2,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.00 kW
13.00 kW
El input
2.92 kW
4.26 kW
COP
4.80
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
11.90 kW
11.70 kW
SCOP
4.61
3.29
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.50 kW
10.33 kW
COP Tj = -7°C
2.97
2.22
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.39 kW
6.35 kW
COP Tj = +2°C
4.40
3.04
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.21 kW
4.31 kW
COP Tj = +7°C
6.21
4.36
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.90 kW
3.76 kW
COP Tj = 12°C
7.42
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.50 kW
10.33 kW
COP Tj = Tbiv
2.97
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.82 kW
11.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.91
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
5 W
5 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.08 kW
0.20 kW
Annual energy consumption Qhe
5320 kWh
7340 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
124 %
COP
3.00
Heating up time
1:44 h:min
Standby power input
40.1 W
Reference hot water temperature
48.7 °C
Mixed water at 40°C
260 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.00 kW
13.00 kW
El input
2.92 kW
4.26 kW
COP
4.80
3.05
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
66 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
128 %
Prated
11.90 kW
11.70 kW
SCOP
4.61
3.29
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.50 kW
10.33 kW
COP Tj = -7°C
2.97
2.22
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.39 kW
6.35 kW
COP Tj = +2°C
4.40
3.04
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.21 kW
4.31 kW
COP Tj = +7°C
6.21
4.36
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.90 kW
3.76 kW
COP Tj = 12°C
7.42
6.25
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.50 kW
10.33 kW
COP Tj = Tbiv
2.97
2.22
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.82 kW
11.50 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.65
1.91
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
5 W
5 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.08 kW
0.20 kW
Annual energy consumption Qhe
5320 kWh
7340 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.80
Heating up time
1:45 h:min
Standby power input
53.5 W
Reference hot water temperature
48.7 °C
Mixed water at 40°C
260 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.00 kW
El input
3.48 kW
5.08 kW
COP
4.60
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
128 %
Prated
13.00 kW
12.50 kW
SCOP
4.49
3.28
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.53 kW
11.10 kW
COP Tj = -7°C
2.86
2.24
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.98 kW
6.57 kW
COP Tj = +2°C
4.23
3.06
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.67 kW
4.30 kW
COP Tj = +7°C
6.21
4.33
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.90 kW
3.76 kW
COP Tj = 12°C
7.45
5.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.53 kW
11.10 kW
COP Tj = Tbiv
2.86
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.75 kW
12.03 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.64
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
5 W
5 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.25 kW
0.47 kW
Annual energy consumption Qhe
5999 kWh
7900 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
124 %
COP
3.00
Heating up time
1:44 h:min
Standby power input
40.1 W
Reference hot water temperature
48.7 °C
Mixed water at 40°C
260 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.00 kW
El input
3.48 kW
5.08 kW
COP
4.60
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
67 dB(A)
67 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
128 %
Prated
13.00 kW
12.50 kW
SCOP
4.49
3.28
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.53 kW
11.10 kW
COP Tj = -7°C
2.86
2.24
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.98 kW
6.57 kW
COP Tj = +2°C
4.23
3.06
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.67 kW
4.30 kW
COP Tj = +7°C
6.21
4.33
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
3.90 kW
3.76 kW
COP Tj = 12°C
7.45
5.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.53 kW
11.10 kW
COP Tj = Tbiv
2.86
2.24
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.75 kW
12.03 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.64
1.88
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
65 °C
65 °C
Poff
5 W
5 W
PTO
9 W
9 W
PSB
5 W
5 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.25 kW
0.47 kW
Annual energy consumption Qhe
5999 kWh
7900 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
117 %
COP
2.80
Heating up time
1:45 h:min
Standby power input
53.5 W
Reference hot water temperature
48.7 °C
Mixed water at 40°C
260 l