Certificate holders

Subtype

AEROTOP SX13

Certificate Holder
ELCO GmbH
Hohenzollernstrasse 31
72379 Hechingen
Germany
Registration number
011-1W0659
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
AEROTOP SX13
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R32
Mass of Refrigerant

2,600 kg

Certification Date
31.07.2023
Testing basis
HP KEYMARK certification scheme rules V12
Generate PDF Export model CSV
  • Number of models 1

Models

AEROTOP SX13
Configure model
Model name
AEROTOP SX13
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Medium temperature

Heat output

n/a

9.51 kW

El input

n/a

3.02 kW

COP

n/a

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Medium temperature

Sound power level outdoor

n/a

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

258 %

178 %

Prated

7.48 kW

6.86 kW

SCOP

6.52

4.53

Tbiv

2 °C

2 °C

TOL

-20 °C

-20 °C

Pdh Tj = +2°C

7.48 kW

6.86 kW

COP Tj = +2°C

4.27

2.67

Cdh Tj = +2 °C

0.989

0.989

Pdh Tj = +7°C

4.55 kW

4.35 kW

COP Tj = +7°C

5.83

3.60

Cdh Tj = +7 °C

0.978

0.978

Pdh Tj = 12°C

4.64 kW

4.74 kW

COP Tj = 12°C

8.07

6.37

Cdh Tj = +12 °C

0.968

0.968

Pdh Tj = Tbiv

7.48 kW

6.86 kW

COP Tj = Tbiv

4.27

2.67

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.48 kW

6.86 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.27

2.67

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

21 W

21 W

PTO

15 W

15 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1534 kWh

2024 kWh

Colder Climate

EN 12102-1

Medium temperature

Sound power level outdoor

n/a

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

143 %

119 %

Prated

21.00 kW

20.72 kW

SCOP

3.66

3.05

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

12.71 kW

12.54 kW

COP Tj = -7°C

3.21

2.65

Cdh Tj = -7 °C

0.996

0.996

Pdh Tj = +2°C

7.75 kW

7.09 kW

COP Tj = +2°C

4.97

3.96

Cdh Tj = +2 °C

0.989

0.989

Pdh Tj = +7°C

5.20 kW

5.08 kW

COP Tj = +7°C

6.70

5.60

Cdh Tj = +7 °C

0.978

0.978

Pdh Tj = 12°C

4.62 kW

4.67 kW

COP Tj = 12°C

7.49

7.60

Cdh Tj = +12 °C

0.968

0.968

Pdh Tj = Tbiv

12.71 kW

12.54 kW

COP Tj = Tbiv

3.21

2.65

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.26 kW

7.91 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.40

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

21 W

21 W

PTO

15 W

15 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

21.00 kW

20.72 kW

Annual energy consumption Qhe

14150 kWh

16733 kWh

Pdh Tj = -15°C (if TOL<-20°C)

 

 

COP Tj = -15°C (if TOL<-20°C)

 

 

Cdh Tj = -15 °C

 

 

Average Climate

EN 12102-1

Medium temperature

Sound power level outdoor

n/a

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

151 %

Prated

14.18 kW

13.53 kW

SCOP

4.76

3.85

Tbiv

-7 °C

-7 °C

TOL

-20 °C

-20 °C

Pdh Tj = -7°C

12.54 kW

11.97 kW

COP Tj = -7°C

2.97

2.36

Cdh Tj = -7 °C

0.996

0.996

Pdh Tj = +2°C

7.54 kW

7.25 kW

COP Tj = +2°C

4.57

3.75

Cdh Tj = +2 °C

0.989

0.989

Pdh Tj = +7°C

4.98 kW

4.87 kW

COP Tj = +7°C

6.40

5.03

Cdh Tj = +7 °C

0.978

0.978

Pdh Tj = 12°C

4.62 kW

4.69 kW

COP Tj = 12°C

8.49

7.22

Cdh Tj = +12 °C

0.968

0.968

Pdh Tj = Tbiv

12.54 kW

11.97 kW

COP Tj = Tbiv

2.97

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.50 kW

10.63 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.71

1.99

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

60 °C

60 °C

Poff

21 W

21 W

PTO

15 W

15 W

PSB

21 W

21 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.68 kW

2.90 kW

Annual energy consumption Qhe

6152 kWh

7254 kWh