0,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.90 kW
10.10 kW
El input
2.37 kW
3.16 kW
COP
4.60
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
150 %
116 %
Prated
21.00 kW
18.00 kW
SCOP
3.83
2.97
Tbiv
-6 °C
-6 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
17.10 kW
14.70 kW
COP Tj = -7°C
2.58
1.97
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
11.12 kW
11.22 kW
COP Tj = +2°C
3.79
2.99
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
11.12 kW
10.90 kW
COP Tj = +7°C
5.61
4.51
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
12.45 kW
12.21 kW
COP Tj = 12°C
5.84
4.81
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
17.36 kW
14.92 kW
COP Tj = Tbiv
2.66
1.95
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.25 kW
13.97 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.40
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
70 °C
70 °C
Poff
7 W
7 W
PTO
10 W
10 W
PSB
7 W
7 W
PCK
10 W
10 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.75 kW
4.03 kW
Annual energy consumption Qhe
11314 kWh
12525 kWh