Certificate holders

Subtype

Acond Grandis-N

Certificate Holder
Acond a.s.
Štěrboholská 1434/102a
102 00 Hostivař, Praha
Czech Republic
Registration number
037-0102-22 / rev. 1
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Acond Grandis-N
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,650 kg

Certification Date
07.12.2022
Testing basis
HP Keymark scheme rules rev. no. 10
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

Acond Grandis-N
Configure model
Model name
Acond Grandis-N
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.05 kW

3.30 kW

El input

0.55 kW

1.01 kW

COP

5.54

3.26

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

159 %

Prated

4.20 kW

4.00 kW

SCOP

5.38

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.72 kW

3.54 kW

COP Tj = -7°C

3.51

2.45

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.26 kW

2.15 kW

COP Tj = +2°C

5.25

3.98

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.52 kW

1.45 kW

COP Tj = +7°C

6.81

5.29

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.81 kW

1.75 kW

COP Tj = 12°C

9.14

7.16

Cdh Tj = +12 °C

0.953

0.957

Pdh Tj = Tbiv

4.20 kW

4.00 kW

COP Tj = Tbiv

3.02

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.20 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.02

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

16 W

PTO

15 W

16 W

PSB

15 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1613 kWh

2040 kWh

Acond Grandis-PN
Configure model
Model name
Acond Grandis-PN
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.10 kW

4.20 kW

El input

0.76 kW

1.32 kW

COP

5.41

3.18

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

137 %

Prated

6.00 kW

5.70 kW

SCOP

4.99

3.50

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.31 kW

5.04 kW

COP Tj = -7°C

2.90

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.23 kW

3.07 kW

COP Tj = +2°C

4.70

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.08 kW

1.97 kW

COP Tj = +7°C

7.30

5.29

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.81 kW

1.75 kW

COP Tj = 12°C

9.14

7.16

Cdh Tj = +12 °C

0.953

0.957

Pdh Tj = Tbiv

5.31 kW

5.04 kW

COP Tj = Tbiv

2.90

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.50 kW

4.45 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

16 W

PTO

15 W

16 W

PSB

15 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

1.25 kW

Annual energy consumption Qhe

2479 kWh

3363 kWh

Acond Grandis-N SP
Configure model
Model name
Acond Grandis-N SP
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

3.05 kW

3.30 kW

El input

0.55 kW

1.01 kW

COP

5.54

3.26

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

212 %

159 %

Prated

4.20 kW

4.00 kW

SCOP

5.38

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.72 kW

3.54 kW

COP Tj = -7°C

3.51

2.45

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.26 kW

2.15 kW

COP Tj = +2°C

5.25

3.98

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.52 kW

1.45 kW

COP Tj = +7°C

6.81

5.29

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.81 kW

1.75 kW

COP Tj = 12°C

9.14

7.16

Cdh Tj = +12 °C

0.953

0.957

Pdh Tj = Tbiv

4.20 kW

4.00 kW

COP Tj = Tbiv

3.02

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.20 kW

4.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.02

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

16 W

PTO

15 W

16 W

PSB

15 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1613 kWh

2040 kWh

Acond Grandis-PN SP
Configure model
Model name
Acond Grandis-PN SP
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.10 kW

4.20 kW

El input

0.76 kW

1.32 kW

COP

5.41

3.18

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

46 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

197 %

137 %

Prated

6.00 kW

5.70 kW

SCOP

4.99

3.50

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.31 kW

5.04 kW

COP Tj = -7°C

2.90

1.90

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.23 kW

3.07 kW

COP Tj = +2°C

4.70

3.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.08 kW

1.97 kW

COP Tj = +7°C

7.30

5.29

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.81 kW

1.75 kW

COP Tj = 12°C

9.14

7.16

Cdh Tj = +12 °C

0.953

0.957

Pdh Tj = Tbiv

5.31 kW

5.04 kW

COP Tj = Tbiv

2.90

1.90

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.50 kW

4.45 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

1.80

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

16 W

PTO

15 W

16 W

PSB

15 W

16 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.50 kW

1.25 kW

Annual energy consumption Qhe

2479 kWh

3363 kWh