Certificate holders

Subtype

CHA-Monoblock 16

Certificate Holder
WOLF GmbH
Industriestr. 1
84048 Mainburg
Germany
Registration number
011-1W0514
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
CHA-Monoblock 16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

3,800 kg

Certification Date
30.11.2021
Testing basis
European KEYMARK Scheme for Heat Pumps Rev. 9 (as of 2021-03)
Generate PDF Export model CSV
  • Number of models 3

Models

CHA-16/20-400V-M2 CS-e9-C2
Configure model
Model name
CHA-16/20-400V-M2 CS-e9-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.54 kW

20.60 kW

El input

4.44 kW

7.04 kW

COP

4.63

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.27 kW

1.68 kW

Cooling capacity

8.35

9.75

EER

3.68

5.82

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

14.53 kW

15.80 kW

SEER

3.39

5.09

Pdc Tj = 35°C

14.53 kW

15.80 kW

EER Tj = 35°C

2.74

4.59

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

10.45 kW

11.82 kW

EER Tj = 30°C

4.10

6.12

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.63 kW

7.01 kW

EER Tj = 25°C

3.97

5.49

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

4.94 kW

6.42 kW

EER Tj = 20°C

3.49

4.87

Cdc Tj = 20 °C

0.983

0.982

Poff

20 W

20 W

PTO

24 W

24 W

PSB

23 W

23 W

PCK

0 W

0 W

Annual energy consumption Qce

1499 kWh

1088 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

266 %

185 %

Prated

15.17 kW

15.98 kW

SCOP

6.72

4.71

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

15.17 kW

15.98 kW

COP Tj = +2°C

3.35

2.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.21 kW

9.98 kW

COP Tj = +7°C

6.26

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.12 kW

6.62 kW

COP Tj = 12°C

8.15

6.03

Cdh Tj = +12 °C

0.973

0.978

Pdh Tj = Tbiv

15.17 kW

15.98 kW

COP Tj = Tbiv

3.35

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.17 kW

15.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3017 kWh

4538 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

137 %

Prated

15.64 kW

15.46 kW

SCOP

4.65

3.50

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.73 kW

9.84 kW

COP Tj = -7°C

3.95

2.88

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.95 kW

6.17 kW

COP Tj = +2°C

5.84

4.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.38 kW

6.02 kW

COP Tj = +7°C

7.12

5.60

Cdh Tj = +7 °C

0.974

0.978

Pdh Tj = 12°C

6.69 kW

6.76 kW

COP Tj = 12°C

7.96

6.60

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

12.76 kW

12.61 kW

COP Tj = Tbiv

2.68

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.06 kW

10.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.23

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.58 kW

5.19 kW

Annual energy consumption Qhe

8292 kWh

10876 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.76

12.61

COP Tj = -15°C (if TOL<-20°C)

2.68

1.87

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

154 %

Prated

13.52 kW

14.55 kW

SCOP

5.46

3.92

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.17 kW

12.64 kW

COP Tj = -7°C

3.40

2.31

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.30 kW

7.73 kW

COP Tj = +2°C

5.42

3.86

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.33 kW

5.87 kW

COP Tj = +7°C

7.09

5.21

Cdh Tj = +7 °C

0.973

0.979

Pdh Tj = 12°C

7.13 kW

6.80 kW

COP Tj = 12°C

8.53

6.56

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

13.52 kW

14.55 kW

COP Tj = Tbiv

2.61

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.52 kW

14.55 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5118 kWh

7675 kWh

CHA-16/20-400V-M2 CS-C2
Configure model
Model name
CHA-16/20-400V-M2 CS-C2
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.54 kW

