2,600 kg
Heating
EN 14511-2
Medium temperature
Heat output
n/a
9.51 kW
El input
n/a
3.02 kW
COP
n/a
3.15
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Medium temperature
Sound power level outdoor
n/a
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
258 %
178 %
Prated
7.48 kW
6.86 kW
SCOP
6.52
4.53
Tbiv
2 °C
2 °C
TOL
-20 °C
-20 °C
Pdh Tj = +2°C
7.48 kW
6.86 kW
COP Tj = +2°C
4.27
2.67
Cdh Tj = +2 °C
0.989
0.989
Pdh Tj = +7°C
4.55 kW
4.35 kW
COP Tj = +7°C
5.83
3.60
Cdh Tj = +7 °C
0.978
0.978
Pdh Tj = 12°C
4.64 kW
4.74 kW
COP Tj = 12°C
8.07
6.37
Cdh Tj = +12 °C
0.968
0.968
Pdh Tj = Tbiv
7.48 kW
6.86 kW
COP Tj = Tbiv
4.27
2.67
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.48 kW
6.86 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.27
2.67
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
21 W
21 W
PTO
15 W
15 W
PSB
21 W
21 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1534 kWh
2024 kWh
Colder Climate
EN 12102-1
Medium temperature
Sound power level outdoor
n/a
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
143 %
119 %
Prated
21.00 kW
20.72 kW
SCOP
3.66
3.05
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
12.71 kW
12.54 kW
COP Tj = -7°C
3.21
2.65
Cdh Tj = -7 °C
0.996
0.996
Pdh Tj = +2°C
7.75 kW
7.09 kW
COP Tj = +2°C
4.97
3.96
Cdh Tj = +2 °C
0.989
0.989
Pdh Tj = +7°C
5.20 kW
5.08 kW
COP Tj = +7°C
6.70
5.60
Cdh Tj = +7 °C
0.978
0.978
Pdh Tj = 12°C
4.62 kW
4.67 kW
COP Tj = 12°C
7.49
7.60
Cdh Tj = +12 °C
0.968
0.968
Pdh Tj = Tbiv
12.71 kW
12.54 kW
COP Tj = Tbiv
3.21
2.65
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.26 kW
7.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.08
1.40
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
21 W
21 W
PTO
15 W
15 W
PSB
21 W
21 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
21.00 kW
20.72 kW
Annual energy consumption Qhe
14150 kWh
16733 kWh
Pdh Tj = -15°C (if TOL<-20°C)
COP Tj = -15°C (if TOL<-20°C)
Cdh Tj = -15 °C
Average Climate
EN 12102-1
Medium temperature
Sound power level outdoor
n/a
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
151 %
Prated
14.18 kW
13.53 kW
SCOP
4.76
3.85
Tbiv
-7 °C
-7 °C
TOL
-20 °C
-20 °C
Pdh Tj = -7°C
12.54 kW
11.97 kW
COP Tj = -7°C
2.97
2.36
Cdh Tj = -7 °C
0.996
0.996
Pdh Tj = +2°C
7.54 kW
7.25 kW
COP Tj = +2°C
4.57
3.75
Cdh Tj = +2 °C
0.989
0.989
Pdh Tj = +7°C
4.98 kW
4.87 kW
COP Tj = +7°C
6.40
5.03
Cdh Tj = +7 °C
0.978
0.978
Pdh Tj = 12°C
4.62 kW
4.69 kW
COP Tj = 12°C
8.49
7.22
Cdh Tj = +12 °C
0.968
0.968
Pdh Tj = Tbiv
12.54 kW
11.97 kW
COP Tj = Tbiv
2.97
2.36
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.50 kW
10.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.71
1.99
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
60 °C
60 °C
Poff
21 W
21 W
PTO
15 W
15 W
PSB
21 W
21 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.68 kW
2.90 kW
Annual energy consumption Qhe
6152 kWh
7254 kWh