Certificate holders

Subtype

Acond Grandis-R

Certificate Holder
Acond a.s.
Štěrboholská 1434/102a
102 00 Hostivař, Praha
Czech Republic
Registration number
037-0103-22 / rev. 1
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Acond Grandis-R
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,320 kg

Certification Date
07.12.2022
Testing basis
HP Keymark scheme rules rev. no. 10
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

Acond Grandis-R
Configure model
Model name
Acond Grandis-R
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.98 kW

6.94 kW

El input

1.26 kW

2.05 kW

COP

5.52

3.38

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

220 %

165 %

Prated

10.19 kW

9.97 kW

SCOP

5.58

4.21

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.97 kW

8.80 kW

COP Tj = -7°C

3.57

2.67

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.58 kW

5.37 kW

COP Tj = +2°C

5.42

4.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.03 kW

3.82 kW

COP Tj = +7°C

7.26

5.39

Cdh Tj = +7 °C

0.974

0.980

Pdh Tj = 12°C

4.63 kW

4.46 kW

COP Tj = 12°C

9.00

6.81

Cdh Tj = +12 °C

0.972

0.978

Pdh Tj = Tbiv

10.19 kW

9.97 kW

COP Tj = Tbiv

3.09

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.19 kW

9.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.09

2.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3770 kWh

4896 kWh

Acond Grandis-R SP
Configure model
Model name
Acond Grandis-R SP
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.98 kW

6.94 kW

El input

1.26 kW

2.05 kW

COP

5.52

3.38

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

220 %

165 %

Prated

10.19 kW

9.97 kW

SCOP

5.58

4.21

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.97 kW

8.80 kW

COP Tj = -7°C

3.57

2.67

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.58 kW

5.37 kW

COP Tj = +2°C

5.42

4.10

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.03 kW

3.82 kW

COP Tj = +7°C

7.26

5.39

Cdh Tj = +7 °C

0.974

0.980

Pdh Tj = 12°C

4.63 kW

4.46 kW

COP Tj = 12°C

9.00

6.81

Cdh Tj = +12 °C

0.972

0.978

Pdh Tj = Tbiv

10.19 kW

9.97 kW

COP Tj = Tbiv

3.09

2.35

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.19 kW

9.97 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.09

2.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3770 kWh

4896 kWh

Acond Grandis-PR
Configure model
Model name
Acond Grandis-PR
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.80 kW

8.10 kW

El input

1.42 kW

2.52 kW

COP

5.51

3.22

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

158 %

Prated

11.79 kW

12.13 kW

SCOP

4.89

4.03

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.43 kW

10.73 kW

COP Tj = -7°C

3.11

2.55

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.18 kW

6.52 kW

COP Tj = +2°C

4.43

3.81

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.08 kW

4.17 kW

COP Tj = +7°C

7.31

5.39

Cdh Tj = +7 °C

0.900

0.980

Pdh Tj = 12°C

4.64 kW

4.46 kW

COP Tj = 12°C

9.00

6.81

Cdh Tj = +12 °C

0.971

0.977

Pdh Tj = Tbiv

10.43 kW

10.73 kW

COP Tj = Tbiv

3.11

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.41 kW

10.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.19 kW

Annual energy consumption Qhe

4979 kWh

4979 kWh

Acond Grandis-PR SP
Configure model
Model name
Acond Grandis-PR SP
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.80 kW

8.10 kW

El input

1.42 kW

2.52 kW

COP

5.51

3.22

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

158 %

Prated

11.79 kW

12.13 kW

SCOP

4.89

4.03

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.43 kW

10.73 kW

COP Tj = -7°C

3.11

2.55

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.18 kW

6.52 kW

COP Tj = +2°C

4.43

3.81

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.08 kW

4.17 kW

COP Tj = +7°C

7.31

5.39

Cdh Tj = +7 °C

0.900

0.980

Pdh Tj = 12°C

4.64 kW

4.46 kW

COP Tj = 12°C

9.00

6.81

Cdh Tj = +12 °C

0.971

0.977

Pdh Tj = Tbiv

10.43 kW

10.73 kW

COP Tj = Tbiv

3.11

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.41 kW

10.94 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.51

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

14 W

14 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.38 kW

1.19 kW

Annual energy consumption Qhe

4979 kWh

4979 kWh