0,760 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.60 kW
9.40 kW
El input
2.21 kW
3.19 kW
COP
4.35
2.95
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
El input
2.55 kW
Cooling capacity
7.40
EER
2.90
EN 14825
+7°C/+12°C
Pdesignc
7.40 kW
SEER
5.15
Pdc Tj = 35°C
7.40 kW
EER Tj = 35°C
2.90
Cdc Tj = 35 °C
Pdc Tj = 30°C
5.45 kW
EER Tj = 30°C
4.23
Cdc Tj = 30 °C
Pdc Tj = 25°C
3.51 kW
EER Tj = 25°C
6.10
Cdc Tj = 25 °C
Pdc Tj = 20°C
3.02 kW
EER Tj = 20°C
7.54
Cdc Tj = 20 °C
0.963
Poff
10 W
PTO
15 W
PSB
10 W
PCK
0 W
Annual energy consumption Qce
4440 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
49 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
185 %
131 %
Prated
6.43 kW
6.45 kW
SCOP
4.69
3.34
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.69 kW
5.71 kW
COP Tj = -7°C
2.68
1.90
Cdh Tj = -7 °C
Pdh Tj = +2°C
3.46 kW
3.48 kW
COP Tj = +2°C
4.60
3.12
Cdh Tj = +2 °C
Pdh Tj = +7°C
2.80 kW
2.68 kW
COP Tj = +7°C
6.63
4.97
Cdh Tj = +7 °C
0.964
0.972
Pdh Tj = 12°C
3.23 kW
3.16 kW
COP Tj = 12°C
8.51
7.09
Cdh Tj = +12 °C
0.960
0.966
Pdh Tj = Tbiv
5.69 kW
5.71 kW
COP Tj = Tbiv
2.68
1.90
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.27 kW
5.29 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.36
1.71
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
15 W
15 W
PSB
10 W
10 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
1.16 kW
1.16 kW
Annual energy consumption Qhe
2829 kWh
3989 kWh