20.60 kW

El input

4.44 kW

7.04 kW

COP

4.63

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.27 kW

1.68 kW

Cooling capacity

8.35

9.75

EER

3.68

5.82

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

14.53 kW

15.80 kW

SEER

3.39

5.09

Pdc Tj = 35°C

14.53 kW

15.80 kW

EER Tj = 35°C

2.74

4.59

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

10.45 kW

11.82 kW

EER Tj = 30°C

4.10

6.12

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.63 kW

7.01 kW

EER Tj = 25°C

3.97

5.49

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

4.94 kW

6.42 kW

EER Tj = 20°C

3.49

4.87

Cdc Tj = 20 °C

0.983

0.982

Poff

20 W

20 W

PTO

24 W

24 W

PSB

23 W

23 W

PCK

0 W

0 W

Annual energy consumption Qce

1499 kWh

1088 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

266 %

185 %

Prated

15.17 kW

15.98 kW

SCOP

6.72

4.71

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

15.17 kW

15.98 kW

COP Tj = +2°C

3.35

2.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.21 kW

9.98 kW

COP Tj = +7°C

6.26

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.12 kW

6.62 kW

COP Tj = 12°C

8.15

6.03

Cdh Tj = +12 °C

0.973

0.978

Pdh Tj = Tbiv

15.17 kW

15.98 kW

COP Tj = Tbiv

3.35

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.17 kW

15.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

10876 W

PTO

24 W

20 W

PSB

23 W

24 W

PCK

0 W

23 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3017 kWh

4538 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

154 %

Prated

13.52 kW

14.55 kW

SCOP

5.46

3.92

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.17 kW

12.64 kW

COP Tj = -7°C

3.40

2.31

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.30 kW

7.73 kW

COP Tj = +2°C

5.42

3.86

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.33 kW

5.87 kW

COP Tj = +7°C

7.09

5.21

Cdh Tj = +7 °C

0.973

0.979

Pdh Tj = 12°C

7.13 kW

6.80 kW

COP Tj = 12°C

8.53

6.56

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

13.52 kW

14.55 kW

COP Tj = Tbiv

2.61

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.52 kW

14.55 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

10876 W

PTO

24 W

20 W

PSB

23 W

24 W

PCK

0 W

23 W

Supplementary Heater: Type of energy input

n/a

n/a

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5118 kWh

7675 kWh

CHA-16/20-400V-M2 CS-e9-C2 + SEW-2-300 (CHA-16/20-400V-M2 CC-300-S50-e9-C2)
Configure model
Model name
CHA-16/20-400V-M2 CS-e9-C2 + SEW-2-300 (CHA-16/20-400V-M2 CC-300-S50-e9-C2)
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

20.54 kW

20.60 kW

El input

4.44 kW

7.04 kW

COP

4.63

2.93

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.27 kW

1.68 kW

Cooling capacity

8.35

9.75

EER

3.68

5.82

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

14.53 kW

15.80 kW

SEER

3.39

5.09

Pdc Tj = 35°C

14.53 kW

15.80 kW

EER Tj = 35°C

2.74

4.59

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

10.45 kW

11.82 kW

EER Tj = 30°C

4.10

6.12

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

6.63 kW

7.01 kW

EER Tj = 25°C

3.97

5.49

Cdc Tj = 25 °C

0.250

0.250

Pdc Tj = 20°C

4.94 kW

6.42 kW

EER Tj = 20°C

3.49

4.87

Cdc Tj = 20 °C

0.983

0.982

Poff

20 W

20 W

PTO

24 W

24 W

PSB

23 W

23 W

PCK

0 W

0 W

Annual energy consumption Qce

1499 kWh

1088 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

266 %

185 %

Prated

15.17 kW

15.98 kW

SCOP

6.72

4.71

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

15.17 kW

15.98 kW

COP Tj = +2°C

3.35

2.30

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

10.21 kW

9.98 kW

COP Tj = +7°C

6.26

4.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

7.12 kW

6.62 kW

COP Tj = 12°C

8.15

6.03

Cdh Tj = +12 °C

0.973

0.978

Pdh Tj = Tbiv

15.17 kW

15.98 kW

COP Tj = Tbiv

3.35

2.30

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

15.17 kW

15.98 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.35

2.30

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3017 kWh

4538 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

137 %

Prated

15.64 kW

15.46 kW

SCOP

4.65

3.50

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.73 kW

9.84 kW

COP Tj = -7°C

3.95

2.88

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.95 kW

6.17 kW

COP Tj = +2°C

5.84

4.49

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.38 kW

6.02 kW

COP Tj = +7°C

7.12

5.60

Cdh Tj = +7 °C

0.974

0.978

Pdh Tj = 12°C

6.69 kW

6.76 kW

COP Tj = 12°C

7.96

6.60

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

12.76 kW

12.61 kW

COP Tj = Tbiv

2.68

1.87

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.06 kW

10.27 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.23

1.35

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

6.58 kW

5.19 kW

Annual energy consumption Qhe

8292 kWh

10876 kWh

Pdh Tj = -15°C (if TOL<-20°C)

12.76

12.61

COP Tj = -15°C (if TOL<-20°C)

2.68

1.87

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

Sound power level outdoor

52 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

154 %

Prated

13.52 kW

14.55 kW

SCOP

5.46

3.92

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.17 kW

12.64 kW

COP Tj = -7°C

3.40

2.31

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.30 kW

7.73 kW

COP Tj = +2°C

5.42

3.86

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

6.33 kW

5.87 kW

COP Tj = +7°C

7.09

5.21

Cdh Tj = +7 °C

0.973

0.979

Pdh Tj = 12°C

7.13 kW

6.80 kW

COP Tj = 12°C

8.53

6.56

Cdh Tj = +12 °C

0.972

0.977

Pdh Tj = Tbiv

13.52 kW

14.55 kW

COP Tj = Tbiv

2.61

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.52 kW

14.55 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

65 °C

65 °C

Poff

20 W

20 W

PTO

24 W

24 W

PSB

23 W

23 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5118 kWh

7675 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

138 %

COP

3.46

Heating up time

2:03 h:min

Standby power input

61.3 W

Reference hot water temperature

49.6 °C

Mixed water at 40°C

313 l

Colder Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

102 %

COP

2.54

Heating up time

1:59 h:min

Standby power input

79.1 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

316 l

Average Climate

EN 16147

Declared load profile

XXL

Efficiency ηDHW

118 %

COP

2.94

Heating up time

1:58 h:min

Standby power input

62.5 W

Reference hot water temperature

49.5 °C

Mixed water at 40°C

313 l