Certificate holders

Subtype

DC Inverter Air to Water Heat Pump Unit- R290- 08- C

Certificate Holder
Zhongshan Amitime Electric Co., Ltd
5th Yandong Rd
Zhongshan City - Guangdong
China
Registration number
041-K027-14
Certification Body
BRE
Subtype title
DC Inverter Air to Water Heat Pump Unit- R290- 08- C
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,700 kg

Certification Date
22.09.2023
Testing basis
Heat Pump Keymark Scheme Rules Rev 12
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

Indoor unit: PAVH-06-20V1GX-250L/IX, Outdoor unit: PAVH-08V1GXX
Configure model
Model name
Indoor unit: PAVH-06-20V1GX-250L/IX, Outdoor unit: PAVH-08V1GXX
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.77 kW

5.57 kW

El input

1.14 kW

1.65 kW

COP

5.07

3.37

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

54 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

143 %

Prated

6.93 kW

6.40 kW

SCOP

4.85

3.65

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

6.13 kW

5.67 kW

COP Tj = -7°C

3.09

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.83 kW

3.59 kW

COP Tj = +2°C

4.67

3.64

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.29 kW

3.02 kW

COP Tj = +7°C

6.81

4.99

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.89 kW

3.62 kW

COP Tj = 12°C

9.50

6.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.13 kW

5.67 kW

COP Tj = Tbiv

3.09

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.64 kW

5.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

56 °C

56 °C

Poff

20 W

20 W

PTO

23 W

23 W

PSB

20 W

20 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.29 kW

1.32 kW

Annual energy consumption Qhe

2953 kWh

3622 kWh

EN 12102-2

Sound power level indoor

33 dB(A)

Sound power level outdoor

56 dB(A)

Operating test

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

33 dB(A)

Sound power level outdoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.12

Heating up time

43:17:50 h:min

Standby power input

26.0 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

222 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed

Indoor unit: ecoSTAR All-in-one, Outdoor unit: ecoSTAR08
Configure model
Model name
Indoor unit: ecoSTAR All-in-one, Outdoor unit: ecoSTAR08
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.77 kW

5.57 kW

El input

1.14 kW

1.65 kW

COP

5.07

3.37

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

33 dB(A)

33 dB(A)

Sound power level outdoor

54 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

143 %

Prated

6.93 kW

6.40 kW

SCOP

4.85

3.65

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

6.13 kW

5.67 kW

COP Tj = -7°C

3.09

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.83 kW

3.59 kW

COP Tj = +2°C

4.67

3.64

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.29 kW

3.02 kW

COP Tj = +7°C

6.81

4.99

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.89 kW

3.62 kW

COP Tj = 12°C

9.50

6.28

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

6.13 kW

5.67 kW

COP Tj = Tbiv

3.09

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.64 kW

5.09 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.98

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

56 °C

56 °C

Poff

20 W

20 W

PTO

23 W

23 W

PSB

20 W

20 W

PCK

30 W

30 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.29 kW

1.32 kW

Annual energy consumption Qhe

2953 kWh

3622 kWh

EN 12102-2

Sound power level indoor

33 dB(A)

Sound power level outdoor

56 dB(A)

Operating test

Domestic Hot Water (DHW)

Average Climate

EN 12102-2

Sound power level indoor

33 dB(A)

Sound power level outdoor

56 dB(A)

EN 16147

Declared load profile

L

Efficiency ηDHW

130 %

COP

3.12

Heating up time

43:17:50 h:min

Standby power input

26.0 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

222 l

Operating test

EN 16147

Temperature operating range

passed

Safety devices checking test

passed

Condensate draining

passed