Certificate holders

Subtype

HRC70 17 kW

Certificate Holder
Intuis
Rue de la République
80210 Feuquières‑en‑Vimeu
France
Registration number
007-DP0187
Certification Body
Kiwa Nederland B.V.
Subtype title
HRC70 17 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,900 kg

Certification Date
26.04.2024
Testing basis
European KEYMARK Scheme for Heat Pumps (v11)
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

HRC70 17 kW /3 tri
Configure model
Model name
HRC70 17 kW /3 tri
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.80 kW

7.20 kW

El input

1.63 kW

2.25 kW

COP

4.79

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

150 %

125 %

Prated

13.53 kW

15.10 kW

SCOP

3.81

3.19

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.70 kW

11.51 kW

COP Tj = -7°C

2.84

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.96 kW

7.91 kW

COP Tj = +2°C

3.77

3.06

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.33 kW

7.07 kW

COP Tj = +7°C

5.22

4.35

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

8.33 kW

8.35 kW

COP Tj = 12°C

5.81

5.31

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.93 kW

12.25 kW

COP Tj = Tbiv

3.03

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.99 kW

10.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.54 kW

4.51 kW

Annual energy consumption Qhe

7329 kWh

9779 kWh

HRC70 17 kW /3 mono
Configure model
Model name
HRC70 17 kW /3 mono
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.80 kW

7.20 kW

El input

1.63 kW

2.25 kW

COP

4.79

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

150 %

125 %

Prated

13.53 kW

15.10 kW

SCOP

3.81

3.19

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.70 kW

11.51 kW

COP Tj = -7°C

2.84

2.28

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.96 kW

7.91 kW

COP Tj = +2°C

3.77

3.06

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

7.33 kW

7.07 kW

COP Tj = +7°C

5.22

4.35

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

8.33 kW

8.35 kW

COP Tj = 12°C

5.81

5.31

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.93 kW

12.25 kW

COP Tj = Tbiv

3.03

2.55

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.99 kW

10.59 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

70 °C

70 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

7 W

7 W

PCK

9 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.54 kW

4.51 kW

Annual energy consumption Qhe

7329 kWh

9779 kWh