26,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
101.40 kW
96.20 kW
El input
24.43 kW
34.60 kW
COP
4.15
2.78
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
82 dB(A)
82 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
134 %
Prated
73.80 kW
75.97 kW
SCOP
4.65
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
65.30 kW
67.20 kW
COP Tj = -7°C
3.16
2.03
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
39.75 kW
40.90 kW
COP Tj = +2°C
4.71
3.58
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
29.46 kW
26.30 kW
COP Tj = +7°C
5.63
4.10
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
24.70 kW
24.47 kW
COP Tj = 12°C
7.08
5.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
65.30 kW
67.20 kW
COP Tj = Tbiv
3.16
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
61.43 kW
64.08 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.97
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
35 °C
55 °C
Poff
135 W
135 W
PTO
200 W
200 W
PSB
135 W
135 W
PCK
135 W
135 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
12.39 kW
11.89 kW
Annual energy consumption Qhe
32811 kWh
45954 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
92.90 kW
88.90 kW
El input
22.07 kW
31.64 kW
COP
4.21
2.81
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
77 dB(A)
77 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
183 %
133 %
Prated
71.00 kW
71.00 kW
SCOP
4.65
3.40
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
62.80 kW
62.81 kW
COP Tj = -7°C
3.12
2.03
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
38.23 kW
38.23 kW
COP Tj = +2°C
4.71
3.58
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
29.46 kW
24.60 kW
COP Tj = +7°C
5.63
4.03
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
24.70 kW
24.47 kW
COP Tj = 12°C
7.08
5.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
62.80 kW
62.81 kW
COP Tj = Tbiv
3.12
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
67.00 kW
54.51 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.92
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
35 °C
55 °C
Poff
135 W
135 W
PTO
200 W
200 W
PSB
135 W
135 W
PCK
135 W
135 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
3.99 kW
16.49 kW
Annual energy consumption Qhe
31553 kWh
43133 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
110.70 kW
105.00 kW
El input
27.00 kW
38.89 kW
COP
4.10
2.70
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
83 dB(A)
83 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
181 %
132 %
Prated
78.00 kW
79.00 kW
SCOP
4.60
3.38
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
69.00 kW
69.90 kW
COP Tj = -7°C
3.14
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
42.00 kW
45.31 kW
COP Tj = +2°C
4.64
3.52
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
29.46 kW
28.70 kW
COP Tj = +7°C
5.53
4.08
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
24.70 kW
24.47 kW
COP Tj = 12°C
6.85
5.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
69.00 kW
69.90 kW
COP Tj = Tbiv
3.14
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
67.00 kW
64.08 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.95
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
35 °C
55 °C
Poff
135 W
135 W
PTO
200 W
200 W
PSB
135 W
135 W
PCK
135 W
135 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
11.00 kW
14.94 kW
Annual energy consumption Qhe
35013 kWh
48229 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
98.40 kW
94.00 kW
El input
23.65 kW
34.43 kW
COP
4.16
2.73
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
78 dB(A)
78 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
132 %
Prated
73.48 kW
74.04 kW
SCOP
4.58
3.37
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
65.00 kW
65.50 kW
COP Tj = -7°C
3.10
2.01
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
39.57 kW
39.87 kW
COP Tj = +2°C
4.64
3.52
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
29.46 kW
25.60 kW
COP Tj = +7°C
5.53
4.05
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
24.70 kW
24.47 kW
COP Tj = 12°C
6.85
5.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
65.00 kW
65.50 kW
COP Tj = Tbiv
3.10
2.01
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
67.00 kW
56.84 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.90
1.65
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
35 °C
55 °C
Poff
135 W
135 W
PTO
200 W
200 W
PSB
135 W
135 W
PCK
135 W
135 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
6.48 kW
17.20 kW
Annual energy consumption Qhe
33154 kWh
45416 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
130.00 kW
127.00 kW
El input
32.50 kW
47.92 kW
COP
4.00
2.65
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
84 dB(A)
84 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
132 %
Prated
80.60 kW
83.47 kW
SCOP
4.56
3.36
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
71.30 kW
73.84 kW
COP Tj = -7°C
3.13
2.00
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
44.39 kW
45.31 kW
COP Tj = +2°C
4.60
3.49
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
29.46 kW
29.19 kW
COP Tj = +7°C
5.41
4.06
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
24.70 kW
24.47 kW
COP Tj = 12°C
6.71
5.75
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
71.30 kW
73.84 kW
COP Tj = Tbiv
3.13
2.00
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
67.00 kW
64.08 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.93
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
35 °C
55 °C
Poff
135 W
135 W
PTO
200 W
200 W
PSB
135 W
135 W
PCK
135 W
135 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
13.60 kW
19.39 kW
Annual energy consumption Qhe
36499 kWh
51290 kWh