Certificate holders

Subtype

Thermia Mega Eco L

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-C700190 / Issue 1
Certification Body
RISE CERT
Subtype title
Thermia Mega Eco L
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R454B
Mass of Refrigerant

5,900 kg

Certification Date
11.12.2023
Testing basis
EN 14511:2018, EN 14825:2016, EN 12102:2017.
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Thermia Mega Eco L 400V
Configure model
Model name
Thermia Mega Eco L 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

35.44 kW

33.49 kW

El input

7.51 kW

10.82 kW

COP

4.72

3.10

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

207 %

165 %

Prated

58.48 kW

56.10 kW

SCOP

5.37

4.33

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

58.48 kW

56.10 kW

COP Tj = +2°C

3.96

2.85

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

37.59 kW

36.06 kW

COP Tj = +7°C

5.00

3.77

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

16.71 kW

16.03 kW

COP Tj = 12°C

6.00

5.23

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

58.48 kW

56.10 kW

COP Tj = Tbiv

3.96

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

58.48 kW

56.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.96

2.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

14551 kWh

17310 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

213 %

170 %

Prated

58.48 kW

56.10 kW

SCOP

5.54

4.46

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

35.40 kW

33.95 kW

COP Tj = -7°C

5.25

3.99

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

21.55 kW

20.67 kW

COP Tj = +2°C

5.95

4.95

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

15.95 kW

15.75 kW

COP Tj = +7°C

6.01

5.35

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

15.91 kW

15.76 kW

COP Tj = 12°C

5.78

5.39

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

58.48 kW

56.10 kW

COP Tj = Tbiv

3.96

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

58.48 kW

56.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.96

2.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

26039 kWh

30994 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

44 dB(A)

44 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

205 %

163 %

Prated

58.48 kW

56.10 kW

SCOP

5.32

4.27

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

51.73 kW

49.60 kW

COP Tj = -7°C

4.28

3.09

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

31.49 kW

30.21 kW

COP Tj = +2°C

5.33

4.25

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

20.24 kW

19.42 kW

COP Tj = +7°C

5.98

5.05

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

15.94 kW

15.72 kW

COP Tj = 12°C

5.92

5.29

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

58.48 kW

56.10 kW

COP Tj = Tbiv

3.96

2.85

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

58.48 kW

56.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.96

2.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

22720 kWh

27150 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

47.43 kW

44.05 kW

El input

7.73 kW

11.14 kW

COP

6.13

3.95

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

304 %

215 %

Prated

52.53 kW

54.94 kW

SCOP

7.79

5.57

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

52.53 kW

54.94 kW

COP Tj = +2°C

5.92

3.69

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

33.77 kW

35.32 kW

COP Tj = +7°C

7.49

4.97

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

20.03 kW

19.99 kW

COP Tj = 12°C

8.48

6.59

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

52.53 kW

54.94 kW

COP Tj = Tbiv

5.92

3.69

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

52.53 kW

54.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.92

3.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

9008 kWh

13182 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

314 %

223 %

Prated

52.53 kW

54.94 kW

SCOP

8.06

5.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

31.79 kW

33.25 kW

COP Tj = -7°C

7.78

5.27

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

19.35 kW

20.24 kW

COP Tj = +2°C

8.56

6.33

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

20.04 kW

20.02 kW

COP Tj = +7°C

8.59

6.79

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

20.02 kW

20.05 kW

COP Tj = 12°C

8.36

7.05

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

52.53 kW

54.94 kW

COP Tj = Tbiv

5.92

3.69

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

52.53 kW

54.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.92

3.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

16072 kWh

23456 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

303 %

215 %

Prated

52.53 kW

54.94 kW

SCOP

7.77

5.58

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

46.47 kW

48.60 kW

COP Tj = -7°C

6.44

4.08

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

28.29 kW

29.58 kW

COP Tj = +2°C

7.83

5.59

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

20.03 kW

19.02 kW

COP Tj = +7°C

8.56

6.53

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

20.03 kW

20.02 kW

COP Tj = 12°C

8.56

6.83

Cdh Tj = +12 °C

1.000

1.000

Pdh Tj = Tbiv

52.53 kW

54.94 kW

COP Tj = Tbiv

5.92

3.69

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

52.53 kW

54.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.92

3.69

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

13969 kWh

20358 kWh