3,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
20.25 kW
18.86 kW
El input
4.36 kW
5.89 kW
COP
4.64
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
153 %
127 %
Prated
30.00 kW
30.00 kW
SCOP
3.90
3.25
Tbiv
-5 °C
-5 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
24.10 kW
25.90 kW
COP Tj = -7°C
2.86
2.29
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
16.53 kW
16.01 kW
COP Tj = +2°C
3.89
3.23
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
21.27 kW
20.44 kW
COP Tj = +7°C
5.61
4.68
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
24.80 kW
23.90 kW
COP Tj = 12°C
6.42
5.76
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
24.50 kW
24.00 kW
COP Tj = Tbiv
2.99
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
24.60 kW
24.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.57
2.13
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
70 °C
70 °C
Poff
8 W
8 W
PTO
12 W
12 W
PSB
8 W
8 W
PCK
12 W
12 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.40 kW
5.60 kW
Annual energy consumption Qhe
15908 kWh
19088 kWh