1,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.60 kW
11.61 kW
El input
2.61 kW
3.60 kW
COP
4.83
3.22
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
3.74 kW
Cooling capacity
10.67
EER
2.85
EN 14825
+7°C/+12°C
Pdesignc
10.67 kW
SEER
4.72
Pdc Tj = 35°C
10.67 kW
EER Tj = 35°C
2.85
Cdc Tj = 35 °C
1.000
Pdc Tj = 30°C
8.17 kW
EER Tj = 30°C
4.04
Cdc Tj = 30 °C
1.000
Pdc Tj = 25°C
5.10 kW
EER Tj = 25°C
5.26
Cdc Tj = 25 °C
1.000
Pdc Tj = 20°C
4.31 kW
EER Tj = 20°C
6.63
Cdc Tj = 20 °C
0.966
Poff
22 W
PTO
0 W
PSB
28 W
PCK
0 W
Annual energy consumption Qce
1356 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
59 dB(A)
59 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
140 %
Prated
9.60 kW
9.40 kW
SCOP
4.88
3.59
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.50 kW
8.30 kW
COP Tj = -7°C
2.93
2.17
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
5.50 kW
5.10 kW
COP Tj = +2°C
4.61
3.42
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
3.70 kW
3.40 kW
COP Tj = +7°C
7.01
5.10
Cdh Tj = +7 °C
0.958
0.967
Pdh Tj = 12°C
4.40 kW
4.30 kW
COP Tj = 12°C
9.33
5.93
Cdh Tj = +12 °C
0.953
0.970
Pdh Tj = Tbiv
8.50 kW
8.30 kW
COP Tj = Tbiv
2.93
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.10 kW
7.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.90
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
68 °C
68 °C
Poff
22 W
22 W
PTO
22 W
22 W
PSB
22 W
22 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.50 kW
1.60 kW
Annual energy consumption Qhe
4069 kWh
5410 kWh