual energy consumption Qhe
27961 kWh
Heating
EN 14511-2
Heat output
94.20 kW
El input
25.70 kW
COP
3.67
Average Climate
EN 12102-1
Sound power level outdoor
83 dB(A)
EN 14825
ηs
160 %
Prated
62.80 kW
SCOP
4.08
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
55.56 kW
COP Tj = -7°C
2.62
Cdh Tj = -7 °C
0.950
Pdh Tj = +2°C
33.51 kW
COP Tj = +2°C
4.10
Cdh Tj = +2 °C
0.950
Pdh Tj = +7°C
35.91 kW
COP Tj = +7°C
5.30
Cdh Tj = +7 °C
0.950
Pdh Tj = 12°C
42.87 kW
COP Tj = 12°C
6.60
Cdh Tj = +12 °C
0.950
Pdh Tj = Tbiv
55.56 kW
COP Tj = Tbiv
2.62
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
50.14 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.48
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.950
WTOL
35 °C
Poff
110 W
PTO
200 W
PSB
110 W
PCK
10 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
12.67 kW
Annual energy consumption Qhe
31806 kWh
Heating
EN 14511-2
Heat output
101.00 kW
El input
27.70 kW
COP
3.64
Average Climate
EN 12102-1
Sound power level outdoor
83 dB(A)
EN 14825
ηs
162 %
Prated
67.00 kW
SCOP
4.13
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
59.24 kW
COP Tj = -7°C
2.60
Cdh Tj = -7 °C
0.970
Pdh Tj = +2°C
36.53 kW
COP Tj = +2°C
4.08
Cdh Tj = +2 °C
0.970
Pdh Tj = +7°C
36.00 kW
COP Tj = +7°C
5.40
Cdh Tj = +7 °C
0.970
Pdh Tj = 12°C
42.95 kW
COP Tj = 12°C
6.76
Cdh Tj = +12 °C
0.970
Pdh Tj = Tbiv
59.24 kW
COP Tj = Tbiv
2.60
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
55.44 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
WTOL
35 °C
Poff
110 W
PTO
200 W
PSB
110 W
PCK
10 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
11.53 kW
Annual energy consumption Qhe
33528 kWh