14,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
51.50 kW
46.50 kW
El input
11.30 kW
17.20 kW
COP
4.54
2.71
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
75 dB(A)
75 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
126 %
Prated
34.80 kW
33.20 kW
SCOP
4.46
3.24
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
30.79 kW
26.60 kW
COP Tj = -7°C
2.81
1.87
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
21.36 kW
18.78 kW
COP Tj = +2°C
4.52
3.26
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
25.20 kW
23.47 kW
COP Tj = +7°C
5.72
4.49
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
29.84 kW
28.35 kW
COP Tj = 12°C
7.63
6.23
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
30.79 kW
28.13 kW
COP Tj = Tbiv
2.81
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
28.65 kW
14.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.10
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
35 °C
55 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
6.16 kW
19.24 kW
Annual energy consumption Qhe
16118 kWh
21227 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
55.50 kW
51.90 kW
El input
12.80 kW
19.40 kW
COP
4.33
2.68
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
76 dB(A)
76 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
175 %
125 %
Prated
38.60 kW
37.27 kW
SCOP
4.46
3.21
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
34.16 kW
30.48 kW
COP Tj = -7°C
2.79
1.87
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
22.74 kW
20.42 kW
COP Tj = +2°C
4.45
3.17
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
25.15 kW
23.63 kW
COP Tj = +7°C
5.75
4.53
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
29.80 kW
28.56 kW
COP Tj = 12°C
7.72
6.50
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
34.16 kW
31.53 kW
COP Tj = Tbiv
2.79
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.20 kW
15.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
1.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
35 °C
55 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
5.40 kW
22.27 kW
Annual energy consumption Qhe
17891 kWh
24016 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
64.10 kW
56.70 kW
El input
15.50 kW
21.00 kW
COP
4.15
2.70
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
78 dB(A)
78 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
173 %
125 %
Prated
43.00 kW
40.32 kW
SCOP
4.41
3.19
Tbiv
-7 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
38.01 kW
33.01 kW
COP Tj = -7°C
2.68
1.86
Cdh Tj = -7 °C
0.970
0.980
Pdh Tj = +2°C
22.78 kW
21.39 kW
COP Tj = +2°C
4.44
3.12
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
25.19 kW
23.63 kW
COP Tj = +7°C
5.66
4.58
Cdh Tj = +7 °C
0.970
0.980
Pdh Tj = 12°C
29.84 kW
28.56 kW
COP Tj = 12°C
7.60
6.63
Cdh Tj = +12 °C
0.970
0.980
Pdh Tj = Tbiv
38.01 kW
34.12 kW
COP Tj = Tbiv
2.68
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
35.92 kW
16.00 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.20
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.970
0.980
WTOL
35 °C
55 °C
Poff
90 W
90 W
PTO
150 W
150 W
PSB
90 W
90 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
7.04 kW
24.32 kW
Annual energy consumption Qhe
20144 kWh
26137 kWh
Heating
EN 14511-2
Heat output
54.40 kW
El input
12.70 kW
COP
4.30
Average Climate
EN 12102-1
Sound power level outdoor
77 dB(A)
EN 14825
ηs
166 %
Prated
36.30 kW
SCOP
4.22
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
32.11 kW
COP Tj = -7°C
2.69
Cdh Tj = -7 °C
0.950
Pdh Tj = +2°C
20.72 kW
COP Tj = +2°C
4.25
Cdh Tj = +2 °C
0.950
Pdh Tj = +7°C
24.84 kW
COP Tj = +7°C
5.55
Cdh Tj = +7 °C
0.950
Pdh Tj = 12°C
29.72 kW
COP Tj = 12°C
7.27
Cdh Tj = +12 °C
0.950
Pdh Tj = Tbiv
32.11 kW
COP Tj = Tbiv
2.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
28.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.950
WTOL
35 °C
Poff
90 W
PTO
150 W
PSB
90 W
PCK
10 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
7.65 kW
Annual energy consumption Qhe
17769 kWh
Heating
EN 14511-2
Heat output
58.70 kW
El input
14.40 kW
COP
4.06
Average Climate
EN 12102-1
Sound power level outdoor
78 dB(A)
EN 14825
ηs
166 %
Prated
40.40 kW
SCOP
4.19
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
35.74 kW
COP Tj = -7°C
2.68
Cdh Tj = -7 °C
0.950
Pdh Tj = +2°C
22.06 kW
COP Tj = +2°C
4.21
Cdh Tj = +2 °C
0.950
Pdh Tj = +7°C
24.90 kW
COP Tj = +7°C
5.43
Cdh Tj = +7 °C
0.950
Pdh Tj = 12°C
29.54 kW
COP Tj = 12°C
7.04
Cdh Tj = +12 °C
0.950
Pdh Tj = Tbiv
35.74 kW
COP Tj = Tbiv
2.68
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.950
WTOL
35 °C
Poff
90 W
PTO
150 W
PSB
90 W
PCK
10 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
7.18 kW
Annual energy consumption Qhe
19931 kWh
Heating
EN 14511-2
Heat output
67.10 kW
El input
16.90 kW
COP
3.98
Average Climate
EN 12102-1
Sound power level outdoor
80 dB(A)
EN 14825
ηs
164 %
Prated
45.00 kW
SCOP
3.19
Tbiv
-7 °C
TOL
-10 °C
Pdh Tj = -7°C
39.83 kW
COP Tj = -7°C
2.62
Cdh Tj = -7 °C
0.950
Pdh Tj = +2°C
23.48 kW
COP Tj = +2°C
4.21
Cdh Tj = +2 °C
0.950
Pdh Tj = +7°C
24.94 kW
COP Tj = +7°C
5.39
Cdh Tj = +7 °C
0.950
Pdh Tj = 12°C
29.51 kW
COP Tj = 12°C
6.94
Cdh Tj = +12 °C
0.950
Pdh Tj = Tbiv
39.83 kW
COP Tj = Tbiv
2.62
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
35.92 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.950
WTOL
35 °C
Poff
90 W
PTO
150 W
PSB
90 W
PCK
10 W
Supplementary Heater: Type of energy input
n/a
Supplementary Heater: PSUP
9.11 kW
Annual energy consumption Qhe
22286 kWh