2,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.58 kW
11.14 kW
El input
1.85 kW
4.14 kW
COP
5.19
2.69
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
35 dB(A)
Sound power level outdoor
57 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
127 %
Prated
11.60 kW
11.04 kW
SCOP
4.70
3.24
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
10.26 kW
9.76 kW
COP Tj = -7°C
3.38
1.89
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.30 kW
6.11 kW
COP Tj = +2°C
4.69
3.22
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.13 kW
5.93 kW
COP Tj = +7°C
6.29
4.76
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.97 kW
6.92 kW
COP Tj = 12°C
6.02
5.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.26 kW
9.76 kW
COP Tj = Tbiv
3.38
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.23 kW
9.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.02
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
56 °C
56 °C
Poff
13 W
13 W
PTO
39 W
39 W
PSB
13 W
13 W
PCK
41 W
41 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.37 kW
1.91 kW
Annual energy consumption Qhe
5096 kWh
7039 kWh
EN 12102-2
Sound power level indoor
40 dB(A)
Sound power level outdoor
61 dB(A)
Operating test
Domestic Hot Water (DHW)
Average Climate
EN 12102-2
Sound power level indoor
40 dB(A)
Sound power level outdoor
61 dB(A)
EN 16147
Declared load profile
XL
Efficiency ηDHW
125 %
COP
3.00
Heating up time
23:8:13 h:min
Standby power input
46.0 W
Reference hot water temperature
44.7 °C
Mixed water at 40°C
219 l
Operating test
EN 16147
Temperature operating range
passed
Safety devices checking test
passed
Condensate draining
passed
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.58 kW
11.14 kW
El input
1.85 kW
4.14 kW
COP
5.19
2.69
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
35 dB(A)
Sound power level outdoor
57 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
127 %
Prated
11.60 kW
11.04 kW
SCOP
4.70
3.24
Tbiv
-7 °C
-7 °C
TOL
-25 °C
-25 °C
Pdh Tj = -7°C
10.26 kW
9.76 kW
COP Tj = -7°C
3.38
1.89
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.30 kW
6.11 kW
COP Tj = +2°C
4.69
3.22
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.13 kW
5.93 kW
COP Tj = +7°C
6.29
4.76
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.97 kW
6.92 kW
COP Tj = 12°C
6.02
5.80
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.26 kW
9.76 kW
COP Tj = Tbiv
3.38
1.89
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.23 kW
9.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.02
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
56 °C
56 °C
Poff
13 W
13 W
PTO
39 W
39 W
PSB
13 W
13 W
PCK
41 W
41 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.37 kW
1.91 kW
Annual energy consumption Qhe
5096 kWh
7039 kWh
EN 12102-2
Sound power level indoor
40 dB(A)
Sound power level outdoor
61 dB(A)
Operating test
Domestic Hot Water (DHW)
Average Climate
EN 12102-2
Sound power level indoor
40 dB(A)
Sound power level outdoor
61 dB(A)
EN 16147
Declared load profile
XL
Efficiency ηDHW
125 %
COP
3.00
Heating up time
23:8:13 h:min
Standby power input
46.0 W
Reference hot water temperature
44.7 °C
Mixed water at 40°C
219 l
Operating test
EN 16147
Temperature operating range
passed
Safety devices checking test
passed
Condensate draining
passed