Certificate holders

Subtype

DE DIETRICH MMTC R32 020

Certificate Holder
BDR Thermea FR (DE DIETRICH)
57 rue de la Gare
67580 Mertzwiller
France
Registration number
007-DO0154
Certification Body
Kiwa Nederland B.V.
Subtype title
DE DIETRICH MMTC R32 020
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

4,800 kg

Certification Date
27.06.2023
Testing basis
European KEYMARK Scheme for Heat Pumps (v11)
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

MMTC R32 020
Configure model
Model name
MMTC R32 020
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

21.22 kW

15.78 kW

El input

4.84 kW

5.48 kW

COP

4.38

2.88

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

6.11 kW

4.31 kW

Cooling capacity

20.04

21.31

EER

3.28

4.95

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

20.04 kW

21.31 kW

SEER

5.03

7.56

Pdc Tj = 35°C

20.04 kW

21.31 kW

EER Tj = 35°C

3.28

4.95

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

15.79 kW

16.61 kW

EER Tj = 30°C

4.38

6.41

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

9.30 kW

10.22 kW

EER Tj = 25°C

5.64

9.04

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

6.39 kW

7.75 kW

EER Tj = 20°C

7.22

11.09

Cdc Tj = 20 °C

0.900

0.900

Poff

0 W

0 W

PTO

26 W

26 W

PSB

26 W

26 W

PCK

26 W

26 W

Annual energy consumption Qce

12024 kWh

12786 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174 %

130 %

Prated

16.80 kW

13.80 kW

SCOP

4.42

3.33

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.44 kW

11.94 kW

COP Tj = -7°C

2.78

1.95

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.53 kW

6.97 kW

COP Tj = +2°C

4.59

3.23

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

6.37 kW

4.80 kW

COP Tj = +7°C

5.22

4.21

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

6.28 kW

6.10 kW

COP Tj = 12°C

7.76

7.04

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.78 kW

11.63 kW

COP Tj = Tbiv

3.10

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.87 kW

13.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

58 °C

58 °C

Poff

0 W

0 W

PTO

58 W

58 W

PSB

58 W

58 W

PCK

60 W

60 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.93 kW

0.60 kW

Annual energy consumption Qhe

7847 kWh

8573 kWh

MMTC R32 020 HR
Configure model
Model name
MMTC R32 020 HR
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
n/a

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

21.22 kW

15.78 kW

El input

4.84 kW

5.48 kW

COP

4.38

2.88

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

6.11 kW

4.31 kW

Cooling capacity

20.04

21.31

EER

3.28

4.95

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

20.04 kW

21.31 kW

SEER

5.03

7.56

Pdc Tj = 35°C

20.04 kW

21.31 kW

EER Tj = 35°C

3.28

4.95

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

15.79 kW

16.61 kW

EER Tj = 30°C

4.38

6.41

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

9.30 kW

10.22 kW

EER Tj = 25°C

5.64

9.04

Cdc Tj = 25 °C

1.000

1.000

Pdc Tj = 20°C

6.39 kW

7.75 kW

EER Tj = 20°C

7.22

11.09

Cdc Tj = 20 °C

0.900

0.900

Poff

0 W

0 W

PTO

26 W

26 W

PSB

26 W

26 W

PCK

26 W

26 W

Annual energy consumption Qce

12024 kWh

12786 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

69 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174 %

130 %

Prated

16.80 kW

13.80 kW

SCOP

4.42

3.33

Tbiv

-5 °C

-5 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.44 kW

11.94 kW

COP Tj = -7°C

2.78

1.95

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.53 kW

6.97 kW

COP Tj = +2°C

4.59

3.23

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

6.37 kW

4.80 kW

COP Tj = +7°C

5.22

4.21

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

6.28 kW

6.10 kW

COP Tj = 12°C

7.76

7.04

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.78 kW

11.63 kW

COP Tj = Tbiv

3.10

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.87 kW

13.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.67

1.74

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

58 °C

58 °C

Poff

0 W

0 W

PTO

58 W

58 W

PSB

58 W

58 W

PCK

60 W

60 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.93 kW

0.60 kW

Annual energy consumption Qhe

7847 kWh

8573 kWh