3,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
24.15 kW
23.42 kW
El input
5.56 kW
8.24 kW
COP
4.34
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
70 dB(A)
71 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
121 %
Prated
18.04 kW
18.19 kW
SCOP
4.10
3.11
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
15.96 kW
16.09 kW
COP Tj = -7°C
2.93
2.07
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
9.86 kW
9.81 kW
COP Tj = +2°C
3.94
3.02
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
9.66 kW
9.61 kW
COP Tj = +7°C
4.93
3.76
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
11.44 kW
11.41 kW
COP Tj = 12°C
6.57
5.13
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
15.96 kW
16.09 kW
COP Tj = Tbiv
2.93
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
18.13 kW
18.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.53
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
59 W
59 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.01 kW
Annual energy consumption Qhe
9081 kWh
12100 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
24.15 kW
23.42 kW
El input
5.56 kW
8.24 kW
COP
4.34
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
70 dB(A)
71 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
121 %
Prated
18.04 kW
18.19 kW
SCOP
4.10
3.11
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
15.96 kW
16.09 kW
COP Tj = -7°C
2.93
2.07
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
9.86 kW
9.81 kW
COP Tj = +2°C
3.94
3.02
Cdh Tj = +2 °C
0.990
0.990
Pdh Tj = +7°C
9.66 kW
9.61 kW
COP Tj = +7°C
4.93
3.76
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
11.44 kW
11.41 kW
COP Tj = 12°C
6.57
5.13
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
15.96 kW
16.09 kW
COP Tj = Tbiv
2.93
2.07
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
18.13 kW
18.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.53
1.94
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
25 W
25 W
PTO
25 W
25 W
PSB
25 W
25 W
PCK
59 W
59 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.01 kW
Annual energy consumption Qhe
9081 kWh
12100 kWh